Manuale d’uso / di manutenzione del prodotto AM-002/ML-001 del fabbricante SkyLink
Vai alla pagina of 28
P/N. 101A379 OCT, 2005 PATENTED ©2005 SKYLINK GROUP AAA+ Control Panel www.skylinkhome.com CUSTOMER SERVICE 17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Tel : (905) 456-8883 Fax : (905) 456-7819 Email : support@skylinkhome.
AAA+ Control Panel USER'S INSTRUCTIONS English.
Declaration of Conformity Application of Council Directive(s) : Radio Equipment and Telecommunication Terminal Equipment Directive (1999/5/EC) - R&TTE Standard(s) to which Conformity is Declared: EMC: EN 55022:1998+A1: 2000, EN 610000-3-2: 2000, EN 61000-3.
– 2 – IC Statement ‘’This product meets the applicable Industry Canada technical specifications.” Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications com- pany.
– 3 – CONTENT Introduction..........................................................................................................................4 Overview.........................................................................................
– 4 – INTRODUCTION Overview Congratulations on your purchase of a Skylink Home Smart Center. This is a security control panel which not only functions as a security system, but also monitors your premises by giving you alert notification when the system is not armed.
INTRODUCTION – 5 – • One telephone cord • Rechargeable battery of the Control Panel: North American version European Version • Screws Installation of the Control Panel involves the following procedures: 1. Install Control Panel 2. Program Passwords 3.
INTRODUCTION ] 14 15 1. Zone LEDs 2. Numeric Keypad 3. Arm button 4. Status button 5. Mute button 6. Panic button 7. Power LED 8. Arm LED 9. Program LED 10. System Low Battery LED 11. Built-in Siren and Speaker 12. Programming button 13. Buzzer Mode Selector 14.
– 7 – Door/Window Sensor (WD-101) - Magnetic Contact Sensor - For all doors or windows - Batteries included Repeater (RP-434) - Extend the operation range between 2 wireless devices, such as any s.
– 8 – After mounting the door sensor, it - Please ensure the magnet is aligned with doesn’t work anymore. the red marking on the transmitter. - If you are mounting the sensor on to a metal door or window, a spacer may be required to avoid magnetic interference caused by the metal door / window.
Enter master 3 beeps for valid password to password. 1 long programming mode beep for invalid password. [1] - Master password [2] - Secondary password [3] - Duress password Select any 4-digit pass- word, each digit can be from 0 to 9 Enter the new password 3 beeps if new pass- again for confirmation word is accepted.
Phone Number Programming You can progra m up to 6 Emergency Phone Num bers. When the system is in panic, the control panel will call these phone numbers and announce its status.
Note: - It’s not recommended to program 911, fire station or any emergency services phone numbers into any of the phone memories without their approvals. - Ensure to program a valid phone number and write down the programmed phone number on the System Setting Information provide on the back of this user's instructions.
– 12 – HOME AUTOMATION Part 2 Erase communication from Control Panel to Control Module ZONE LED DESCRIPTION Off Zone is not occupied by any control module Flashes twice That means a remote has occupied that zone. THIS IS NOT A CONTROL MODULE, THEREFORE, SHOULD NOT BE ERASED.
– 13 – HOME AUTOMATION Erase Control Modules To erase a control module from the control panel, it is similar to learning a control module, which involves 2 parts.
– 14 – Part 2 Learn signal from Control Panel to Control Module HOME AUTOMATION Control Module [1] is represented by zone LED 1 CONTROL MODULE LOCA TION 1 6 2 7 3 8 4 9 5 0 TRANSMIT BUTTON [X] 1 2 Enter Programming mode LED on the Control Module will flash indicating it is in learn mode.
OPERATION Note: - Each zone can program up to 2 sensors. There are 5 zones, so up to 10 sensors can be programmed to the control panel. Please refer to page 34, "Sensor Location Selection Guide" for detail information.
T h e Control Panel can be used to co ntrol lights and home ap plicance s with a Control M odule, (Control Module is sold separately). Garage door ope ner can be co ntrolled with a Garage Door Receive (sold separately). The Control Panel can control up to 5 Control Modules / Garage Door Receivers.
The control panel continuously monitors the system status as well as all the sensors status. It will monitor occurrences such as triggered sensors, low battery sensors, malfunction sensors, or phone line failure etc.
Note: - The control panel cannot be armed if there are triggered sensors. Make sure all sensors are in closed position, i.e. (close all doors, windows, no movement should be detected etc). - The control panel can be armed if there are sensors with low battery or failure warning.
Disarming a triggered control panel If "System Panic" is announced from the control panel after it has been disarmed , that means the alarm was triggered when it was in armed mode. Follow the procedures below to set the control panel back to standby mode.
– 20 – OPERATION Panic Pressing the panic button on the control panel will cause the siren to sound and outgoing calls will be made to the pre-programmed phone numbers, “System Panic” will also be announced. This can be used in any emergency situation.
When sensor failure occurs, try the following: 1. Check if the sensor is located at where it should be, and whether there is any physical damage to the sensor. 2. If the failed sensor is not physically damaged, try to activate the sensor and see if the control panel reacts to such activation.
Keychain Remote (Sold separately) The battery of the keychain remote (Alkaline, Type 23A, 12V) needs to be replaced when either one of the followings occurs: 1. The LED on the keychain doesn’t flash or on when a key is pressed; or 2. The operating range starts to decrease.
Receiving the Emergency Call If you are on the list as one of the recipients of the emergency call, you should read the f ollowing instructions carefully. You should also notify all the persons you will be calling so they know how to react when they receive the emergency call.
Remote Operation by Telephone The control panel can be operated while you are away from home. You can have access to the control panel with any touch tone phone to perform a variety of operations, listed below.
® Table 1: Remote Phone Operations COMMUNICATION SYSTEM OPERA TION PHONE COMMAND DESCRIPTION Turn on device x [x] = 1 to 5 Turn off device x x = [1 to 5] Check system status Arm Disarm Disconnect x +[*] x +[#] [8]+[#] [7]+[#] [9]+[#] [0]+[#] Turn devices on will hear [Device X On] .
ADVANCED PROGRAMMING Advanced Programming allows users to customize the control panel to react differently under different conditions. Features such as: - When a sensor is triggered, the control panel.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il SkyLink AM-002/ML-001 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del SkyLink AM-002/ML-001 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso SkyLink AM-002/ML-001 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul SkyLink AM-002/ML-001 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il SkyLink AM-002/ML-001, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del SkyLink AM-002/ML-001.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il SkyLink AM-002/ML-001. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo SkyLink AM-002/ML-001 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.