Manuale d’uso / di manutenzione del prodotto D1320202 del fabbricante TANDBERG
Vai alla pagina of 32
TANDBERG GW Data port Comm and Interfac e User G uide 1 T ANDBERG 3G GW Data port Command Interface User Guide Softwar e version R2 D1320202 TANDBERG.
TANDBERG GW Data port Comm and Interfac e User G uide 2 Table of Contents 1. INTRODUCTION ................................................................................................................... ........ 3 2. CONNECTIN G TO THE DATA PORT C OMMAND INTERFACE THROUGH T HE RS- 232 PORT.
TANDBERG GW Data port Comm and Interfac e User G uide 3 1. Introduction The TANDBERG GW Data port Command Interface User Guide contains guidelines on how to use the textual command interface supported by the GW.
TANDBERG GW Data port Comm and Interfac e User G uide 4 2. Connecting to the Data port Command Interface through the RS-232 port. The RS-232 port is a 9-pin, fem ale, D-sub connector located on the front of the GW. The port is configured as a DCE (Data Communications Equipment).
TANDBERG GW Data port Comm and Interfac e User G uide 5 2.2. Troubleshooting If communication cannot be established between the PC/terminal and the TANDBERG GW’s Data port the following should be ch.
TANDBERG GW Data port Comm and Interfac e User G uide 6 3. Connecting to the Data port Co mmand Interface using Telnet The TANDBERG 3GW has one LAN port. The GW’s Telnet server provides access to the Data port Command Interface through a 10/100 base T network interface supporting the TCP/ IP protocol.
TANDBERG GW Data port Comm and Interfac e User G uide 7 4. The TANDBERG 3G Gateway Commands 4.1. Introduction Typing ‘ ? ’ or ‘ help ’ when connected to the Data Port Command Interface will return a list of valid commands. The commands are used to control the functions of the 3G Gateway.
TANDBERG GW Data port Comm and Interfac e User G uide 8 • User Commands, Xcom. Parameter Configuration Commands are commands that set a system parameter to a specific value. E.g.: The command Xconf telnet mode: "on" enables telnet access on the gateway.
TANDBERG GW Data port Comm and Interfac e User G uide 9 4.2.1. System Configuration Commands Command: Description: H323Gatekeeper Sets gatekeeper parameters.
TANDBERG GW Data port Comm and Interfac e User G uide 10 • DNS Server: Num ber identify ing one of 5 DNS serve rs which can be configured. If this parameter is omitted th e command applies to the first configuratio n (1). sub-co mmands: • Assignment : Selects between DHCP (Dynamic Host Configuratio n Protocol) or static IP address allocation.
TANDBERG GW Data port Comm and Interfac e User G uide 11 Within ISDN different bearer cap abilities are used to signal the type of d ate (Voice, Data, H32 0, H324M), whic h is used by switches and other equipment to determine what to do with the data or the call (compand neglect etc).
TANDBERG GW Data port Comm and Interfac e User G uide 12 SNMP SystemLoca tion: <S: 0, 70> or SNMP HostIPAddr [1..3]: < IPAddr> --- parameters: • Mode: < On/Off/ReadOnly/TrapsOnly > • Community Name: Text st ring of m aximum 16 characters.
TANDBERG GW Data port Comm and Interfac e User G uide 13 sub-co mmands • Name, sets the name of the 3G Gateway • Password, sets the password of the 3G gateway Example of SystemUnit fee dback: *c x.
TANDBERG GW Data port Comm and Interfac e User G uide 14 4.2.2. General GW Commands Command: Description: Gateway This command is used to co nfigure th e 3G gateway dialling rules, like for example direct inward dialli ng, H323 call prefixes and di al in numbers.
TANDBERG GW Data port Comm and Interfac e User G uide 15 Example of Gateway feedback: *c xConfigurat ion Gateway Servi ce 1 Description: "" *c xConfigurat ion Gateway Service 1 Servic eType:.
TANDBERG GW Data port Comm and Interfac e User G uide 16 NOTE! The GW needs to reboot before the chang es will take effect . Options [1 . . 64] Key: < S: 0, 90> --- sub-co mmands: • Key : Option key for e.
TANDBERG GW Data port Comm and Interfac e User G uide 17 LinkSet [1 .. 2] Link [1 . . 2] Timeslot: <1 .. 31> LinkSet [1 .. 2] Link [1 . . 2] SLC: <0 .. 15> Trunk [1 .. 4] Mode: <On/Off> Trunk [1 .. 4] DPC: <0 .. 16383> Trunk [1 .
TANDBERG GW Data port Comm and Interfac e User G uide 18 in the 3G Gateway User Manual. Example of SS7 feedback: *c xConfig uration S S7 OPC: 0 *c xConfigur ation SS7 NetworkIn dicator: N ational0 *c .
TANDBERG GW Data port Comm and Interfac e User G uide 19 *c xConfigur ation SS7 Trunk 3 M ode: Off *c xConfigur ation SS7 Trunk 3 DPC : 0 *c xConfiguration SS7 Trunk 3 CircuitIdentification Code: 0 *c.
TANDBERG GW Data port Comm and Interfac e User G uide 20 VideoPortal Registers the 3G Gateway with the VideoPortal NOTE! The GW needs to reboot before the chang es will take effect .
TANDBERG GW Data port Comm and Interfac e User G uide 21 4.2.3. System Status Commands Command: Description: SystemUnit Displays information reg arding the physical system SystemUnit Status format: &l.
TANDBERG GW Data port Comm and Interfac e User G uide 22 Telephony: 0 VideoTelephony: 0 Hardware: Version: "3GW 1.0" SerialNumber: "43A00001" MainBoar d: "" AdditionalBoa.
TANDBERG GW Data port Comm and Interfac e User G uide 23 • DNS Server [1.. 5] Addr ess , th e IP numb er s o f ma xi mu m 5 D NS servers • Domain , the name of the domain the gateway is part of. Example of IP feedback: * s IP: Address: "10.31.
TANDBERG GW Data port Comm and Interfac e User G uide 24 Example of Ex ternalManage r feedback: * s ExternalMana ger: Address: "" Protoc ol: HTTP URL: "t ms/public/ external/mana gement/SystemM anagement Service.asmx " *s/end BRI [1.
TANDBERG GW Data port Comm and Interfac e User G uide 25 Channel 15 (type=BChannel, status =Idle): / Channel 16 (type=DChannel, status=NA): / Channel 17 (type=BChannel, status =Idle): / Channel 18 (ty.
TANDBERG GW Data port Comm and Interfac e User G uide 26 Example of GatewayCa ll feedback: *s GatewayCall 1 (status=Inactive): / *s/end OK *s GatewayCall 1 (status=Active): CallRef 1: 1 CallRef 2: 2 *.
TANDBERG GW Data port Comm and Interfac e User G uide 27 LastCorrect ion: 1 *s/end 4.2.4. Debug Commands Command: Desription : Syslog Enables a real- time log o f Bonding , H.221 a nd H.323, H 324m, ISDN, R TSP, IVi der, SIP and IVi der Engine acti vity.
TANDBERG GW Data port Comm and Interfac e User G uide 28 feedback to 3 differe nt URLs. The sy stem allows a total of 20 XPath expressions to be registered, with a m aximum of 1 5 for a single URL. Parameters: • ID: <1 .. 3> ID for the registration.
TANDBERG GW Data port Comm and Interfac e User G uide 29 Example: Xcomma nd OptionKey Add 1152 01P1-1-6A 96DAA4 *r Result (status=OK): / *r/end OK OptionKeyDel ete Command used to delete option keys. Parameters: • Key(r): <S: 0, 90> opti on key Example (Delete Option Key nr .
TANDBERG GW Data port Comm and Interfac e User G uide 30 or: xfeedback list - (note: deregistration with index=0 will deregister all registered expressions) Examples : "xfeedback register status/.
TANDBERG GW Data port Comm and Interfac e User G uide 31.
TANDBERG GW Data port Comm and Interfac e User G uide 32 4.3. Index Commands boot, 27 BRI [1..4], 24 Call [1..90], 26 DefaultValuesSet, 27 E1, 11 Ethernet, 10 , 22 externalManager, 15 ExternalMana ger, 23 Feedback [1 3], 25 FeedbackDeregister, 28 FeedbackRegister, 27 , 29 Gateway, 14 GatewayCall [1.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il TANDBERG D1320202 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del TANDBERG D1320202 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso TANDBERG D1320202 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul TANDBERG D1320202 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il TANDBERG D1320202, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del TANDBERG D1320202.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il TANDBERG D1320202. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo TANDBERG D1320202 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.