Manuale d’uso / di manutenzione del prodotto Quickie V-121 del fabbricante Sunrise Medical
Vai alla pagina of 23
SUPPLIER: THIS MANUAL MUST BE GIVEN T O THE RIDER OF THIS WHEELCHAIR. RIDER: BEFORE USING THIS WHEELCHAIR READ THIS ENTIRE MANUAL AND SA VE FOR FUTURE REFERENCE.
2 3 930483 Rev . A 930483 Rev . A 11. T ABLE OF CONTENTS 1. INTRODUCTION .............................................................................. 2 11. T ABLE OF CONTENTS .................................................................. 3 111. Y OUR CHAIR AND ITS P AR TS .
4 5 930483 Rev . A 930483 Rev . A 111. Y OUR CHAIR AND ITS P ARTS QUICKIE V -121 1 2 3 7 4 5 6 10 15 11 13 12 14 8 9 1. Push Handle 2. Jo ystick 3. Integral Controller 4. Swing-Awa y Footrest 5. Heel Loop 6. Foot Plate 7. Cross Brace 8. Caster Fork 9.
1V . NO TICE—READ BEFORE USE A. CHOOSE THE RIGHT CHAIR & SAFETY OPTIONS Sunrise pro vides a choice of many power wheelchair styles, sizes and adjust- ments to meet the needs of the rider . Howe ver , final selection of a wheelchair rests solel y with you and y our health care prof essional.
8 9 930483 Rev . A 930483 Rev . A 2. Medium-Range Mobile T ransceiv ers: These include two-wa y radios used in police cars, fire trucks, ambulances and taxi cabs. The antenna is usually mounted on the outside of the vehicle. 3. Long-Range T ransceivers: These include commercial radio and TV br oadcast antenna towers and amateur (HAM) radios.
10 11 930483 Rev . A 930483 Rev . A V1. GENERAL W ARNINGS C. WEIGHT LIMIT 1. Nev er exceed a total weight of 250 pounds (113.6 kilograms) for rider plus items carried. 2. Nev er use this chair for weight training if the total weight (rider plus ad ditional weights) exceeds 250 pounds.
12 13 930483 Rev . A 930483 Rev . A VI. GENERAL W ARNINGS K. STREET USE In most states, power chairs ar e not legal for use on public roads. Be alert to the danger of motor vehicles on r oads or in parking lots. 1. At night, or when it is hard to see, use reflectiv e tape on your chair and clothing.
14 15 930483 Rev . A 930483 Rev . A VI. GENERAL W ARNINGS O . REA CHING OR LEANING Reaching or leaning affects the center of balance of y our chair . If done impr operly , a fall or tip-ov er is lik ely . When in doubt, ask for help or use a device to extend your r each.
16 17 930483 Rev . A 930483 Rev . A VI. GENERAL W ARNINGS Fig. 1 T . T O REDUCE THE RISK OF A F ALL, TIP-O VER OR LOSS OF CONTROL: 1. Never use y our chair on a slope unless you ar e sure you can do so without losing traction. 2. Alwa ys go as straight up and as straight down as y ou can.
18 19 930483 Rev . A 930483 Rev . A W . CURBS & SINGLE STEPS 1. Y our chair is not designed to drive up or do wn a curb or step more than two (2) inches high. Doing so ma y: • Result in a fall or tip-ov er . • Damage the frame , wheels, axles or other chair parts, or loosen fasteners.
20 21 930483 Rev . A 930483 Rev . A F . FOOTRESTS 1. At the lowest point, footr ests should be at least 21/2 inches off the ground. If set too LO W , they ma y “hang up” on obstacles y ou can expect to find in normal use. This may cause the chair to stop sud denly and tip forward.
22 23 930483 Rev . A 930483 Rev . A VII. W ARNINGS: COMPONENTS & OPTIONS M. SEA TING SYSTEMS 1. Use of a seating system not appro ved b y Sunrise may alter the center of balance of this chair . This may cause a fall or tip-ov er . 2. Ne ver change the seating system of y our chair unless you consult your supplier first.
24 25 930483 Rev . A 930483 Rev . A A. NOTES 1. W ork Surface F or Set-Up: Use a flat surface, such as a table, to assemble , adjust and check your chair .
26 27 930483 Rev . A 930483 Rev . A IX. SET UP , ADJUSTMENT & USE D .TO FIND & CORRECT A PROBLEM 1 First: Follow steps in this section to mak e sure set-up is cor rect. 2. Second: If step 1 does not work, consult your supplier f or help . 3. If Y ou Still Ha ve A Problem: contact Sunrise Medical Customer Ser vice at (800) 333-4000.
28 29 930483 Rev . A 930483 Rev . A IX. SET UP , ADJUSTMENT & USE b. Pull up on the armrest pad to the desir ed location. 5.T o Replace: a. Tilt armrest back and insert rear arm tube (3) into receiv er (4). b. Tilt armrest forwar d. This will engage pin to secure rear arm tube.
31 930483 Rev . A X. OPERA TING GUIDE 2. T o Program Y our Chair : a. T urn off power to the chair . b. Insert QTR ONIX Programmer plug (A) into the Programmer/Charger sock et (B) on the front of the jo ystick. c. T urn on pow er to the chair ; program as needed.
33 930483 Rev . A 32 930483 Rev . A Note: If your speed becomes har d to manage , release the J oystick and the chair will come to a complete stop. • When you r elease the joystick it will return to neutral; the chair will slow to a stop and the motor locks will reengage.
35 930483 Rev . A 34 930483 Rev . A • Ne ver place a battery on top of the charger . • Ne ver expose charger to rain or sno w . • Ne ver unplug charger b y pulling on the electrical cord. This will damage the cord. • Nev er open a charger or attempt to repair it yourself.
37 930483 Rev . A 36 930483 Rev . A XI. BA TTERIES 3. Never use an e xtension cord. Use of an impr oper cord could damage the charger , or cause a fire or electrical shock. 4. Do not use charger if it has been dropped or damag ed. 5. A batter y emits explosive h ydro gen gas during charging.
39 930483 Rev . A 38 930483 Rev . A D . BA TTER Y MAINTENANCE 1. T o pre vent an acid spill, alwa ys keep batteries upright. 2. Never smok e or hold an open flame near batteries. 3. Always w ear rubber glov es and safety glasses when you handle batteries.
41 930483 Rev . A 40 930483 Rev . A XII. MAINTENANCE 2. 12" Drive Wheels: a. Elevate and securel y suppor t chair so that wheel is off the ground. Release all air from tir e . b. Remov e plastic dome plug. c. Remove lock n ut and tab washer . d. Remov e wheel.
43 930483 Rev . A 42 930483 Rev . A XIV . SUNRISE LIMITED W ARRANTY 1. FOR 5 YEARS W e warrant the main frame of this wheelchair against defects in materials and workmanship f or 5 years after the first consumer pur chase .
Sunrise Medical 7477 East Dry Creek Parkway • Longmont, Colorado • 80503 USA (800) 333-4000 In Canada (800) 263-3390 Manufactured under one or mor e of the following patents: U.S. Patent # 5,062,677; 5,149,173; 5,211,446; 5,352,023; 5,407,248; plus other foreign patents.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sunrise Medical Quickie V-121 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sunrise Medical Quickie V-121 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sunrise Medical Quickie V-121 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sunrise Medical Quickie V-121 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sunrise Medical Quickie V-121, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sunrise Medical Quickie V-121.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sunrise Medical Quickie V-121. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sunrise Medical Quickie V-121 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.