OPERA TION MANUAL SMC Corporation SI unit EX120-SDN1 Doc.No. EX## -OME0015 EX121-SDN1 EX122-SDN1 EX124D/U-SDN1.
Contents 1.Safety instructions ------------------------------------------------------ P3 2.S pecifications 2-1.General specifications ------------------------------------------------------ P4 2-2.Electrical and network specifications ------------------------------------------------------ P4 2-3.
SMC CORPORA TION Doc.No.EX ## -OME0015 1.Safety instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by label of "CAUTION" , "WARNING".
- 4 - 2-1. General specifications Item S pecifica tions Model EX120 -SDN1 EX121 -SDN1 EX122 -SDN1 EX124D -SDN1 EX124U -SDN1 Operatin g ambient temp. 0 to +55(with 8 po ints o f valve O N) 0 to +50 ℃ (with 16 p oints o f valv e ON) Operating a m bient humidity 35 to 85%RH(No dew cond ensation) S torage ambient temp.
- 5 - 3. Wiring and Setting 2-3. Applicab le solenoid v alve series SI unit V alv e series EX120 VQ1000, VQ2000 EX121 VQ1000, VQ2000, SX 3000, SX5 000 EX122 SY3000, SY5000 EX124U/ D VQ2000, VQ4000, VQ.
- 6 - Cable specification CAUTION For Multi drop connection, prepare plug connector for T branch separately . (Example, TMSTBP 2.5...- STF -5.08 made by Phoenix Contact Corp.) Use DeviceNet special cable for communication cable. Be sure to connect DeviceNet special terminal resistor with both ends of trunk.
Wiring of cable for solenoid valve power supply and communication Communication connector for DeviceNet T erminal Wire color Connected to V - Black (-) side of power supply cable CANL Blue Low side of.
3-2. Addr ess setting Before setting of address by DIP switch, turn power supply for communicat ion cable in SI unit “OFF ”. Setting (binary) of following items is available by DIP switch installed to cover . 1) Node address (00 to 63) 2) Communication speed (125k bps, 250 kbps, 500kbps) - 8 - SMC CORPORA TION Doc.
4.LED indicator and Physical dimensions - 9 - Indication Contents P W R Green Lights up when power for DeviceNet line is supplied. Lights off SI unit isn’t on line or power supply for communication line isn’t tur ned on .
- 10 - SI unit (EX122-SDN1) SI unit (EX121-SDN1) SMC CORPORA TION Doc.No.EX ## -OME0015 1 1 1 1 0 0 2 2 3 3 4 4 5 5 6 6 7 7 8 8 0 0 1 1 2 2 4 4 8 8 16 16 32 32 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 1 1 0 0 .
SI unit (EX124D-SDN1) SI unit (EX124U-SDN1) - 1 1 - SMC CORPORA TION Doc.No.EX ## -OME0015 4-G(PF)1/2 19 19.8 11 4 5.5 67 (72.5) 53.8 1 1.6.
5.EDS (Electronic Data Sheet) File SMC CORPORA TION Doc.No.EX ## -OME0015 The EDS File is a file which described ID information on SI unit and important information in the operation. The DeviceNet controller or scanner automatically recognizes the SI unit by referring to the EDS File.
6. T rouble Shooting - 13 - MOD/NE T L ED Cause & Countermeasure Light s off PWR L ED lig hts of f <Counte rmeasure> Confir m that power for SI unit circuit is sup plied. Confirm correct wi ring. If above cou ntermeasures do not improve st atus, p lease excha nge SI unit .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il SMC Networks EX122-SDN1 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del SMC Networks EX122-SDN1 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso SMC Networks EX122-SDN1 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul SMC Networks EX122-SDN1 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il SMC Networks EX122-SDN1, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del SMC Networks EX122-SDN1.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il SMC Networks EX122-SDN1. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo SMC Networks EX122-SDN1 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.