C M Y CM MY CY CMY K Owners Manual VNET 12, VNET 12 HP, VNET 15, VNET 300 VNET 15 HL, VNET 15BP & VNET 18DR TM.
C M Y CM MY CY CMY K 2 1.0: IMPORTANT SAFETY INSTRUCTIONS 2.0: INTRODUCTION 3.0: THE BASICS 3.1 Unpacking and visual checks 3.2 Preliminary recommendation 4.0: INTERF ACE P ANEL 5.0: OPERATION 5.1: AC power requirements 5.2 Cooling 5.3 LED functions 5.
C M Y CM MY CY CMY K TM 3 1.0: IMPORT ANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS 1 Read these instructions. 2 Keep these instructions. 3 Heed all warnings. 4 Follow all instructions. 5 Do not use this apparatus near water . 6 Clean only with dry cloth.
C M Y CM MY CY CMY K 4 INSTALLATION INSTRUCTIONS 1 THIS PRODUCT MUST BE EARTHED. Use only a flexible cable or cord provided with a green or green and yellow core which must be connected to the protective earthing terminal of the detachable Neutrik ’Powercon’ type NEC3FCA connector (T annoy part number 3461 0919 as supplied with the equipment.
C M Y CM MY CY CMY K 5 2.0: INTRODUCTION The T annoy VNET12HP & VNET15 loudspeakers utilise high performance Dual Concentric“ drive units — the 12 (300mm) PowerDual“ and the 15 (380mm) PowerDual“.
C M Y CM MY CY CMY K CM I N T E R T E K L I S T E D C US THIS CLASS D DIGITAL DEVICE MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULATIONS AND COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION SUBJECT TO CONDITIONS ST ATED IN THE MANUAL.
C M Y CM MY CY CMY K 7 TM 5.1: AC POWER REQUIREMENTS AC Power Requirements VNET“ products are equipped with Neutrik Powercon“ mains connectors which mate with the Neutrik NAC3FCA Cable connector , quick lock with a securing lever for power-in. This AC mains connector is supplied with each VNET“ product.
C M Y CM MY CY CMY K 6.0: NETWORK CONNECTIONS Interconnection between the network computer and the speakers is very straight forward, using twisted pair cable and simple connectors.
C M Y CM MY CY CMY K 9 4.5: USER DSP ON/OFF Connections from the RS485 device to the speaker is as follows:- From RS485 Device RJ45 To Vnet Network B+ Pin 1 A - Pin 2 GND Pin 5 Network connections between nodes are via rugged Neutrik ethercon connectors; these are high quality and are compatible with standard RJ45 plugs.
C M Y CM MY CY CMY K 7.0 SOFTW ARE INST ALLA TION Y ou can check to see if you already have the .NET Framework 1.1 installed by clicking Start on your Windows desktop, selecting Control Panel , and then double-clicking the Add or Remove Programs icon.
C M Y CM MY CY CMY K 11 7.0 SOFTW ARE INST ALLA TION TM 3. Confirm Installation. Click <Next> 4. If you accept the licence agreement check I Agree and Click <Next> 5.
C M Y CM MY CY CMY K 8.0 SOFTW ARE OPERA TION 12 Menus The menu system is arranged like so: File Open opens a file which contains parameters for the device Save saves the current settings in the curre.
C M Y CM MY CY CMY K 13 TM PodW are communicates with VNET“ using a serial COM port as a network connection. When a network connection is open and actively connected to a compatible device, the system is said to be On Line .
C M Y CM MY CY CMY K 8.0 SOFTW ARE OPERA TION 14 The control panel shows the model name (not editable), and firmware version for the device. The device properties panel also have an editable Configuration Name, and Loudspeaker name, the latter will appear in the tree menu after editing.
C M Y CM MY CY CMY K SPEAKER PROPERTIES At the top of the panel there are several pieces of information about the connected device (which are only activated when going On-line to a device): ˚ Model Name The VNET“ model number Loudspeaker name T o uniquely identify the speaker (i.
C M Y CM MY CY CMY K 7.0 SOFTW ARE OPERA TION Audio Processing VNET“ provides the following processing options: •• Crossover filtering with frequency variable over the range 10Hz to 25kHz (and O.
C M Y CM MY CY CMY K 7.0 SOFTW ARE OPERA TION ˚ Smooth adjustment Whenever a parameter is changed, VNET“ will assess the likely impact on the signal path, and will intelligently smoothly ramp to the new value, or mute for a short time if the change could otherwise cause any undesirable sound to be reproduced.
C M Y CM MY CY CMY K 18 8.1: UPDA TING FIRMW ARE 8. At the bottom right hand side of the screen a blue bar will show the progress of the firmware update. 9. After the download is complete the following message appears. The DSP is updating at this point.
C M Y CM MY CY CMY K 19 TM 9.0: EQUALISA TION VNET“ loudspeakers are designed to need no equalisation or correction to overcome system limitations. As a result, they will only need equalisation to compensate for difficult acoustic environments.
C M Y CM MY CY CMY K 20 1 1.0 DIMENSIONS VNET 12 & 12HP 180.0 290.0 370.0 175.0 360.0 30 ∞ 50 ∞ 486.0 40.0 406.0 153.0 180.0 175.0 CM I N T E R T E K L I S T E D C US 115-230V 50-60Hz 1000VA T.
C M Y CM MY CY CMY K 2 1 TM 1 1.0 DIMENSIONS 555.0 290.0 43.0 667.0 710. 652.4 290.0 43.0 609.4 THIS EQUIPMENT MUST BE EARTHED LINK NETWORK IN NETWORK LINK INPUT ON - OFF USER DSP T10AL 250V POWER FUSE - POWER - SIGNAL - LIMIT MANUFACTURED IN THE UNITED KINGDOM CAUTION OUVRIR.
C M Y CM MY CY CMY K 2 2 12.0 PERFORMANCE DA T A VNET12 Anechoic Frequency Response VNET12 HP Anechoic Frequency Response VNET300 Anechoic Frequency Response VNET15 Anechoic Frequency Response.
C M Y CM MY CY CMY K TM 13.0: TECHNICAL SPECIFICA TIONS SYSTEM V NET 12 V NET 12HP V NET 15 V NET 300 System Type Full Range - V ented Full Range - V ented Full Range - V ented Full Range — V ented .
C M Y CM MY CY CMY K 24 SYSTEM V NET 15BP V NET 15HL V NET 18DR System Type Subwoofer - Band Pass Full Range — Horn Loaded Full Range — Direct Radiating Frequency Response (1) +/- 3dB 35Hz - 150Hz.
C M Y CM MY CY CMY K TM 14.0: RIGGING The T annoy Professional hardware covered in this guide has been designed to offer quick, simple, cost effective and secure solutions for mounting specific T annoy Professional loudspeakers. This hardware has been designed and manufactured with a high safety load factor for its specific role.
C M Y CM MY CY CMY K 26 Use the table of parts along with the assembly drawing (Figure 3.) to assemble the VMY . Figure 4 shows the VMY assembled. Fig.
C M Y CM MY CY CMY K 27 TM 14.2 : SECUR ET - V15Y & V12Y V15Y V12Y.
C M Y CM MY CY CMY K 28 14.3 : SECUR ET - VMB W ALL MOUNTING BRACKET FIG 1. The VMB is wall mounting bracket for the attachment of a VMY , available in both black and white finishes, allowing the user secure the T annoy VNET“ Full range loudspeaker in either portrait or landscape orientations to a wall.
C M Y CM MY CY CMY K 29 TM 14.4 : SECUR ET - VEB EYEBOL T The T annoy VNET“ loudspeaker can be flown with high quality VEB M10 eyebolts with collar to BS4278:1984. The loudspeakers are equipped with internal steel braces, which also double as the flying points, and accept VEB M10 eyebolts.
C M Y CM MY CY CMY K 30 14.5 : SECUR ET - VTH POLE MOUNT The T annoy VNET“ loudspeakers are fitted as standard with a blanking plate on the base of the cabinet. However , should you ever wish to mount the VNET“ onto a standard 35mm pole mount this blanking plate can be quickly and easily removed and replaced by a VTH pole mount.
C M Y CM MY CY CMY K 31 TM 15.0: SERVICE P ARTS & ACCESSORIES Full Range VNET Amplifier & DSP Module 7300 1045 Duals 7300 1062 Subs VNET12 7900 0433 Driver Kit - 3142 7900 0441 Recone Kit - 31.
C M Y CM MY CY CMY K 16.0: W ARRANTY No maintenance of the VNET“ loudspeakers is necessary. All T annoy professional loudspeaker products are covered by a 5 year warranty from the date of manufacture (1 year for electronics), subject to the absence of misuse, overload or accidental damage.
C M Y CM MY CY CMY K TM 18.0: NOTES.
C M Y CM MY CY CMY K NOTES.
C M Y CM MY CY CMY K TM NOTES.
C M Y CM MY CY CMY K 6481 0470 / 0508 Tannoy adopts a policy of continuous improvement and product specification is subject to change. Tannoy United Kingdom T: +44 (0) 1236 420199 F: +44 (0) 1236 428230 E: enquiries@tannoy.com Tannoy North America T: (519) 745 1158 F: (519) 745 2364 E: inquiries@tannoyna.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Tannoy 18DR è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Tannoy 18DR - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Tannoy 18DR imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Tannoy 18DR ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Tannoy 18DR, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Tannoy 18DR.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Tannoy 18DR. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Tannoy 18DR insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.