G8860_4 Installation Manual NZ.doc IB1100, IB850, IB600 Installation Manual NEW ZEALAND EDITION Important: The appliance shall be insta lled in accordance with; • This installation instruction bookl.
G8860 _4 Installation Manual NZ 2 Note: THERE ARE FOUR MAIN THINGS TO CONSIDER BEFORE INSTALLATION • Cavity Dimensions & Clearances • Coupling of Flue to Fire • Coupling of Gas Lines to Fire • Fixing the Fire to the Cavity The sequences you choose to do these tasks will vary on your individual scenario.
G8860 _4 Installation Manual NZ 3 Contents: S e c t i o n : • Product Description 1.0 • Creating the Cavity 2.0 • Ventilating the Cavity 3.0 • C a v i t y B a s e 4.0 • H e a r t h 5.0 • Raised Installations Up a Wall 6.0 • W a l l L i n i n g s 7.
G8860 _4 Installation Manual NZ 4 565 580 615 270 130 40 = = 587 795 690 555 650 550 510 Masonary Onl y 165 350 1.0 Product Description: The Escea IB1100, IB850 and IB600 gas fires are des igned to be built into a cavity. These appliances are flued conventio nally via Ø100mm flue system.
G8860 _4 Installation Manual NZ 5 C A B 2.0 Creating the Cavity: The dimensioned drawing below shows the size of the opening that must be created to keep combustible materials at the r equired distance from the heater. Note: It is not necessary to line the side, top or ba ck o f the cavity.
G8860 _4 Installation Manual NZ 6 300 200 100 1 5 0 effect on the gas fireplace. This may result in nuisance shut down and give an E3 error code on the handheld remote. IMPORTANT: For the power flue installation, a singl e Ø120mm hole, covered with a suitable louvre plate, centrally located at the base of the cavity is required.
G8860 _4 Installation Manual NZ 7 8.0 Mantle Clearance: Please refer to the diagram on the previous page. Mantles or prot ruding ledges mounted above the heater that are made from combustible materials, must not extend outside of the dimensions shown.
G8860 _4 Installation Manual NZ 8 1260mm 2380mm 11 9 0 m m 560mm 596mm 596m m 1683mm 9.3 IB1100 minimum corner install dimensions: 10.0 Pow er Supply: Whilst the cavity is being created considerati on should be given to appropriate location of a standard 3 pin, EARTHED 240V power outlet.
G8860 _4 Installation Manual NZ 9 DESIGN EXAMPLE ONL Y LONG SECTION THROUGH FLUE ENCLOSURE Scale: 1:10 Angle fixing bracket supplied with flue kit . 100 150 25 25 Seal - De ck T ight or simil ar 5 0 0.
G8860 _4 Installation Manual NZ 10 FROM NZS 5261:2003, please ensure compliance to all other relevant sections of this code. 2.6.13 FLUE TERMINALS 2.6.
G8860 _4 Installation Manual NZ 11 12.3 IB1100: The IB1100 Outer Skin Kit has 4 possible ent ry points for solid gas pipe, on the four corners of the kit. Each is sealed by a ‘kno ck-out’. Remove only the knock-out which you require, and place the supplied rubber plug into the hole.
G8860 _4 Installation Manual NZ 12 13.2 Attach the Rear to the Sides and Base: The rear panel fits inside the Side and Base panels, make sure the flanges on the Side and Base panels are on the outside. The two holes on the Rear panel go towards the bottom.
G8860 _4 Installation Manual NZ 13 15.0 Insert the Flue Supp ort Bracket (IB1100 Only): Place the Flue Support Bracket in line with the flue hole on the Top-Rear panel. The Flue should be ready to pass through the hole in the OSK and mate with the Gas Fire Spigot.
G8860 _4 Installation Manual NZ 14 Step 2: Lift out glass and place it carefully aside. 18.0 Connecting Flue to Heater: This is a 7 step process and is performed after the heater has been pushed into position in the cavity and before fascia panels have been fitted.
G8860 _4 Installation Manual NZ 15 It should now be possible to reach up from inside of the heater and connect the flue to the heater’s flue spigot as per sections 18.1 and 18. 2. This junction should be made fast with both sealant and a fixing screw.
G8860 _4 Installation Manual NZ 16 20.0 Fixing the Heater to the Base and Wall: There are several ways that the heat er can be fixed against movement: It is a requirement that this heater be securely fa stened to the wall and base.
G8860 _4 Installation Manual NZ 17 22.0 IB850 & IB60- Locating the Log Set After Replacing the Fire Box: 1) Remove packaging from around log sets 2) Place rear log (long rectangular one) into pos ition by inserting it in behind retainer brackets at rear of fire box.
G8860 _4 Installation Manual NZ 18 IB850 Log & Template Position 4) Line up some of the coals that have been supplied with this appliance, along the burner holes in front of the logs. 5) Scatter the remaining coals around to fill the empty spaces left over.
G8860 _4 Installation Manual NZ 19 22.1 IB1100- Locating the Log Set Afte r Replacing the Fire Box: 1) Remove packaging from around log sets 2) Place 2 x rear logs (long rectangular ones) in to position by inserting in behind retainer brackets at rear of fire box.
G8860 _4 Installation Manual NZ 20 22.2 Log Replacement: The fire unit should never be used with broken logs . Turn off the fire and allow the unit to cool before removing the glass to carefully remo ve the logs. If for any reason a log should need replacement, you must use the proper replacement log.
G8860 _4 Installation Manual NZ 21 pressures listed on the table below then rea ssess installation pipe size or upstream regulator settings. Replace inlet test point screw.
G8860 _4 Installation Manual NZ 22 25.0 Fitting the Fascia Panels: To avoid scratches or knocks to the fascia panels of this heater they must be fitted at th e complete conclusion of the installation process. It may be necessary to use the outer fascia to initially locate the heater but then remove it again so that there is no chance of damage.
G8860 _4 Installation Manual NZ 23 25.1 When installing a 4 sided fascia ensure that the clips that the outer fascia screw into are at the bottom of the slot on whic h they are attached as shown below.
G8860 _4 Installation Manual NZ 24 27.0 Normal Operating Sounds and Smells; Note: Each time the fire is lit from cold the glass may fog up with condensation. This is normal and the condensation will disappear within a few minut es once the glass heats up.
G8860 _4 Installation Manual NZ 25 28.0 Installation Check List: 1 Ensure there is adequate ventilation in the cavity. 2 Ensure the spark electrodes are correctly positioned. 3 Operating pressure checked wi th heater running on full (all burners operating) and all other gas appliances in the house s w i t c h e d o n .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sigma IB850 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sigma IB850 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sigma IB850 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sigma IB850 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sigma IB850, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sigma IB850.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sigma IB850. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sigma IB850 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.