Manuale d’uso / di manutenzione del prodotto 2.0 del fabbricante Sun Microsystems
Vai alla pagina of 64
Sun Microsystems, Inc. www .sun.com Submit comments about this document at: http://www.sun.com/hwdocs/feedback Sun StorageT ek ™ 4 Gb FC NEM 20-P or t Host Bus Adapter User’ s Guide F or HBA Model SG-XPCIE20FC-NEM-Z P ar t No .
Please Recycle Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc.
iii Contents Preface vii 1. Network Express Module Overview 1 NEM Features and Specifications 1 ID Chip Feature 3 Operating System Requirements 4 System Interoperability 4 Host Platform Support 5 Storage System Support 5 Fibre Channel Switch Support 6 2.
iv Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 Using the ILOM W eb Interface 16 Using the ILOM CLI 16 ▼ T o V erify NEM Status 16 Replacing a NEM 18 ▼ T o Install the ID Chip Patch 18 ▼ T o Remove a NEM 18 ▼ T o Replace the ID Chip 19 3.
Contents v Declaration of Conformity 33 Safety Agency Compliance Statement 35 Regulatory Compliance Statements 47 Index 51.
vi Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007.
vii Pr eface This guide describes how to install and remove the Sun StorageT ek™ 4 Gb Fibre Channel (FC) Network Express Module (NEM) Host Bus Adapter (HBA), 20-port pass-through RoHS 5 compliant module.
viii Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 Using UNIX Commands This document might not contain information about basic UNIX ® commands and procedur es such as shutting down the system, booting the system, and configuring devices.
Preface ix T ypographic Conventions Related Documentation The documents listed are available at: http://www.sun.com/documentation/ T ypeface * * The settings on your browser might differ from these settings. Meaning Examples AaBbCc123 The names of commands, files, and directories; on-scr een computer output Edit your .
x Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 Documentation, Support, and T raining Thir d-Party W eb Sites Sun is not responsible for the availability of third-party web sites mentioned in this document.
Preface xi Service Contact Information If you need help installing or using this product, call 1-800-USA-4SUN, or go to: http://www.sun.com/service/contacting/.
xii Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007.
1 CHAPTER 1 Network Expr ess Module Overview This chapter provides a basic overview of the Sun StorageT ek™ 4 Gb Fibre Channel (FC) Network Express Module (NEM) Host Bus Adapter (HBA). This chapter also describes the various operating systems, host platforms, storage, and infrastructure configurations that support the NEM.
2 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 T wenty SFP fiber -optic transceivers are included with each NEM. Y ou can order additional NEMs and SFP transceivers from Sun Microsystems using the following part numbers: See T ABLE 1-1 for a list of the NEM’s featur es.
Chapter 1 Network Express Module Overview 3 ID Chip Featur e When you replace a NEM, each of the 10 HBAs and 20 FC ports on the NEM will be assigned new port and node worldwide names (WWNs).T o retain the existing WWNs you can remove the ID chip fr om the NEM that failed and install it on the replacement NEM.
4 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 See “Replacing a NEM” on page 18 for more information. Operating System Requir ements The NEM requir es the operating system (OS) levels listed in T ABLE 1-2 .
Chapter 1 Network Express Module Overview 5 Host Platform Support The NEM is supported by the platforms and operating systems (OSs) listed in T ABLE 1-3 . Y ou can install the NEM in an available NEM slot of the Sun Blade 8000 Chassis or Sun Blade 8000 P chassis.
6 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 Fibr e Channel Switch Support The NEM is supported with the following FC switches: ■ 2 Gb QLogic SANbox 5200 switch .
7 CHAPTER 2 Har dware Installation and Removal This chapter describes the tasks requir ed to install and remove the NEM when the Sun Blade 8000 Modular System is in a power ed-on state.
8 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 Observing ESD and Handling Pr ecautions Caution – Damage to the NEM can occur as the result of careless handling or electrostatic dischar ge (ESD). Always handle the NEM with care to avoid damage to electrostatic sensitive components.
Chapter 2 Hardware Installation and Remov al 9 ▼ T o Install the NEM 1. Attach an antistatic strap (refer to “Observing ESD and Handling Precautions” on page 8 ). 2. Refer to your system installation or service manual to determine an appropriate slot in which to install the NEM.
10 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 6. Align the NEM with the chassis guidance system and slide the NEM into its slot (see FIGURE 2-2 ). Ensure that the NEM engages with the system chassis guidance system.
Chapter 2 Hardware Installation and Remov al 11 9. V erify that the NEM is working properly . See “T o V erify NEM Status” on page 16 . ▼ T o Connect the Optical Cables Note – The NEM does not.
12 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 FIGURE 2-3 Connecting the Optical Cables 2. Connect the other end of each cable to a FC device. After the optical cables are connected to the NEM, pr oceed to “Configuring the NEM For Hot-Plug Operation” on page 14 .
Chapter 2 Hardware Installation and Remov al 13 FIGURE 2-4 Port Level LEDs T ABLE 2-2 summarizes port LED indicator combinations. T ABLE 2-2 Port LED Indicator Status Definitions Green LED Y ellow LED.
14 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 Conf iguring the NEM For Hot-Plug Operation T o insert a NEM into the chassis while the system is running, you need to: 1.
Chapter 2 Hardware Installation and Remov al 15 4. V erify that the selected NEM has returned the expected feedback. See “T o V erify NEM Status” on page 16 . Using the ILOM Command-Line Interface 1. Log in to the ILOM CLI of the active Chassis Monitoring Module.
16 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 Y ou can use the ILOM web interface or ILOM CLI to verify Using the ILOM W eb Interface 1. Log in to the ILOM web interface using the IP address of the active Chassis Monitoring Module.
Chapter 2 Hardware Installation and Remov al 17 ■ Green OK LED goes to Standby . 2. Activate the NEM by pressing the Attention button, and the green OK LED goes to Slow blink. ■ When all links to active blades have been made, the green OK LED goes to Solid On.
18 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 The Locator button, when pressed momentarily , flashes a white light to assist in locating the module. Y ou can also activate the Locator LED remotely by executing a command on the CMM.
Chapter 2 Hardware Installation and Remov al 19 3. When the blue Ready-to-Remove LED is lit on the NEM, physically remove the NEM. a. Remove all cables from the NEM. b. Press the latch on both ejector levers inward at the same time. c. Swing out the ejector levers to their fully open position.
20 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 4. Install the ID chip onto the new board (see FIGURE 2-7 ). a. Position the notched side of the ID chip to the left. b. Place the ID chip directly over the connector .
21 CHAPTER 3 HBA Softwar e Installation After you have completed the hardwar e installation, follow the instructions listed in this chapter for your operating system to install the HBA driver and any other utilities requir ed for your installation.
22 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 ■ Self-test ■ Loopback tests ■ External ■ Internal, single-bit ■ Internal, 10-bit ■ Mailbox Driver Softwa.
Chapter 3 HBA Software Installation 23 Note – If you are running on a 2.6.5-7.244 kernel, you must install the Emulex 8.0.16.27 driver manually instead of updating using Y aST .
24 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 Driver Softwar e for W indows 2003 OS The HBA driver for W indows 2003 OS is available for download at the Emulex support site for Sun Microsystems. http://www.emulex.com/sun/support/nem-e11000.
Chapter 3 HBA Software Installation 25 ■ Manage out-of-band HBAs ■ Manage local and in-band remote HBAs See the Linux or W indows OS Emulex user manual for more information about using the HBAnywhere and lputil utilities.
26 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007.
27 CHAPTER 4 Release Notes This chapter contains the latest supplementary information for the preceding chapters in this guide. It contains the following topics: ■ Using the NEM W ith Sun StorEdge 3.
28 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007 Solaris OS-Specif ic Issues The following known issues are r elated to installing, configuring, or operating the NEM with the Solaris 10 OS.
Chapter 4 Release Notes 29.
30 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007.
31 APPENDIX A Declaration of Conformity , Regulatory Compliance, and Safety Statements This appendix contains the following information that applies to the Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus.
32 Sun StorageTek 4 Gb FC NEM Host Bus Adapter User’s Guide • May 2007.
33 << Declaration of Conformity Compliance Model Number: 375-3385-XX Product Family Name: Sun StorageT ek 4 Gb FC NEM HBA EMC USA - FCC Class A This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This equipment may not cause harmful interference.
34 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • May 2007.
35 Safety Agency Compliance Statement Read this section before beginning any procedure. The following text provides safety precautions to follow when installing a Sun Microsystems product.
36 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • May 2007 Power Cord Connection Caution – Sun products ar e designed to work with power systems having a grounded neutral (grounded r eturn for DC-power ed products). T o reduce the risk of electric shock, do not plug Sun products into any other type of power system.
Safety Agency Compliance Statement 37 Rack System Warning The following warnings apply to Racks and Rack Mounted systems. Caution – For safety , equipment should always be loaded from the bottom up. That is, install the equipment that will be mounted in the lowest part of the rack first, then the next higher systems, etc.
38 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • May 2007 Symboles Vous trouverez ci-dessous la signification des différents symboles utilisés: Attention – Vous risquez d'endommager le matériel ou de vous blesser .
Safety Agency Compliance Statement 39 Attention – T ous les cordons d'alimentation ne présentent pas les mêmes caractéristiques électriques. Les cordons d'alimentation à usage domestique ne sont pas protégés contr e les surtensions et ne sont pas conçus pour être utilisés avec des ordinateurs.
40 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • May 2007 Attention – Afin d'éviter que le rack ne penche pendant l'installation du matériel, tirez la barre anti-basculement du rack.
Safety Agency Compliance Statement 41 Je nach Netzschaltertyp an Ihrem Gerät kann eines der folgenden Symbole verwendet werden: Ein – V ersor gt das System mit W echselstrom. Aus– Unterbricht die W echselstromzufuhr zum Gerät. Wartezustand – Der Ein-/Standby-Netz- schalter befindet sich in der Standby-Position.
42 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • May 2007 Die folgende Warnung gilt nur für Geräte mit Standby- Netzschalter: Achtung – Beim Netzschalter dieses Geräts handelt es sich nur um einen Ein/Standby- Schalter .
Safety Agency Compliance Statement 43 Hinweis zur Laser-Konformität Sun-Produkte, die die Laser-Technologie verwenden, entsprechen den Laser-Anforderungen der Klasse 1.
44 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • May 2007 Nivel de ruido Emisiones acústicas declaradas de acuerdo con la norma ISO 9296 (decibelios A), en funcionamiento y.
Safety Agency Compliance Statement 45 Cubierta de la unidad del sistema Debe extraer la cubierta de la unidad del sistema informático Sun para instalar tarjetas, memoria o dispositivos de almacenamiento internos. Vuelva a colocar la cubierta antes de encender el sistema informático.
46 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • May 2007 Danmark Advarsel! – Litiumbatteri — Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
47 Regulatory Compliance Statements Y our Sun product is marked to indicate its compliance class: • Federal Communications Commission (FCC) — USA • Industry Canada Equipment Standard for Digital.
48 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • May 2007 BSMI Class A Notice The following statement is applicable to products shipped to T aiwan and marked as Class A on the pr oduct compliance label.
Regulatory Compliance Statements 49 CCC Class A Notice The following statement is applicable to products shipped to China and marked with “Class A” on the pr oduct’s compliance label.
50 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • May 2007.
51 Index A Attention button, 17 B BIOS POST, 28 C cable length, maximum, 2 channel LEDs, 13 chassis monitoring module (CMM) firmware, 5 using ILOM, 14 compliance statements regulatory, 47 safety agen.
52 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • May 2007 links connected to blades status, 17 Linux driver , known issues, 2 8 supported versions, 4 Locator LED and button,.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sun Microsystems 2.0 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sun Microsystems 2.0 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sun Microsystems 2.0 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sun Microsystems 2.0 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sun Microsystems 2.0, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sun Microsystems 2.0.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sun Microsystems 2.0. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sun Microsystems 2.0 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.