Manuale d’uso / di manutenzione del prodotto iQM Series del fabbricante TDK
Vai alla pagina of 15
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 1/15 Supere ta™ iQ M Seri es DC/DC Pow er Mo dules 48V Input, 1.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 2/15 Ordering infor mation: Product Ident.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 3/15 Mechanical Sp ecifica tion : Dimensions are in mm [in]. Unless otherwise specified to lerances are: x.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 4/15 A bsolute Maximum Ratings : Stress in excess of Absolute Maximum Ratings may caus e per manent dam age to the device.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 5/15 Electrical D ata: iQM48070 A015V-000 through -009: 1.5 V, 70 A Output Characteri stic Mi n Ty p M ax Unit Notes & Conditions Output Voltage Initial Set point 1.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 6/15 Electrical C haracte ristics: iQ M 48070A015V-000 thro ugh -009: 1.5V, 70 A Output Efficienc y vs.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 7/15 Electrical Ch aracteris tics (continued) : iQ M 48070A015V-000 thro ugh -009: 1.5V, 70 A Output Output Current Li m it Characteristics vs.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 8/15 Thermal Performance: iQM48070 A015V-000 thro ugh -009: 1.5V, 70 A Output Maximum output current vs .
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 9/15 Wind Tunnel Test Setup Figure Dimensions are in millimeters and (inches).
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 10/15 perform ance page f or the po wer module of interest.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 11/15 Operating Informatio n: Over-Curre nt Protection: The po wer modules have curr ent lim it protection t o protect th e module during o utput over load and shor t circuit co nditions.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 12/15 Vin(-) On/ Off Vin (+) On/Off Circu.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 13/15 Sense(+) Trim Vout(-) Sense(-) Vout.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 14/15 nominal input, f ull load, an d T a = 40 ˚ C using the Telc ordia T R-332 issu e 6 calc ulation method.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 15/15 Safety Con sideration s: For saf et.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il TDK iQM Series è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del TDK iQM Series - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso TDK iQM Series imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul TDK iQM Series ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il TDK iQM Series, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del TDK iQM Series.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il TDK iQM Series. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo TDK iQM Series insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.