Manuale d’uso / di manutenzione del prodotto SY4100 del fabbricante Sylvania
Vai alla pagina of 28
Table of Contents WIRELESS HOME SECURITY SYSTEM OWNER’S MANUAL INSTALLATION AND O PERATION BEFORE INSTALLING OR OPERATING THE SYSTEM, PLEASE READ THIS MANUAL, MODEL: SY4100.
1 Introduction…………………………………………………………………………….…... System Package…………………………………………………………….…. Optional Accessories………………………………………………………….
2 • Read Instructions – All the safety and operating instructions should be read before operating this equi pment. These instructions should be retained for future reference • Heed Warnings – All warnings on the equipment and in the operating instructions should be adhered to.
3 Thank you for choosing the Sylvania ® SY4100 Wirel ess Home Security System. T he s e security systems are high - quality, reliable and versatile. This system has a built in Auto - dialer for increased security.
4 The security system is d esigned to be as flexible as possible in order to meet your present needs, and also to adapt as your needs change. For the reason, we recommend that you read and consider the following information and plan your system before installing these devices.
5 Connecting the Telephone Li ne To connect the Main Console to the telephone line, Please follow these steps: 1. Locate the two phone jacks at the top of the main console. These phone jacks are marked “ Phone “ and “ Line “. 2. Connect one end of the telephone cord that came with the sys tem into the connector, labeled” Line”.
6 The Main Console is the heart of the security system. It monitors the sensors a nd responds according to how it is programmed, whenever a sensor is activated. The illustration shown for the Main Console may look complex at first, however, most procedures are straightforward and easy.
7 13. Armed LED : W hen the light is ‘on’, the system is armed; When the light is ‘off’, the system is disarmed. 14. LCD Panel : Displays message s 15. Speaker : S ounds a larm and plays back messages 16. Antenna : Used for wireless reception 17.
8 3.1: System Option menu : P ress 0 to start setting (1) 0 - T : F or time setting (Default is 30 seconds.) minimum 1 second, maximum 255 seconds. Press the 0 button, to go to the time setting (exit, alarm, entry) time Press the 1 button, to set the delay time for exiting t he house.
9 Sett ing 5 : T he first priority dial in case of Fire. (check with the fire dept if this is a cceptable) Setting 6 : T he first priority dial in case of Medical help.
10 Press 1 to change the Install c ode menu. Press 2 to change the Master code menu. 3.2: Sequence Programming Menu This menu for code learning establishes a link between all sensors/other wireless devices and the main console.
11 7. If the sensor that was learnt into the main consol e is sending a signal during the learning mode, the main console will indicate on the LCD, as shown below and will not allow duplication. 8. If the sensor s “ learned ” reaches 63 zone numbers, the LCD panel will show a full message memory .
12 Press 1 , and key - in the sequence learning order number. P ress ENTER , to clear th e sensor. Press 2 , It will display the words “ Are you sure ? ”. P ress ENTER to clear all learned sensors. Function for Master Menu – F actory D efault P assword – 135246 1.
13 Now the system will select the arm mode and set the system in either Aw ay arm/Home Arm mode (see below ) : A - AWAY : P ress the A WAY button to set the “ Armed - Away “ alert. After the exit delay the Arm LED will illuminate steady and the system is armed in the AWAY mode.
14 l SP DIAL + 5 , the autodial order is: : Preset 5 : Preset 1 : Preset 2 : Preset 3 (Fire condition) l SP DIAL + 6 , the autodial order is: : Preset 6 : Preset 1 : Preset 2 : Preset 3 (Medical help .
15 LCD “MSG” : Message indicati ng on LCD This system will l eave a warning message on the LCD panel when the sensors are opened, triggered or in a low battery condition . It also emit s 3 short ‘Beeps’ every 10 Sec. to remind you of this. The first 5 messages can be displayed on the LCD .
16 The key chain Remote Control Handset is a convenient way to arm (Home / Away mode ) or disarm this system. Before using this device, please program it into the main console via the sequence programming menu. 1. TRANSMIT LED : The LE D will light when the device is transmitting 2.
17 The PIR Moti on Detector is designed to detect the movement of objects in a room or hallway. The effective range of the motion sensor is 30 feet long, with an 84degree horizontal angle. Before using this sensor, please program this sensor into the main console via the sequence programming menu .
18 Replace the Battery l When the sensor send s a low battery message to main console , remove the old battery and replace it with a fresh alkaline battery . T he LCD is shown below Zone A ddress S etting Enter the Installer password and press “1” to activate the “Sequence Programming Menu” after installing the battery for the PIR sensor .
19 To install the PIR Motion Sensor, please follow these steps : l Take out the screws or d ouble side d adhesive and install the mounting bracket on the wall . Press the ball joint portion into the bracket until it snaps securely. (Secure the mounting bracket on the wall, 2 meters above the floor ).
20 Change the Battery When the sensor send s a low battery message to the main console , remove the old battery and replace it with a fresh alkaline battery . T he low battery message on the LCD is shown below Zone address setting You can set the sensor as “ Door “ or “ Window “ detector by usi ng the jumper selector.
21 When the system is in the process of arming, and the sensor has been opened prior to the arming . (message shown on main console) • W indow opened • W indow battery cover opened Door battery cover opened I nstal ling the Door/Window Detector Installing for ( DC 12V Detector) : To install a Door/Window Detector, follow these steps: 1.
22 The siren is an effective deterrent to intruders. Choose a location inside your home where the siren is not plainly visible, but can be heard throughout the house. It is important to install the siren where the cable can be hidden, and discreetly out of reach of potential intruders (or anyone likely to tamper with the system.
23 Use the following form to record your programming choices for future reference. Item Descriptions Install Code Master C ode Exit Time Alarm Time Entry Time Auto - dialing Mode Preset Telephone No. for Auto - dialing : No. 1 Name Tel. No. No. 2 Name Tel.
24 Use the following form to record the setting detail of sensors Learning Number Place of Installation Zone Label Learning Number Place of Installation Zone Label 05 2F - xx room Window 1 Learning Nu.
25 Items Specifications Frequency - 303Mhz or 433Mhz Power Source - AC120V , DC 12V Power Consumption - 7 0mA (idle), 170mA (activated) Back - up Battery (Optional) - Approximate 7 hours ( NO AC adapt.
26 “Installation template for wall mounting of main control panel” 1. Use the template on the right to mark positions for mounting screws to install the main control panel on the wall. 2. Once the mounting screw positions have been marked, drill 3/16” p ilot holes and install the plastic wall anchors supplied.
27.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sylvania SY4100 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sylvania SY4100 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sylvania SY4100 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sylvania SY4100 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sylvania SY4100, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sylvania SY4100.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sylvania SY4100. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sylvania SY4100 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.