© 2012 Stanley Black & Decker , Inc. New Britain, CT 06053 U.S.A. 72962 7/2014 V er . 3 BR50 HYDRAULIC BREAKER USER MANUAL Safety , Operation and Maintenance.
2 ► BR50 User Manual DECLARATION OF CONF ORM ITY ÜBEREINSTIMM UNGS - ERKLARUNG DECLARATION DE CONF ORMITE CEE DECLARACION DE CONFO RMIDAD DICHIARAZIONE DI CONFO RMITA Hydraulic Tools _______ ______.
BR50 User Manual ◄ 3 SERVICING: This manual contains safety , operation, and routine maintenance instructions. Stanley Hydraulic T ools recommends that servicing of hydraulic tools, other than routine maintenance, must be performed by an authorized and certied dealer .
4 ► BR50 User Manual Always observe safety symbols. They are included for your safety and for the protection of the tool. LOCAL SAFETY REGULA TIONS Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and mainte- nance personnel.
BR50 User Manual ◄ 5 T ool operators and maintenance personnel must always comply with the safety precautions given in this manual and on the stickers and tags attached to the tool and hose. These safety precautions are given for your safety . Re- view them carefully before operating the tool and before performing general maintenance or repairs.
6 ► BR50 User Manual • W arning: Hydraulic uid under pressure could cause skin injection injury . If you are injured by hydraulic uid, get medical attention immediately . • Keep all body parts away from the working tool. • When handling material or the tool bit, wear your (PPE) Personal Protection Equipment.
BR50 User Manual ◄ 7 SAFETY T AG P/N 15875 (Shown smaller then actual size) DANGER DANGER READ OPERA TION MANUAL AND SAFETY INSTRUCTIONS FOR THIS TOOL BEFORE USING IT . USE ONL Y P ARTS AND REP AIR PROCEDURES APPROVED BY ST ANLEY AND DESCRIBED IN THE OPERA TION MANUAL.
8 ► BR50 User Manual The rated working pressure of the hydraulic hose must be equal to or higher than the relief valve setting on the hy- draulic system. There are three types of hydraulic hose that meet this requirement and are authorized for use with Stanley Hydraulic T ools.
BR50 User Manual ◄ 9 Oil Flow Hose Lengths Inside Diameter USE ( Press/Return) Min. Working Pressure GPM LPM FEET METERS INCH MM PSI BAR Certied Non-Conductive Hose - Fiber Braid - for Utility Bu.
10 ► BR50 User Manual Flow Range Nominal Operating Pressure (at the power supply outlet) System relief valve setting (at the power supply outlet) Maximum back pressure (at tool end of the return hose) Measured at a max. uid viscosity of: (at min.
BR50 User Manual ◄ 1 1 NOTE: Partially depressing the trigger allows the tool to run at slow speed. Slow-speed operation permits easier starting of the tool bit into the work surface. 5. T o start, break an opening (hole) in the center of the surface.
12 ► BR50 User Manual • Make sure all couplers are wiped clean before con- nection. • The hydraulic circuit control valve must be in the OFF position when coupling or uncoupling hydrau- lic tools. Failure to do so may result in damage to the quick couplers and cause overheating of the hy- draulic system.
BR50 User Manual ◄ 13 PROBLEM CAUSE REMEDY T ool does not run. Power unit not functioning. Check power source for proper ow and pressure (7–9 gpm/ 26–34 lpm, 2000 psi/ 140 bar) or 5–6 gpm /18–22 lpm at 1500–2000 psi /105–140 bar . Couplers or hoses blocked.
14 ► BR50 User Manual ACCUMULA TOR TESTING PROCEDURE T o check or charge the accumulator the following equip - ment is required: • 31254 Charge Kit: which includes the following. – Accumulator T ester (Part Number 02835). – Charging Assembly (P/N 15304: includes a liq- uid lled gauge with snub valve, hose and t - tings).
BR50 User Manual ◄ 15 Pressure Range................................................................................................................ 1500-2000 psi/105-140 bar Maximum Back Pressure.....................................................
16 ► BR50 User Manual TEST EQUIPMENT Accumulator T ester ............................................................................................................................................ 02835 Flow and Pressure T ester ...................
BR50 User Manual ◄ 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 3 15 11 12 32 33 34 35 36 37 38 39 37 38 40 41 42 43 44 46 45 PICTURED IS A BR50120 FOR BREAKER FOOT P ARTS THA T PERT AIN TO YOUR MODEL SEE P AGES 21 thru 23.
18 ► BR50 User Manual ITEM P/N QTY DESCRIPTION 1 01652 2 HOSE WHIP 12" 2 02494 2 HANDLE GRIP 3 02900 2 ROLL PIN 4 03972 1 COUPLER,3/8FEM. 3/8NPT 5 03973 1 COUPLER,3/8MALE 3/8NPT 6 04058 1 SPRIN.
BR50 User Manual ◄ 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 3 51 52 53 54 55 56 57 58 59 60 61 62 63 64 56 57 65 8 9 PICTURED IS A BR5017801 FOR BREAKER FOOT P ARTS THA T PERT AIN TO YOUR MODEL SEE P AGES 21 thru 23.
20 ► BR50 User Manual ITEM P/N QTY DESCRIPTION 1 01652 2 HOSE WHIP 12" 2 02494 2 HANDLE GRIP 3 02900 2 ROLL PIN 4 03972 1 COUPLER,3/8FEM. 3/8NPT FL.
BR50 User Manual ◄ 21 INSTALL WITH A LIGHT COATING OF LOCTITE #609 ON I.D. OF FOOT BORE INSTALL WITH LOCTITE #609 2 1 3 1 4 1 6 1 14 1 5 1 11 1 12 1 10 1 13 1 1 1 7 1 8 1 9 1 9 1 1 1 ITEM P/N QTY DE.
22 ► BR50 User Manual INSTALL WITH A LIGHT COATING OF LOCTITE #609 ON I.D. OF FOOT BORE INSTALL WITH LOCTITE #609 2 1 3 1 4 1 6 1 14 1 5 1 11 1 12 1 10 1 13 1 1 1 7 1 8 1 9 1 9 1 1 1 ITEM P/N QTY DE.
BR50 User Manual ◄ 23 INSTALL WITH LOCTITE #609 INSTALL WITH A LIGHT COATING OF LOCTITE #609 ON I.D. OF FOOT BORE. ALIGN HEX AS SHOWN 2 1 3 1 4 1 17 1 5 1 12 1 9 1 16 1 10 1 13 1 11 1 15 1 14 1 1 1 .
Stanley Hydraulic T ools 3810 SE Naef Road Milwaukie, Oregon 97267-5698 USA (503) 659-5660 / Fax (503) 652-1780 www .stanleyhydraulics.com.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Stanley Black & Decker BR50 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Stanley Black & Decker BR50 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Stanley Black & Decker BR50 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Stanley Black & Decker BR50 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Stanley Black & Decker BR50, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Stanley Black & Decker BR50.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Stanley Black & Decker BR50. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Stanley Black & Decker BR50 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.