Manuale d’uso / di manutenzione del prodotto UNIVERSAL COOK'N'VENT del fabbricante Thermador
Vai alla pagina of 16
For Integral Blower Installations: • Requires Integral Blower: Model # VTN600CVA • Requires Round Duct Size (6" Diam.) • Requires Dedicated Branch Cir cuit P ow er Supply • 120 V olt A C• min.
SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS A . Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-related construction.
Figure 1 Snorkel Filters Suppor t Leg J-Box T op Cap Blower Assembly Wing Nuts INTRODUCTION GENERAL DESCRIPTION The complete Universal Cook‘n‘Vent ® System consists of the ventilator intake and a blower .
STEP 1 PLAN THE INSTALLATION Carefully follow the planning procedures listed below. See Figure 2. A . Determine whether a remote or integral blower will be used. Remote blower installation requires 5 wires plus a ground wire to run from the Cook‘n’Vent ® to the blower.
Figure 2 • Be certain to avoid interference with gas and electric supply to cooktop . • Shelving and dra w er depths are dependent upon cooktop depth and setback.
FIGURES 3 THR OUGH 6 ARE EXAMPLES OF POSSIBLE DUCTING Figure 3 THROUGH W ALL INST ALLA TION Figure 4 INTEGRAL BLO WER VTN600CVA Ground 12" Min. Wall Cap WC8 Figure 5 THROUGH WALL DUCT INSTALLATIO.
Page 6.
T ABLE 2. DUCT W ORK INST ALLA TION GUIDELINES • Keep duct runs as short and straight as possible. • Duct fittings (elbows and transitions) reduce air flow efficiency. • Back to back elbows and "S" turns significantly reduces air flow and are not recommended.
Figure 7 TABLE 3 (in inches) UCV30/36/45 INSTALLATION DIMENSIONS WITH THERMADOR COOKTOPS Table 3 Notes * Dimension "SB" is the minimum distance from the leading edge of the counter to the leading edge of the cutout.
I NSTALLATION WITH OTHER COOKTOPS WHERE SPECIFIED (SEE PART B) Figure 8 34-1/2" - UCV36 OW CW 28-1/2" - UCV30 1/8" OD CD SB 2-1/4" BT 43-1/2" - UCV45 The installer will need to have the cooktop installation instructions available to complete the installation.
STEP 3 PREPARE DUCT CUTOUTS IN CABINET T ABLE 4 INTEGRAL BLOWER VTN600CVA C D E F G H UCV30 7-1/2 6 1/ 4 15-1/2 9 - UCV36 7-1/2 6 1/ 4 15-1/2 9 - UCV45 7-1/2 6 1/ 4 15-1/2 9 - REMOTE BLOWER VTR600R OR VTR1000Q C D E F G H UCV30 7-1/4 6 - 12-1/4 12-1/4 3 UCV36 7-1/4 6 - 12-1/4 12-1/4 3 UCV45 7-1/4 6 - 12-1/4 12-1/4 3 Page 10 A .
STEP 6 MOUNT VENT & COOKT OP A. Remove grease filters and any packing materials from inside the intake. B. Set the vent intake into rear of countertop opening. Carefully lower it into position so that the flanges on the rear sides and edges fully support the unit hanging from the countertop.
STEP 7 MOUNT INTEGRAL BLOWER OR Remote Blower Transition MOUNT INTEGRAL BLOWER OR Remote Blower Transition Integral Blower VTN600CVA Only A. Place blower in front of intake inside of cabinet, take conduit and blower wires and guide them towards the right at the floor of the cabinet.
STEP 8 VERIFY INSTALLATION, OPERA TION & COOKT OP ALIGNMENT Before performing this procedure, verify that all packing materials were removed from inside the lower enclosure front and that the grease filters have been properly installed. Refer to the Care and Use Manual for instructions regarding filter instal- lation.
NO TES.
5551 McFadden Aven ue, Huntington Beach C A, 92649 • 800-735-4328 BSH Home Appliances Corp. • Litho in U.S.A. 10/02 5060004249 (8209).
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Thermador UNIVERSAL COOK'N'VENT è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Thermador UNIVERSAL COOK'N'VENT - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Thermador UNIVERSAL COOK'N'VENT imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Thermador UNIVERSAL COOK'N'VENT ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Thermador UNIVERSAL COOK'N'VENT, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Thermador UNIVERSAL COOK'N'VENT.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Thermador UNIVERSAL COOK'N'VENT. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Thermador UNIVERSAL COOK'N'VENT insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.