http: //www.del ta.com .tw/i ndustr ialau tomation / DEL T A T emperature Controller DTB Series User Manual.
1 B Series Temperature Controller User Manual 1 Precaution DANGER! Caution! E lectric Shock! 1. Do not touch th e AC terminals w hile the power is sup plied to the controller to prevent an electric s hock. 2. Make sure pow er is disconnected while checking th e unit insi de.
2 4 Specifica tions 5 T emperature Sensor T ype and T emperature Range Input T emperature Sensor T ype Register V alue LED Display T emperat ure Range 0~50mV Analog Input 17 -999 ~ 9999 4~20mA Analog .
3 6 Operation There are three modes of operation: operation, regulation and in itial setting. When power is applied, controller gets into the operation mode. Press the key to switch to regulation mode. If the key is pressed for more than 3 seconds, c ontroller will switch to t he initial setting mode.
4 T ime setting for valve from full close to full open. (Displa y when valve cont r ol is ON) Pr ess D ispl ay and ad jus t out put va lu e of 1st o utp ut gr oup (Di s pla y in PID con tr ol mode and man ual RU N m o d e) Press ASCII, RTU com mun ication format select io n Press Pr e s s V alv e Dea d B and setti ng.
5 7 Dual Loop Output Control (Heating / Cooling Contr ol) OF F PV Set p oint ON He atin g De ad ban d He ati n g h yst eresi s Fi gure 1. O utp ut d uri ng dua l l oo p out put con t ro l oper ation o.
6 8 Alarm Output s There are up to three groups of alarm outputs and each group allows thirteen alarm types in the initial setting mode. The alarm output is activated whenever the process temperature value (PV) is getting higher or lo wer than the set point of alarm limit.
7 9 Current T ransformer (CT) Function The Current T ransformer ( CT) function is used with the alarm out put. When using a current transforme r (CT) with the controller , change the corresponding alarm output mode to mode 13 (alarm output set value is 13), then turn to operation mode and set the current lowe r-limit and current upper-limit.
8 13 RS-485 Communication 1. Supporting transmission speed: 2400, 4800, 9600, 19200, 38400bps 2. Non-supported formats: 7, N, 1 or 8, O, 2 or 8, E, 2 3. Communication protocol: Modbus (ASCII or RTU) 4. Function code: 03H to read the contents of register (Max.
9 1030H S tart pattern number 0 ~ 7 1040H~ 1047H Actual step number setting inside the correspond pattern 0 ~ 7 = N, indicate that this pattern is executed from step 0 to step N 1050H~ 1057H Cycle num.
10 14 Panel Cutout and T erminals Identification Panel Cutout ( dimensions are in millimeter and inch) T ermi nals Identification DTB4824 65 .0 m in. (2. 56) 4 0 . 0 m i n . ( 1 . 5 8 ) 44 .8 (1. 76) 2 2 . 0 ( 0 .8 7 ) +0.6 -0 +0.02 -0 + 0 . 6 - 0 + 0 .
11 15 External Dimensions Dim ensions are in millimeter (inch) DTB4824 DTB4848 48.0 mm (1.89 in) 2 4 . 0 m m ( 0 . 9 4 i n ) 3.4 mm (0.13 in) 99.8 mm (3.93 in) 2 1 . 8 5 m m ( 0 . 8 6 i n ) 44.75 mm (1.76 in) 2 2 . 0 m m ( 0 . 8 7 i n ) 44.8 mm (1.
12 16 Mounting Mounting Method Mounting Bracket Installation CT Wiring Method (if C T function is selected) S tep 1 : Insert t he controller through the panel cutout.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il B&B Electronics DTB Series è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del B&B Electronics DTB Series - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso B&B Electronics DTB Series imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul B&B Electronics DTB Series ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il B&B Electronics DTB Series, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del B&B Electronics DTB Series.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il B&B Electronics DTB Series. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo B&B Electronics DTB Series insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.