® S UPER S ER VER ® 6028R-TR 6028R-TR T S UPER USER’S MANUAL 1.0.
The information in this User ’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.
iii Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6028R-TR/TRT . Installation and maintainance should be performed by experienced technicians only .
S UPER S ERVER 6028R-TR/TRT User's Manual iv Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X10DRi-/X10DRi-T serverboard, including the locations and functions of connections, headers and jumpers.
Notes Preface v.
vi T able of Contents Chapter 1 Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Serverboard Features ..........................................................
vii NIC2 ................................................................................................................ 3-3 HDD ................................................................................................................. 3-3 Power .
viii S UPER S ERVER 6028R-TR/TRT User's Manual 5-8 Connector Denitions ................................................................................... 5-14 5-9 Jumper Settings ...............................................................
Chapter 1 Introduction 1-1 Overview The SuperServer 6028R-TR/TRT is a high-end server comprised of two main subsystems: the SC825TQ-R740LPB 2U chassis and the X10DRi-/X10DRi-T dual processor serverboard. Please refer to our web site for information on operating systems that have been certied for use with the system (www .
1-2 S UPER S ERVER 6028R-TR/TRT User's Manual 1-2 Serverboard Features The SuperServer 6028R-TR/TRT is built around the X10DRi-/X10DRi-T , a dual pro - cessor serverboard based on the Intel® PCH C612 chipset and designed to provide maximum performance.
1-3 Chapter 1: Introduction Graphics Controller The X10DRi-/X10DRi-T features an integrated Aspeed 2400 controller . 1-3 Server Chassis Features The SC825TQ-R740LPB is an A TX form factor chassis designed to be used in a 2U rackmount conguration. The following is a general outline of the main features of the SC825TQ-R740LPB server chassis.
1-4 S UPER S ERVER 6028R-TR/TRT User's Manual Figure 1-1. Chipset System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. SP I L AN 3 RGRMII Debug Card FRONT PANEL SYSTEM POWER CTRL FAN SPEED PCI-E X1 G2 USB 2.
1-5 Chapter 1: Introduction 1-4 Contacting Supermicro Headquarters Address: Super Micro Computer , Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. T el: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.
1-6 S UPER S ERVER 6028R-TR/TRT User's Manual Notes.
Chapter 2: Server Installation 2-1 Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your SuperServer 6028R-TR/ TRT up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time.
2-2 S UPER S ERVER 6028R-TR/TRT User's Manual • This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
Chapter 2: Server Installation 2-3 Rack Mounting Considerations Ambient Operating T emperature If installed in a closed or multi-unit rack assembly , the ambient operating tempera - ture of the rack environment may be greater than the ambient temperature of the room.
2-4 S UPER S ERVER 6028R-TR/TRT User's Manual 2-4 Installing the System into a Rack This section provides information on installing the SC825 chassis into a rack unit with the quick-release rails provided. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly .
Chapter 2: Server Installation 2-5 Figure 2-1: Separating the Rack Rails screw the handles the outer rails for secure purpose if necessary F. ABLECOM DA TE:2008/08/14 REV:2 SCREW SCREW COMPLETE 1 2 1 1 1 2 1 4 1 3 Separating the Inner and Outer Rails 1.
2-6 S UPER S ERVER 6028R-TR/TRT User's Manual Outer Rack Rails Outer rails attach to the rack and hold the chassis in place. The outer rails for the SC825 chassis extend between 30 inches and 33 inches. Installing the Outer Rails to the Rack 1. Secure the back end of the outer rail to the rack, using the screws provided.
Chapter 2: Server Installation 2-7 screw the handles the outer rails for secure purpose if necessary F. ABLECOM DA TE:2008/08/14 REV:2 SCREW SCREW COMPLETE 1 2 Figure 2-3. Installing the Rack Rails Installing the Chassis into a Rack 1. Extend the outer rails as illustrated above.
2-8 S UPER S ERVER 6028R-TR/TRT User's Manual Notes.
Chapter 3: System Interface 3-1 Chapter 3 System Interface 3-1 Overview There are several LEDs on the control panel as well as others on the drive carriers to keep you constantly informed of the overall status of the system and the activ - ity and health of specic components.
SUPERSERVER 6028R-TR/TR T User's Manual 3-2 Note: deactivating the UID LED must be performed in the same way it was activated. (If the UID LED was activated via IPMI, you can only turn the LED off via IPMI and not with the UID button.) Information LED States State Indication Continuously On (Red) An overheat condition has occured.
Chapter 3: System Interface 3-3 1 2 NIC1 Indicates network activity on the LAN1 port when ashing. NIC2 Indicates network activity on the LAN2 port when ashing. HDD This LED indicates hard drive and/or DVD-ROM drive activity when ashing. Power Indicates power is being supplied to the system's power supply units.
SUPERSERVER 6028R-TR/TR T User's Manual 3-4 Notes.
4-1 Chapter 4: W arning Statements for AC Systems Chapter 4 Standardized W arning Statements for AC Systems 4-1 About Standardized W arning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury .
4-2 S UPER S ERVER 6028R-TR/TRT User's Manual W arnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr . Sie benden sich in einer Situation, die zu V erletzungen führen kann.
4-3 W arning Statements for AC Systems 안전을 위한 주의사항 경고! 이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다.
4-4 S UPER S ERVER 6028R-TR/TRT User's Manual Installation Instructions W arning! Read the installation instructions before connecting the system to the power source. W arnung V or dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen.
4-5 Chapter 4: W arning Statements for AC Systems Circuit Breaker W arning! This product relies on the building's installation for short-circuit (overcurrent) protection.
4-6 S UPER S ERVER 6028R-TR/TRT User's Manual Power Disconnection W arning 電源切断の警告 システムコン ポ ー ネ ン トの 取り付 けまた は 取り外しの た め に 、 .
4-7 Chapter 4: W arning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema.
4-8 S UPER S ERVER 6028R-TR/TRT User's Manual Equipment Installation 機器の設置 ト レ ー ニ ン グを受け認 定さ れた人だけが こ の 装 置の 設 置、 交 換、 ま た.
4-9 Chapter 4: W arning Statements for AC Systems ア ク セ ス制限区域 こ の ユニ ッ ト は 、 ア ク セ ス制限区域 に 設置 さ れ る こ と を 想定 し て い ま す .
4-10 S UPER S ERVER 6028R-TR/TRT User's Manual Battery Handling W arning! There is the danger of explosion if the battery is replaced incorrectly .
4-1 1 Chapter 4: W arning Statements for AC Systems W arnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr . Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.
4-12 S UPER S ERVER 6028R-TR/TRT User's Manual W arnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle V erbindungen entfernt werden. ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación.
4-13 Chapter 4: W arning Statements for AC Systems Backplane V oltage バッ ク プレ ーン の 電 圧 シ ス テ ムの稼 働中 は危険な電 圧 ま たは電力 が、 バ ッ ク プ レ .
4-14 S UPER S ERVER 6028R-TR/TRT User's Manual Comply with Local and National Electrical Codes W arning! Installation of the equipment must comply with local and national electrical codes.
4-15 Chapter 4: W arning Statements for AC Systems Product Disposal W arning! Ultimate disposal of this product should be handled according to all national laws and regulations. יצראה למשחה יקוח םואית !הרהזא תנקתה םייצראהו םיימוקמה למשחה יקוחל תמאות תויהל תביי ח דויצה .
4-16 S UPER S ERVER 6028R-TR/TRT User's Manual W aarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales.
4-17 Chapter 4: W arning Statements for AC Systems W arnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger , Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
4-18 S UPER S ERVER 6028R-TR/TRT User's Manual W arning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors.
4-19 Chapter 4: W arning Statements for AC Systems Attention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné. L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie.
4-20 S UPER S ERVER 6028R-TR/TRT User's Manual Notes.
Chapter 5: Advanced Serverboard Setup 5-1 Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to connect the data and power cables and install add-on cards. All serverboard jumpers and connections are also described. A layout and quick reference chart are included in this chapter for your reference.
5-2 S UPER S ERVER 6028R-TR/TRT User's Manual Unpacking The serverboard is shipped in antistatic packaging to avoid electrical static dis - charge. When unpacking the board, make sure the person handling it is static protected. 5-2 Connecting Cables The cables listed below should already be connected to the serverboard.
Chapter 5: Advanced Serverboard Setup 5-3 5-3 I/O Ports See Figure 5-2 below for the descriptions of the various rear I/O ports. Figure 5-1. Control Panel Header Pins Figure 5-2. I/O Ports I/O Ports 1 COM1 Port 6 USB Port 13 (USB 3.0) 2 USB Port 0 (USB 2.
5-4 S UPER S ERVER 6028R-TR/TRT User's Manual 1. There are two levers on the LGA201 1 socket. First press and release the load lever labeled 'Open 1st'. 2. Press the second load lever labeled 'Close 1st' to release the load plate from its locked position.
Chapter 5: Advanced Serverboard Setup 5-5 Gently push down to pop the load plate open. 3. Wit h th e lever la be led ' Cl os e 1 st ' ful ly ret rac te d, gent ly pu sh do wn on th e 'O pe n 1st' l ever to op en t he loa d plate. L if t t he l oad p late to open it completely .
5-6 S UPER S ERVER 6028R-TR/TRT User's Manual W arning: Y ou can only install the CPU to the socket in one direction. Make sure that the CPU is properly inserted into the socket before closing the load plate. If it doesn't close properly , do not force it as it may damage your CPU.
Chapter 5: Advanced Serverboard Setup 5-7 1. Unplug the power cord from the power supply . 1. Unscrew and remove the heatsink screws in the sequence shown in the picture below . 2. Hold the heatsink and gently wiggle it to loosen it from the CPU. (Do not use excessive force when doing this!) 3.
5-8 S UPER S ERVER 6028R-TR/TRT User's Manual Memory Support The X10DRi/X10DRi-T supports up to 1 TB of DDR4-2133/1866/1600/1333 RDIMM ECC memory (or 2 TB of LRDIMMs). Use memory modules of the same type and speed. See the following tables for memory installation.
Chapter 5: Advanced Serverboard Setup 5-9 Processor & Memory Module Population Conguration For memor y to work properly , follow the tables below for memor y instal lation.
5-10 S UPER S ERVER 6028R-TR/TRT User's Manual 5-6 Adding PCI Add-On Cards The 6028R-TR/TRT can accommodate six low-prole PCI add-on cards. Installing an Add-on Card 1. Begin by removing the shield for the PCI slot you wish to populate. 2. Fully seat the card into the slot, pushing down with your thumbs evenly on both sides of the card.
Chapter 5: Advanced Serverboard Setup 5-1 1 Figure 5-4. X10DRi/X10DRi-T Layout (not drawn to scale) 5-7 Serverboard Details JPI2C1 JPWR1 JPWR2 JOH1 JL1 JSD1 JSD2 JSTBY1 JT PM 1 JPB1 JWD1 J29 JI2C2 JPME2 J30 JI2C1 USB3/4 (3.
5-12 S UPER S ERVER 6028R-TR/TRT User's Manual X10DRi/X10DRi-T Quick Reference Jumper Description Default Setting JBR1 BIOS Recovery Enable/Disable Pins 1-2 (Normal) JBT1 Clear CMOS See Section 5.
Chapter 5: Advanced Serverboard Setup 5-13 (CPU2) Slot5 PCI-Express 3.0 x8 Slot from CPU2 (CPU2) Slot6 PCI-Express 3.0 x16 Slot from CPU2 (T -)SGPIO1/2/3 Serial Link General Purpose I/O Headers SP1 Internal Speaker/Buzzer (BP) USB 0/1 Backpanel USB 2.
5-14 S UPER S ERVER 6028R-TR/TRT User's Manual Reset Button The Reset Button connection is located on pins 3 and 4 of JF1 and attaches to the reset switch on the computer chassis. See the table on the right for pin denitions. Power Button The Power On connection is on pins 1 and 2 of JF1.
Chapter 5: Advanced Serverboard Setup 5-15 HDD LED The HDD LED connection is located on pins 13 and 14 of JF1. Attach a cable to Pin 14 to show HDD activity status. Attach a cable to Pin 13 to use UID switch. See the table on the right for pin denitions.
5-16 S UPER S ERVER 6028R-TR/TRT User's Manual Fan Headers There are eight fan headers on the serverboard (Fan 1-Fan 6, Fan A, Fan B), all of which are 4 - p in fa ns. Pi ns 1-3 of t he fa n hea der s ar e bac k war d compatible wit h the traditional 3 - pin fans.
Chapter 5: Advanced Serverboard Setup 5-17 Internal Speaker The Internal Speaker , located at SP1, can be used to provide audible indica - tions for various beep codes. See the table on the right for pin denitions. Internal Buzzer (SP1) Pin Denition Pin# Denitions Pin 1 Pos.
5-18 S UPER S ERVER 6028R-TR/TRT User's Manual Standby Power The Standby Power header is located at JSTBY1 on the serverboard. See the table on the right for pin deni - tions.
Chapter 5: Advanced Serverboard Setup 5-19 Universal Serial Bus (USB) T wo USB 2.0 ports (USB 0/1) and two USB 2.0/3.0 ports (USB12/13) are lo - cated on the I/O backpanel. (Note that USB ports 12/13 support both USB 2.0 and 3.0.) In addition, two internal USB headers provides a total of four USB 2.
5-20 S UPER S ERVER 6028R-TR/TRT User's Manual 5-9 Jumper Settings Explanation of Jumpers T o modify the operation of the serverboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the con - nector .
Chapter 5: Advanced Serverboard Setup 5-21 CMOS Clear JBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS. T o clear CMOS, 1. First power down the system and unplug the power cord(s).
5-22 S UPER S ERVER 6028R-TR/TRT User's Manual I 2 C to PCI-E Slots Jumper Settings Jumper Setting Denition Pins 1-2 Enabled Pins 2-3 Disabled I 2 C Bus to PCI-Exp. Slots Jumpers JI 2 C1 and JI 2 C2 allow you to connect the System Management Bus (I 2 C) to the PCI-Express slots.
Chapter 5: Advanced Serverboard Setup 5-23 5-10 Onboard Indicators LAN LEDs The Ethernet ports (located beside the VGA port) have two LEDs. On each port, one LED ashes to indicate activ - ity while the other LED may be green, amber or off to indicate the speed of the connection.
5-24 S UPER S ERVER 6028R-TR/TRT User's Manual 5-1 1 SA T A Ports SA T A Port Pin Denitions Pin# Denition Pin Denition 1 Ground 2 TXP 3 TXN 4 Ground 5 RXN 6 RXP 7 Ground SA T A 3.
Chapter 5: Advanced Serverboard Setup 5-25 5-12 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com . Some of these must be installed, such as the chipset driver . After accessing the ftp site, go into the CDR_Images directory and locate the ISO le for your motherboard.
5-26 S UPER S ERVER 6028R-TR/TRT User's Manual SuperDoctor® 5 The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface in Windows and Linux operating systems.
Chapter 5: Advanced Serverboard Setup 5-27 Figure 5-7. Installing the Onboard Battery OR Please handle used batteries carefully . Do not damage the battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landll.
5-28 S UPER S ERVER 6028R-TR/TRT User's Manual Notes.
Chapter 6: Advanced Chassis Setup 6-1 Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform mainte - nance on the SC825TQ-R740LPB chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered.
6-2 S UPER S ERVER 6028R-TR/TRT User's Manual Figure 6-1. Front and Rear Chassis Views System Reset 6-2 Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system status indications.
Chapter 6: Advanced Chassis Setup 6-3 6-3 System Fans Three 8-cm hot-swap fans provide the cooling for the system. It is very important that the chassis top cover is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis and cool the components.
6-4 S UPER S ERVER 6028R-TR/TRT User's Manual Figure 6-2. Removing System Cooling Fans 6-4 Drive Bay Installation/Removal Accessing the Drive Bays Y ou do not need to access the inside of the chassis or remove power to replace or swap SA T A drives.
Chapter 6: Advanced Chassis Setup 6-5 SA T A Drive Installation These drives are mounted in carriers to simplify their installation and removal from the chassis. The carriers also help promote proper airow for the drives. For this reason, even empty carriers without hard drives installed must remain in the chassis.
6-6 S UPER S ERVER 6028R-TR/TRT User's Manual Hard Drive Backplane The hard drives plug into a backplane that provides power , drive ID and bus termi - nation. A RAID controller can be used with the backplane to provide data security . The operating system you use must have RAID support to enable the hot-swap capability of the hard drives.
Chapter 6: Advanced Chassis Setup 6-7 6-5 Power Supply The SuperServer 6028R-TR/TRT has a 740 watt redundant power supply consisting of two power modules. Each power supply module has an auto-switching capability , which enables it to automatically sense and operate at a 100V - 240V input voltage.
6-8 S UPER S ERVER 6028R-TR/TRT User's Manual Notes.
Chapter 7: BIOS 7-1 Chapter 7 BIOS 7-1 Introducti on This chapter describes the AMI BIOS setup utility for the X10DRi/X10DRi-T . The ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS setup utility screens.
7-2 S UPER S ERVER 6028R-TR/TRT User's Manual How to Start the Setup Utility Normally , the only visible Power-On Self-T est (POST) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS setup utility .
Chapter 7: BIOS 7-3 The following Main menu items will be displayed: System Date/System Time Use this option to change the system date and time. Highlight System Date or System Time using the arrow keys. Enter new values using the keyboard. Press the <T ab> key or the arrow keys to move between elds.
7-4 S UPER S ERVER 6028R-TR/TRT User's Manual 7-3 Advanced Setup Congurations Use the arrow keys to select Advanced setup and press <Enter> to access the submenu items: W arning : T ake Caution when changing the Advanced settings.
Chapter 7: BIOS 7-5 W ait For 'F1' If Error Select Enabled to force the sys tem to wa it unt il th e ' F 1' key is pres se d if an e rr or oc cu rs. T he o pti ons a re D isa ble d and Enabled . Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function.
7-6 S UPER S ERVER 6028R-TR/TRT User's Manual CPU Conguration North Bridge This feature allows the user to congure the settings for the Intel North Bridge.
Chapter 7: BIOS 7-7 The following items will be display: PCI-E Port Link Status PCI-E Port Link Max PCI-E Port Link Speed PCI-E Port L0s Exit Latency Use this feature to set the length of time required for the port specied by the user to complete the transition from L0s to L0.
7-8 S UPER S ERVER 6028R-TR/TRT User's Manual No PCIe Port Active ECO Use this feature to select a workaround setting to implement the engineering- change order (ECO) on the system when PCI ports are not active. The options are PCU Squelch exit ignore option and Reset the SQ FLOP by CSR option.
Chapter 7: BIOS 7-9 Coherency Support (Isoch) Select Enable for the Iscoh VT -d engine to pass through A TS to enhance system performance. The options are Enable and Disable .
7-10 S UPER S ERVER 6028R-TR/TRT User's Manual Memory Conguration Enforce POR Select Enable to enforce POR restrictions on DDR4 frequency and voltage pro - gramming. The options are Auto , Enforce POR, Disabled and Enforce Stretch Goals. Memory Frequency Use this feature to set the maximum memory frequency for onboard memory modules.
Chapter 7: BIOS 7-1 1 Rank Interleaving Use this item to select a rank memory interleaving method. The options are Auto , 1-W ay , 2-W ay , 4-W ay , and 8-Way . A7 Mode Select Enabled to support the A7 (Addressing) mode to improve memory per - formance.
7-12 S UPER S ERVER 6028R-TR/TRT User's Manual write back one cache line every 16K cycles, if there is no delay caused by internal processing. By using this method, roughly 64 GB of memory behind the IO hub will be scrubbed every day . The options are Enable and Disable.
Chapter 7: BIOS 7-13 XHCI Hand-Off This is a work-around solution for operating systems that do not support XHCI (Ex - tensible Host Controller Interface) hand-off. The XHCI ownership change should be claimed by the XHCI driver . The settings are Enabled and Disabled.
7-14 S UPER S ERVER 6028R-TR/TRT User's Manual SA T A Conguration When this submenu is selected, AMI BIOS automatically detects the presence of the SA T A devices that are supported by the.
Chapter 7: BIOS 7-15 Port 0 ~ Port 5 SA T A Device T ype Use this item to specify if the SA T A port specied by the user should be con - nected to a Solid State drive or a Hard Disk Drive.
7-16 S UPER S ERVER 6028R-TR/TRT User's Manual Port 0 ~ Port 5 Hot Plug Select Enabled to enable hot-plugging support for a port specied by the user , which will allow the user to replace a SA T A disk drive installed on this port without shutting down the system.
Chapter 7: BIOS 7-17 • Software Preserve Support sSA T A Port 0~ Port 3 Select Enabled to enable an sSA T A port specied by the user . The options are Disabled and Enabled.
7-18 S UPER S ERVER 6028R-TR/TRT User's Manual sSA T A RAID Option ROM/UEFI Driver Select EFI to load the EFI driver for system boot. Select Legacy to load a legacy driver for system boot.
Chapter 7: BIOS 7-19 • ME Firmware Status #2 • Current State • Error Code Altitude This feature indicates the altitude of the platform this machine is located above the sea level. The value is shown in meters. If the value is unknown, enter the number "80000000".
7-20 S UPER S ERVER 6028R-TR/TRT User's Manual Above 4G Decoding (A vailable if the system supports 64-bit PCI decoding) Select Enabled to decode a PCI device that supports 64-bit in the space above 4G Address. The options are Enabled and Disabled.
Chapter 7: BIOS 7-21 Onboard LAN Option ROM T ype Sel ec t Enab led t o ena ble O pti on RO M su ppo r t to boot the computer using a device installed on the slot specied by the user .
7-22 S UPER S ERVER 6028R-TR/TRT User's Manual Device Mode Use this feature to congure SUART clock source settings. The options are 24MHz/13 and 24MHz. Serial Port 2 Attribute Select SOL to use COM Port 2 as a Serial_Over_LAN (SOL) port for console redi - rection.
Chapter 7: BIOS 7-23 is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a parity bit to be sent along with the data bits. Select Space to add a Space as a parity bit to be sent with your data bits.
7-24 S UPER S ERVER 6028R-TR/TRT User's Manual SOL/COM2 Console Redirection Select Enabled to use the SOL port for Console Redirection. The options are Enabled and Disabled.
Chapter 7: BIOS 7-25 Flow Control Use this feature to set the ow control for Console Redirection to prevent data loss caused by buffer overow . Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start data-sending when the receiving buffer is empty .
7-26 S UPER S ERVER 6028R-TR/TRT User's Manual *If the item above set to Enabled, the following items will become available for user's conguration: Out-of-Band Management Port The feature selects a serial port in a client server to be used by the Windows Emergency Management Services (EMS) to communicate with a remote host server .
Chapter 7: BIOS 7-27 T rusted Computing (Availab le when a TPM device is installed and detected by the BIOS) Conguration Security Device Support If this feature and the TPM jumper on the motherboard are both set to Enabled, onboard security devices will be enabled for TPM support to enhance data integrity and network security .
7-28 S UPER S ERVER 6028R-TR/TRT User's Manual ACPI Settings WHEA Support Sel ec t Enab led t o supp or t th e Win dow s Har dwa re Er ro r Ar ch itec tu re ( W HE A) pl at - for m an d prov .
Chapter 7: BIOS 7-29 7-4 E vent Logs Use this feature to congure Event Log settings. Change SMBIOS Event Log Settings This feature allows the user to congure SMBIOS Event settings. Enabling/Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS (System Management BIOS) Event Logging during system boot.
7-30 S UPER S ERVER 6028R-TR/TRT User's Manual Memory Correctable Error Threshold Use this item to enter the threshold value for correctable memory errors.
Chapter 7: BIOS 7-31 7 -5 IPMI Use this feature to congure Intelligent Platform Management Interface (IPMI) settings. IPMI Firmware Revision This item indicates the IPMI rmware revision used in your system. IPMI Status This item indicates the status of the IPMI rmware installed in your system.
7-32 S UPER S ERVER 6028R-TR/TRT User's Manual When SEL is Full This feature allows the user to determine what the BIOS should do when the sys - tem event log is full. Select Erase Immediately to erase all events in the log when the system event log is full.
Chapter 7: BIOS 7-33 Gateway IP Address This item displays the Gateway IP address for this computer . This should be in decimal and in dotted quad form (i.e., 192.168.10.253). Router MAC Address This item displays the Router MAC address for this computer .
7-34 S UPER S ERVER 6028R-TR/TRT User's Manual 7-6 Security Settings Thi s men u all ows t he u ser to co n gur e the fol low ing s ec ur it y set t ing s fo r the syste m. Administrator Passw ord Use t his fe atur e to set t he ad min ist rato r pas swo rd wh ic h is re qui red b efo re ente r ing the B IO S setup u til it y.
Chapter 7: BIOS 7-35 7-7 Boot Settings Use th is feat ure to c on g ure Bo ot Set t ing s: Boot Mode Select Use this item to select the type of device to be used for system boot. The options are Legacy , UEFI, and Dual. The default setting is Dual.
7-36 S UPER S ERVER 6028R-TR/TRT User's Manual • Dual Boot Order #10 • Dual Boot Order #1 1 • Dual Boot Order #12 • Dual Boot Order #13 • Dual Boot Order #14 • Dual Boot Order #15 Add New Boot Option This feature allows the user to add a new boot option to system boot features.
Chapter 7: BIOS 7-37 7-8 Save & Exit Select the Save & Exit tab from the BIOS setup screen to congure the settings below . Discard Changes and Exit Select this option to quit the BIOS setup without making any permanent changes to the system conguration, and reboot the computer .
7-38 S UPER S ERVER 6028R-TR/TRT User's Manual Restore Defaults T o set this feature, select Restore Defaults from the Exit menu and press <Enter>. These are manufacture default settings designed for maximum system performance but not for maximum stability .
A-1 Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-T est) routines, which are performed at each system boot, errors may occur . Non-fatal errors are those which, in most cases, allow the system to continue to boot.
A-2 S UPER S ERVER 6028R-TR/TRT User's Manual Notes.
B-1 Appendix B: System Specications Appendix B System Specications Processors Sin gle o r dua l Intel ® E5-2600 Series (V3) Socket R3 processors in LGA 201 1 sockets (both CPUs must be of the same type) No te: A ll PC I - E s lot s w ill n ot b e en abl ed w h en us in g on ly a si ng le p ro c es so r.
B-2 S UPER S ERVER 6028R-TR/TRT User's Manual Chassis SC825TQ-R740LPB (2U rackmount) Dimensions: (WxHxD) 16.8 x 3.5 x 25.5 in. (427 x 89 x 648 mm) Weight 57 lbs. (25.9 kg.) System Cooling Three 8-cm system cooling fans System Input Requirements AC Input V oltage: 100 - 240V AC auto-range Rated Input Current: 9 - 3.
B-3 Appendix B: System Specications Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-1 1) Safety: CSA/EN/.
B-4 S UPER S ERVER 6028R-TR/TRT User's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Supermicro SuperServer 6028R-TR è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Supermicro SuperServer 6028R-TR - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Supermicro SuperServer 6028R-TR imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Supermicro SuperServer 6028R-TR ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Supermicro SuperServer 6028R-TR, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Supermicro SuperServer 6028R-TR.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Supermicro SuperServer 6028R-TR. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Supermicro SuperServer 6028R-TR insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.