/ Mar le y Class 60 0 Cooling T ower /.
2.
3 / Flexibility of Design / Class 600 cooling towers are a dir ect descendent of the Doubleflow ® crossflow tower that was designed and patented by Marley in 1938.
4 Fans Marley designed and manufactured fans ar e used on all Marley crossflow towers. The fan selection and fan speed for a given tower are based on tower cell size, system losses, and horsepower requir ements. Depending on fan size, blade material is FRP (fiber reinfor ced polyester), GRE (glass reinfor ced epoxy), or cast aluminum alloy .
5 Geareducer The Marley Geareducer ® has become the standar d by which all other cooling tower fan speed reducers are judged. Numer ous reduction ratios ar e available so that horsepower is applied at optimum fan speed. The specific Geareducer selection is based on fan speed and horsepower requir ements up to 300 hp per fan.
6 Class 600 splash fill bars are available in the following materials: • PVCin“Omega”,“Mega”or“Alpha” configurations. • Injection-moldedpolypropylene“Ladder” configurations. • Roughsawn,preservative-tr eatedwood “G” configurations.
7 Piping Although side inlet piping is provided as standar d, Class 600 towers are adaptable to end inlet piping. This is an economical method requiring only one riser for each series of hot water basins, regar dless of the number of fan cells. Cast iron, steel, and r einforced plastic pipe ar e all available.
8 / Dr ift Eliminat ors / Marley towers utilize Marley XCEL ® plus drift eliminators, a cellular , labyrinthine design which improves drift elimination by several orders of magnitude over that achievable by blade-type eliminators. Significantly lower pressur e losses also reduce fan horsepower requir ements.
9 The diagonals brace the structure and carry loads to heavy-duty , hot dip glavanized anchor castings. The anchor castings transmit wind and/or earthquake loads from the structur e directly into the foundation. For standard wind load conditions, anchor bolts ar e requir ed only at the perimeter .
10 / Casing / The endwalls of Class 600 towers are cased fr om the fan deck level to below the top of the basin curb with 8 oz/sq ft corrugated FRP sheets. FRP is waterproof and corrosion pr oof, is immune to biological deterioration, and requir es no maintenance.
11 Endwall Derrick The endwall derrick is a permanently installed tripod device of galvanized structural steel. In service, removable structural aluminum tracks are positioned acr oss the platform opening. Equipment to be handled is placed on a 4-wheel dolly—part of the equipment handling package—rolled onto the track and elevated slightly .
SPX Cooling T echnologies is dedicated to satisfying the needs of our customers—needs which begin far in advance of the actual purchase of a new Marley cooling tower , and vary over the operating lifetime of the project.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il SPX Cooling Technologies 600 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del SPX Cooling Technologies 600 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso SPX Cooling Technologies 600 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul SPX Cooling Technologies 600 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il SPX Cooling Technologies 600, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del SPX Cooling Technologies 600.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il SPX Cooling Technologies 600. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo SPX Cooling Technologies 600 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.