OPERATION & MAINTENANCE MANUAL AC880 Refrigerant Handling System Manual P/N 035- 80749-00.
TA BLE OF CONTENTS A C880 B e f o r e U s i n g t h e A C 8 8 0 ..................... 2 S a f e t y P r e c a u t i o n s .......................... 2 U s i n g t h e A C 8 8 0 ........................... 3 S e t u p ..................................
Page 2 BEFORE USING T HE A C880 Check for any shipping damage. Place a claim with carrier if damage is disc overed. DO NOT USE A DAMA GED UNIT. Complete and retur n the Warr anty Card to ac tivate te chnical s upport ser vice and w arra nty coverage.
Page 3 USIN G T HE A C880 Note: The purpose of this discus sio n is to fa m iliarize the user with t he features and functions of the AC880 Refrigerant Handling Station.
Page 4 SETUP 1 Low Pressure Gauge 7 Oil Charge - High Side 13 Fill Port 2 Keypad 8 Red Hose - High Side 14 Refrigerant Cylinder 3 Power Switch 9 Blue Hose - Low Side 15 Y ellow Hose w/Anti-blowback 4 .
Page 5 N N N N N N N N N N N N EXTREMELY IMPOR TA NT N N N N N N N N N N N N Always connect Y ellow Hose (15) to Cylinder (14) first and then connect other end of hose with anti-blowback valve to Fill Port (13) on AC880. WEIGHT = XX.X LB AUTOMA TIC ? # >>>> WEIGHT = XX.
Page 6 WEIGHT = XX.X LB AUTOMA TIC ? # > WEIGHT = XX.X LB RECYCL E ? # ENTER RECYCL E HOLD TIME XX MI N # >< ENTER CHECK HO SES START ? # ENTER WEIGHT = XX.
Page 7 DRA IN RECOVERED OIL Oil is separated from the recove re d refrigerant and MUST be removed following EACH Recover/ Recycle procedure to determine the amount (if any ) necessary to add into the A/C Sy stem as follows: Note: The AC880 must be connected to pow er source.
Page 8 WEIGHT = XX.X LB AUTOMA TIC ? # >> WEIGHT = XX.X LB VACUUM ? # ENTER * A/C HAS PR ESSURE GO TO RECY CLE # ENTER ENTER VA CUUM TIME XX MI N # >< ENTER PEFORM L EAK TEST ? Y/N # < .
Page 9 WEIGHT = XX.X LB AUTOMA TIC ? # >>> WEIGHT = XX.X LB CHARGE ? # ENTER ENTER CH ARGE AMOUNT = XX.X LB # >< ENTER * LOW LEVEL , GO T O FILL CY LIND ER # ENTER CHECK H IGH- LOW CHARGE S WITCH # ENTER WEIGHT = XX.X LB CHARGI NG CHARG E COMP LETE EVAC HOS ES # ENTER CHA RGE 1.
Page 10 WEIGHT = XX.X LB AUTOMA TIC ? # ENTER RECYCL E HOLD TIME XX MI N # >< ENTER ENTER VA CUUM TIME XX MI N # >< ENTER PEFORM L EAK TEST ? Y/N # < ENTER ADD OIL ? Y/N # < ENTER ENTER CH ARGE AMOUNT = XX.
Page 11 WEIGHT = XX.X LB COMPRE SSOR OFF * HIGH PR ESSU RE SEE MAN UAL ** CYLIND ER FULL GO TO CHAR GE # TIME LE FT=X X MIN PUMP ON PUMP OFF XX MIN CONTIN UE ? # ENTER ADD OIL NO W CONTIN UE ? # ENTER WEIGHT = XX.
Page 12 WEIGHT = XX.X LB AUTOMA TIC ? # >>>>> ENTER WEIGHT = XX.X LB SETUP ? # ENTER FILTER H OURS= XX.X HOU RS > TOTAL R ECYC LED= XXXX.X K G > TOTAL C HARG ED= XXXX.X K G > A CCESS ST ORED DA TA 1. Set up the AC880 and t urn the Main Power Switch ON.
Page 13 WEIGHT = XX.X LB AUTOMA TIC ? # >>>>> ENTER WEIGHT = XX.X LB SETUP ? # Calibration Switch WEIGHT = XX.X LB CHARGI NG > OVER CH ARGE AMOUNT = X.XX KG # >< ENTER SET OVER CHA RGE A MOUNT 1. Remove the front panel of the AC880.
Page 14 SCHEDULED MA INT ENA NCE DA IL Y... Che ck the oil le vel in t he Vacuum Pump while the pump is running. The Vacuum Pum p Oil Level Sight Glass is visible thr ough a hole in the Lower Rear Panel of the AC880. The oil l evel s hould be at the “half-way” point of the glass.
Page 15 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 360-81555-00 Manifold Assy 880 120V 2 024-80037-00 Contactor ½ HP (120V) 3NO/1N C 3 024-80066-00 Rocker Swi tch SPDT Visired N on-lig hted 4 360-803.
Page 16 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 026-80077-00 Combo Filter 3/8 Fl are (Long) 2 360-81192-00 Compressor Inlet Tube Assy 3 360-81197-00 Accumulator Assy 4 360-81356-01 Compressor Assy .
Page 17 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 024-80040-00 Rocker Swi tch SPDT (on-on) Amber 125V 2 024-80060-01 Circuit Boar d 120V 3 026-80065-03 Gauge 30"-120 Psig 1/4 MFL 3.
Page 18 T ROUBLESHOOTING FILL CYLINDER PROCEDURE 1) The cy linder of new refrigerant should be at ambient temperature or great er for best performance of the Fill Cylinder procedure. Make sure the cy linder was not recently moved from an air-conditi oned storage ro om to a w arm w ork a rea .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sharp AC880 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sharp AC880 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sharp AC880 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sharp AC880 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sharp AC880, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sharp AC880.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sharp AC880. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sharp AC880 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.