Codian HD MCU MCU 4500 Series Getting started.
Codian MCU MCU 4500 Series Getting started.
Copy right © Codian 2008. All rights reser ved. This Getting Star ted Guide ma y not be copied, photocopied, translated, r eproduc ed, or con verted into any electronic or machine-readable form in whole or in par t without prior wr itten appro v al of Codian Limited.
T able of conten ts General inf ormation .......... .......... .......... ........... .......... .......... ............. .......... ........... .......... .. .... . 1 About the M ultipoint Cont rol Unit (M CU) ................... .......... .........
General information 1 General informa tion About the Multipoint Control Unit (MCU) The MCU 4500 Series is a range of tec hnolog ically ad vanced and po w erful Multipoint Contr ol Units. The y are designed to combine con tinuous presence a t high definition and the highest possible v oice quality .
2 LED beha vior T able 1 descr ibes the behavior of the LEDs . T able 1: MCU LED behavior LED Co lor Indicates Compact Flash Activity Flashing gr een One of: the MCU is booting a configuration.
LED behavior 3 Ethernet P or t Status, for each Ether net por t : FDX Green The link has been negotiated as a full- duplex link Act Green Pa c kets ar e being transmitted on this por t Link Green The .
4 Co nnecting the MCU Before you star t Step one: Connect power Connect the po w er connector on the rear of the unit to the pow er supply using the supplied po wer ca ble .
Initial configuration 5 Initial configur ation Step one: Connect to the console port 1 Ensure po wer is connected to the MCU and the Status LED is green. 2 Connect the console por t of the MCU to the serial por t of your PC using the blue RJ45 to DB9 cab le supplied.
6 T o configure Ether net P or t A, enter the follo wing for auto-sensing mode: ethertype auto or to configure a speed and duplex, use the follo wing command: ethertype <10|100> <half|ful.
Configuring the MCU 7 Co nfiguring the MCU Step one: Log in to the MCU All administration of the MCU is perfor med v ia the w eb interface. T o log in to the w eb interface of the MCU: 1 Use your bro wser to na vigate to the IP addr ess of the MCU (to disco ver the IP address, r efer to the pre vious section).
8 Step three: A dd endpoints (optional) One wa y to add par t icipants to a conference tha t you cr eate is to ha ve the MCU automaticall y call them when the conference star ts. T o do this, you configure their endpoints on the MCU. When you set up a conference , you can choose the endpoints from the P re- conf igured pa rticipants list.
Using the MCU 9 Usi n g t he M CU Creating conferences T o crea te a conference: 1 In the w eb interface of the MCU, go to Con fe re nc es and clic k Add new confer ence . 2T y p e a Name for the conference, for example SalesMeeting . 3 T ype an optional numeric identifier , for example 123 .
10 Calling partic ipants in to a conferenc e T o call par ticipants in to a conference: 1 In the w eb interface of the MCU, go to Conf er en ce s and clic k on the name of an active confer ence. 2O n t h e Pa r t ic i pa nt s tab , clic k Add partici pant to call out to an H.
Using the MCU 11 Streaming conferences Streaming is a wa y of viewing a conference in a standard w eb bro wser . The MCU allo ws streaming of video and, if enab led for a conference , the streaming of data. Y ou can also conduct a text ‘chat’ and add notes and dra wings to the data str eam.
12 Instruc ting confer ence par ticipants Y ou need to tell conference par ticipants ho w to join conferences . Y ou can also tell them ho w to use the Far-End Camera Contr o ls (FECC) to na vigate menus in the auto attendant and choose conference la youts.
Troubleshooting and tec hnical support information 13 T r oubleshooting and technical suppor t information Using the ev ent log to help solve a problem Unless you are ex periencing a prob lem, all e v ent logging sources should be set to the default, which is Errors, warnings and information .
14 T echnical specifications P ow er requiremen ts Over- current protection Ensure the suppl y to this unit is protected b y a branch circuit protector rated b y a maximum of 20A.
61-0011-05.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il TANDBERG 4500 Series è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del TANDBERG 4500 Series - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso TANDBERG 4500 Series imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul TANDBERG 4500 Series ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il TANDBERG 4500 Series, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del TANDBERG 4500 Series.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il TANDBERG 4500 Series. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo TANDBERG 4500 Series insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.