Document No. 14811 January 2005 DA5320 8-CHANNEL AES AUDIO MIXER/ ROUTER MODULE.
14811 • January 2005 • Front Matter Page ii.
14811 • January 2005 • Front Matter Page iii SIGMA ELECTRONICS's products are certified to comply with the regulations and recommendations of several certifying agencies. For complete details, as well as copies of the certification documents, please visit our website at www.
14811 • January 2005 • Front Matter Page iv CUSTOMER APPRECIATION STATEMENT SIGMA ELECTRONICS would like to take this opportunity to compliment you on your intelligent selection of high-quality audio or video equipment. It is our goal to provide the highest quality products and unparalleled service to all of our valued customers.
14811 • January 2005 • Introduction/overview Page 1 INTRODUCTION/OVERVIEW The multi-function Sigma DA5320 8 Channel Mixer/Router module is a member of the Sigma 5000 series OctaStream ™ product line.
14811 • January 2005 • Receiving Inspection and Unpacking Page 2 RECEIVING INSPECTION AND UNPACKING By the time you have found and opened this manual, you have already begun to unpack the shipping container.
14811 • January 2005 • System Components Page 3 SYSTEM COMPONENTS Frame The DA5320 module is engineered to operate in a Sigma S5000 Signal Management Frame. This frame provides all the necessary interface components and power for opera- tion of the DA5320 module.
14811 • January 2005 • Module Installation/Removal Page 4 MODULE INSTALLATION/REMOVAL The DA5320 may be installed in any module slot in a S5000 Signal Management System frame.
14811 • January 2005 • Module Installation/Removal Page 5 RP303 BACKPLANE CONNECTOR ASSIGNMENTS - DA5320 RP302 BACKPLANE CONNECTOR ASSIGNMENTS - DA5320 A B C D E F G H I J OCTABUS OUTPUT OCTABUS I.
14811 • January 2005 • Operation Page 6 OPERATION Front Panel Controls/Displays The front panel, shown below, has three distinct functional areas - the Indicator LED’s under the OctaStream logo on the right side; the switch controls, mostly on the left side and the 7-segment display in the middle.
14811 • January 2005 • Operation Page 7 CONTROLS SELECT BUTTON The Select button is used to progress to a lower menu level. If pressed repeat- edly, the display will always return to the idle display (see below) without making any changes to any menu items .
14811 • January 2005 • Operation Page 8 Display Activation To access menus when the Idle Display is showing, press any button. Status Check To check the current status of any parameter, activate the menu display and navigate through the menu to the edit screen for the parameter of interest.
14811 • January 2005 • Operation Page 9 Configurable Parameters/Menu Items Note: What follows is a discussion of the configurable parameters in the DA5320. To view a diagram of the flow of the menu structure with simple operating instructions, see the section of the manual entitled MENU STRUCTURE that follows this discussion.
14811 • January 2005 • Operation Page 10 sent to the ouput may be adjusted immediately prior to being sent to the output connector. These features are detailed in the Output Channel Assignment/Mixing/Gain Control section below. The DA5320 has two additional features that are available to the user to assist in providing quality I/O routing.
14811 • January 2005 • Operation Page 11 Output Channel Assignment/Mixing/Gain Control The sub-menu item is used to configure the routing matrix of defined inputs to spe- cific physical output connectors and the mixing operation of the DA5320. It is located under the main menu item.
14811 • January 2005 • Operation Page 12 any valid NTSC or PAL video signal or AES Digital Audio. The DA5320 will match its ouptut signal timing to be synchronized to this reference. To have the DA5320 match its output signal timing to the internal reference the menu setting must be set to ON.
14811 • January 2005 • Operation Page 13 N on -V olatile C onfiguration P arameter S torage All configuration data can be stored in the FlashROM to preserve it in the event of a loss of power. On power-up, all settings will be returned to their previous settings.
14811 • January 2005 • Menu Structure Page 14 MENU STRUCTURE The following graphic display of the menu structure is provided to give the user an overall view of the commands that are accessible via the front panel controls. Detailed explana- tions of each parameter have been provided above.
14811 • January 2005 • Menu Structure Page 15 Note: around character indicates character will be blinking - data entry mode active ..
14811 • January 2005 • Menu Structure Page 16 SAVE CONFIG TO FLASH DIAGNOSTICS (Status Only) RESET Reset Board Reset All Reset Outputs Reset Inputs Current ON/OFF setting shown.
14811 • January 2005 • Menu Structure Page 17 NOTES.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sigma DA5320 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sigma DA5320 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sigma DA5320 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sigma DA5320 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sigma DA5320, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sigma DA5320.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sigma DA5320. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sigma DA5320 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.