21 Stand LCD Display Function keys WEATHER STATION Instruction Manual INTRODUCTION: Congratulation s on purchasi ng this sta te-of-the-ar t weather station as an example of inn ovative de sign and quali ty piece o f engineerin g.
22 • Temperatu re display in ºC/ ºF • Indoor and outdoor tempe rature displa y with MIN/ MAX reco rds and time of reception • Humidity dat a display as R H% • Indoor and outdoor humidit y di.
23 TO INSTALL A ND REPLACE BAT TERIES IN THE THERMO-HYGR O TRANSMITTER The outdoo r Thermo-h ygro transmitter uses 2 x AA IEC LR6, 1.5V batteries. T o install a nd replace t he batteries , please foll ow the steps belo w: 1. Remove th e battery cov er at the front si de with a sm all screwdriver.
24 between the W eather Sta tion and the transmitter s hould not be more than 100 meters (s ee notes o n “ Positionin g” and “86 8 MHz Rec eption ”). Note: In the event of changing b atteries of th e units, ensur e the batteri es do not sp ring free from the c ontacts.
25 8. In order to ens ure sufficie nt 868 MHz tr ansmission h owever, the distance between the W eather Sta tion and the transmitter s hould not be more than 100 meters (s ee notes o n “ Positionin g” and “86 8 MHz Rec eption ”).
26 IN key OUT/+ key SET key CH key • W ithin ferro-concrete room s (basemen ts, supe rstructures), th e received signal is nat urally weak ened. In extrem e cases, ple ase place the unit close to a windo w and/ or point its front or ba ck towards t he Frankfu rt transmitter.
27 Weather tendency indicator Calendar Indoor relative humidity in RH% Time reception icon (for DCF time) Indoor temperature in ºC/ ºF Weather forecast icon Outdoor data signal reception indicator *.
28 LCD CONTRA ST SETTING: The LCD co ntrast can b e set within 8 le vels, from L CD 0 to LCD 7 (Default s etting is LCD 4): 1. Press and h old the SET key until the di git starts flas hing. 2. Use the OUT /+ key to vie w all levels of contrast. 3. Select the d esired LCD c ontrast.
29 The hour dis play can be sel ected to s how hours in 12-hour o r 24-hour setti ngs. (Default 24-Ho ur) 1. Use the OUT/+ key to t oggle betwee n “12H” or “24H”.
30 5. Press the SE T ke y again to c onfirm and to enter the d ate setting m ode. The date sta rts flashing. 6. Use the OUT /+ key to se t the date. 7.
31 WE A T HER FORECASTING ICON SENSITIVITY SETTING: For locations with rapid c hanges of weather conditio ns, the weather icons sensitivity can be set to a di fferent level for faster dis play of weat her conditio ns. 1. The current se nsitivity val ue will start fl ashing.
32 Note: The MIN or MA X data needs to be reset indi vidually. WE A T HER FORECAST AND WEA THER TENDENCY: WE A T HER FORECASTING ICONS: W eather icons in the third section of LC D can be dis played in.
33 WE A T HER TENDENCY INDICA TOR W orking together with the weather icon s is the weat her tendenc y indicators (located on t he left and ri ght sides of th e weather icon s).
34 TOGGLING A ND RESETTING THE OUTDOOR DA TA 1. To toggle be tween the ou tdoor current, MAX/ MIN temperatu re and humidit y data and the times (for t emperature d ata onl y) they were recor ded press the OUT/+ k ey: Once to sho w the MA X outdoor temper ature and hum idity data with the recorded tim e and date.
35 CHECKING FOR 868 MHz RECEPTION If the outdoo r temperatur e and humidit y data are not being r eceived withi n three minutes after setting up (o r outdoor dis play al ways show “- -. - ” in the out door section of the W eather st ation during normal operati on), please c heck the following poi nts: 1.
36 The foldout t able stand le g is located o n the back side. Pull the stand out from t he bottom c enter edge of the weathe r station, below the batt ery compartm ent. Once t he foldout ta ble stand is extended, pl ace the weather station in an app ropriate location.
37 SPECIFICAT IONS: Recommende d operating t emperature r ange: 0ºC t o 50ºC Temperature measurin g range: Indoor : -9.9ºC to +59. 9ºC with 0.1 °C resoluti on 14.2ºF to 139. 8ºF with 0. 2ºF resolutio n (“OF.L” displ ayed if outside this range) Outdoor : -39.
38 • The manufac turer and sup plier cann ot accept an y responsibilit y for any incorrect rea dings and an y consequenc es that occ ur should an i naccurate reading take place. • This product is not to be us ed for medic al purposes o r for public information.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il TFA 35.1078.10.IT è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del TFA 35.1078.10.IT - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso TFA 35.1078.10.IT imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul TFA 35.1078.10.IT ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il TFA 35.1078.10.IT, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del TFA 35.1078.10.IT.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il TFA 35.1078.10.IT. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo TFA 35.1078.10.IT insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.