Manuale d’uso / di manutenzione del prodotto SMP del fabbricante Telex
Vai alla pagina of 28
T elex ® Op er at ing In struc tions RadioCom TM FM-1 QSB-1 SMP Pro fes sional Wire less In ter com Sys tem Man age ment.
T a ble of Con tent -i- Sec tion 1 In tr o duc tion ........................................................... 1-1 Over all De scrip tion ............................................................ 1-1 Sec tion 2 Sys tem Man ager Pr o gram ( SMP ) Soft war e .
-ii- Blank.
Sec tion 1 In tro duc tion Over all De scrip tion The SMP Soft ware along with t he QSB-1 and FM -1 al low a user to eas ily man age large sys tems of BTR-1 base sta tions along with thei r beltpac ks. The SMP (Sys tem Man ager Pr o gram ) soft ware en ables a user to set-up m ul ti ple events on the com puter .
1-2 Blank.
Sec tion 2 Sys tem Man ager Pro gram ( SMP ) Soft ware Sys tem Man ager Pro gram (SMP) In stall ing the Pr o gram (S tep 1) 1 . In sert the Man ual/ SMP Pro gram com pact disc int o your CD-ROM driv e. The pr o gr am will au to mat i cally start. 2. Se lect the "Sys tem Man ager Pro gram" but ton.
Launch ing the Sys tem Man ager Pr o gram (S tep 3) 1. Click on t he com puter desk top icon, shown to the right , to launch the pro gram. 2. The fol low ing Screen will then a p pear: Fig ur e 2-1 The main screen of the sys tem man ager pr o gram.
Us ing the Sys tem Man ager Pro gram The main s creen dis plays the 10 base sta tions. 1. Event Name. 2. Base Name – A 10 ch ar ac ter name for the b ase is dis - played here . The nam e is en tered in the con fig u ra tion screens. 3 . The Band Des ig na tion – Base 1, shown here, i s a F1 base sta tion .
HELP: About: Pro vides cur rent soft ware ver sion in for - ma tion. Con fig u ra tion But ton This but ton cre ates the con fig u ra tion of the se lected BTR-1 and TR-1 .
8. Sidetone - The sidet one is the a mount of a user ’ s own voice that is feed bac k to their head phones. Both t he beltpack a nd base sta tions sidetone m y be ad justed. 9. T rans mit Powe r - The base trans mit power can be set to the fol low ing po si tions: Normal = The trans mit power is 10 dB be low max i - mum power .
Down loading / Up loading Af ter an event is set -up it m ay be down loaded to a DataFlash ® card for the even tual down loading into a FM-1 and thus to a sys tem of up to 10 base st a tions.
Sec tion 3 QSB-1 QSB-1 The QSB-1 ( Qard Se rial Bus) p od in ter faces with the SMP (Sys tem Man ager Pro gram) via a USB con nec tion to the com - - puter . The QSB-1 al lows the user to down load events int o a small , con ve nient, DataFlash ® mem ory card.
3-2 Blank.
Sec tion 4 FM-1 Fr e quency Man ager Fr ont Panel Con trols and Con nec tions 1. Power Switch. 2. <MENU> and <SET> but tons – Used to se lect menus and set op tions on the LCD. 3. Backlit Gra phics LCD (Liq uid C rys tal Dis play ) . 4. <UP> and <SET> but tons – Used to se lect op tions on the LCD.
Figur e4-3 CAN Bus OUT RJ-45 Pinout Op er a tion Ba sic De scrip tion The FM-1 (Fre quency Man ager) in ter faces with up to ten BTR-1 base sta tions. The FM-1 t alks to the bas es via a CAN bus sys tem. The C AN bus starts at the FM-1 and daisy chains through all the ba se sta tions and then bac k to the FM-1 to t er - - mi nate.
Downloading a Card The fol low ing steps download a card t o the FM-1. 1. From the event screen press <MENU> o nce to ar rive at the down load card / se lect event menu screen. 2. Se lect down load card with the <UP>/<DOWN> ar row buttons and press <S ET> to go to the down load screen.
4-4 Blank.
Sec tion 5 FM-1 Menu S truc tur e 5-1 Fig ur e 5-1 FM-1 Menu Flow Chart.
5-2 Blank.
Sec tion 6 Soft war e Li cen se 6-1 End-User Li cense Agree ment fo r T elex ® Soft war e IM POR T ANT - Ple ase red this doc u ment care fully be fore us ing this prod uct. THIS DOC U MENT ST A TES THE TERMS AND CON DI TIONS UPON WHICH TELEX COM MU NI CA - - TIONS, INC.
6-2 Blank.
Sec tion 7 DataFlash ® Card Han dling and S tor age Pre cau tions 7-1 • Do not dis as sem ble or re model • Keep out of reach of chil dren. Dan ger of swal low ing.
7-2 Blank.
Sec tion 8 Fr e quency Bands Fr e quency Bands The BTR-1 sys tem op er ates in TV chan nels 16 to 36 and 38 to 59. This is the f re quency range of 482 to 608 MHz and 614 MHz to 746 MHz. The band, the TV chan nels and fre quen cies are shown in T a ble 2.
8-2 Blank.
Sec tion 9 Re place ment Parts and Ac ces so ries QSB-1 Card Reader P/N 879845 USB Ca ble P/N 600091 2 MB DataFlash ® Mem ory Card P/N 760600 QSB-1 Kit In cludes: QSB-1 Card Reader USB Ca ble DataFlash ® Card Cat No.
9-2 Blank.
TELEX COM MU NI CA TIONS, INC. • 12000 Port land A ve. South, Burnsville, MN 55337. PN 803996 REV B MARCH 2005 Made in U.S.A..
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Telex SMP è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Telex SMP - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Telex SMP imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Telex SMP ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Telex SMP, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Telex SMP.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Telex SMP. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Telex SMP insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.