Manuale d’uso / di manutenzione del prodotto ION8800 del fabbricante Schneider Electric
Vai alla pagina of 36
PowerLogic ® ION8800 Energy & Power Quality Meter Installation Guide 05/2007.
.
3 Danger This sym bol indica tes the pr esence o f dangerou s voltage within and o utsid e the product enclosure that may constitute a risk of electric shock, seriou s injury or deat h to person s if prope r precaut ions are not follo wed.
4 Network Compatibility Noti ce for the Internal Modem The internal modem in meters equipped with this option is compatible with the te lephon e systems of most countries in the world. Use in some countri es may require modification of the internal mode m’s initialization strings.
© 2007 Schne ider Electric. All rights res erved. 5 ION8800 Models Available Options I/O Options Before You Begin Before installing the mete r, familiarize yourself with the steps in this guide and read the safety precautions prese nted on the “Installat ion Considerations” page.
6 © 2007 Schneider Electric. All rights rese rved. Meter Overview Navigation Buttons Meter Front (Cover Closed) Meter Back Cover Seal Meter Front (Cover Open) Navigation Buttons Battery Cover Display.
© 2007 Schne ider Electric. All rights res erved. 7 Front Panel Button Functions ALT / ENTER : Press this butt on once to enter ALT mode. Press and h old to enter Setup mode. In Setup mo de, press this button to accept changes. NAVIGATION : Press the UP / DOWN arrow buttons to highlight menu items, or increment / decrement numbers.
8 © 2007 Schneider Electric. All rights rese rved. Unit Dimensions Meter dimensions conform to DIN st andard 43862. 38.4 mm (1.51“) 260.0 mm (10.24“) Front View of Meter Side View of Meter Front of Rack View 132.2 mm (5.21“) 202.1 mm (7.96“) 482.
© 2007 Schne ider Electric. All rights res erved. 9 Essailec Connections Voltage, current, power supply, I/O and communication connections are made via the Essa ilec conne ctor on the rear of the meter. Meters can be ordered with mul tiple connector configurations.
10 © 2007 Schneider Electric. All rights rese rved. Order Option A Circuit & Pinout Diagrams Meter Rack A B C D E Code 15 Code 17 Code 15 Code 13 Code 07 C ode 05 Code 03 C ode 01 This pinout drawing details the various pins on the meter side of the connector.
© 2007 Schne ider Electric. All rights res erved. 11 Order Options A/B/C Essailec Connector Arrangement Meter Port Essailec Connector Pin Description Current Measurement Inputs I11 A01 standard I12 A.
12 © 2007 Schneider Electric. All rights rese rved. Order Options D/E Circuit & Pinout Diagrams A B C D Code 15 C ode 15 Code 15 Code 07 Code 03 Code 05 Meter Rack This pinout drawing details the various pins on the meter side of the connector. The table below maps the pins to their corresponding inputs and outputs in the meter.
© 2007 Schne ider Electric. All rights res erved. 13 Order Options D/E Essailec Connector Arrangement Step 1: Mount the Meter Meter Batter y Considerations The meter’s battery life ex pectancy de pends on both temperature and the amount of time the meter is without po wer.
14 © 2007 Schneider Electric. All rights rese rved. Environmental Specifications (IEC62052-11) Installation D ANGER Do not power up the meter un til the ground terminal is connected -- risk of electric shock. 1. Connect the ground terminal on the rear of the meter to a good earth ground on the rack, using a 3.
© 2007 Schne ider Electric. All rights res erved. 15 Step 2: Wire the Digital I/O Form C Digital Output: Mechanical Alarm Relay Form C Digital Output: Solid State Relay Outputs DO1 - DO4 Form A Digit.
16 © 2007 Schneider Electric. All rights rese rved. Step 3: Wire the Voltage and Current Inputs V oltage Inputs Current Inputs: High Current Option Current Inputs: Low Current Option N OTE The appropriate Volts Mode sett ing is included with each wiring diagram.
© 2007 Schne ider Electric. All rights res erved. 17 4-Wire Wye, 3-Element, Direct Connection Diagram 288 V L-N / 500 V L-L max. VOLTS MODE = 4W-Wye 4-Wire Wye, 3-Element, 3 PTs Conn ection Diagram Use PTs for voltages over 288 V L-N / 500 V L-L. Wye (Star) wiring for PT primaries and secondaries.
18 © 2007 Schneider Electric. All rights rese rved. 3-Wire Solid-Grounded Wye, 3- Element, Direct Connection When the common or star point of a 3-wire Wye system is grounded, the meter may be connecte d directly without using PTs, provided that the phase voltages are with in the meter’s range.
© 2007 Schne ider Electric. All rights res erved. 19 3-Wire Delta, 2½-Eleme nt, 2 PTs & 3 CTs Use PTs for voltag es over 500 V L-L VOLTS MODE = Delta Single Phase Connection Diagram 288 V L-N / 500 V L-L max. Use PTs for higher volt ages. VOLTS MODE = Sing le Using Potential Transformers LINE LOAD LINE LOAD PF = 0.
20 © 2007 Schneider Electric. All rights rese rved. Step 4: Wire the Communications ION8800 meters are equi pped with one standard op tical port. Other communications ports are available as options.
© 2007 Schne ider Electric. All rights res erved. 21 Ethernet Connections (optional module) 10Base-T 10Base-FL (Fiber) N OTE E t h e r n e t co n n e c t i o n s h o u l d b e m ad e t o e i t h e r t h e F i b e r p o r t o r R J 4 5 p o r t , n o t both, or communications conflicts may result.
22 © 2007 Schneider Electric. All rights rese rved. Step 5: Wire the Power Supply ION8800 meter power supply connec tions are found on the Essailec connector.
© 2007 Schne ider Electric. All rights res erved. 23 The following ta ble lists all set tings that can be confi gured via the front p anel, with the me ter cover seal in place. Menu Setting Description Range (V alues) Default Basic Setup Vo l t s M o d e The power system ’s configuration – WYE, DEL T A, etc.
24 © 2007 Schneider Electric. All rights rese rved. COM2 Protocol Specifies which protocol is active ION , Modbus RTU , Modbus Master 3 , DNP , DLMS, EtherGate, ModemGate, GPS: T ruetime/Datum GPS: A.
© 2007 Schne ider Electric. All rights res erved. 25 1 A baud rate of 300 bps is only i ntended for paging applications. 2 Serial number = PA-030 2 B 222 -01, Unit ID = 2222 3 Available on ION8800A and B meters only.
26 © 2007 Schneider Electric. All rights rese rved. The following ta ble lists all s ettings that can be configured using t he ALT CONFIG menu (not av ailable wh en meter cover is sea led). 1 After a meter is unlocked, it automatica lly relocks if you do not perform any configuration for 30 minutes.
© 2007 Schne ider Electric. All rights res erved. 27 WYE - 123 Rotation Applicable Volts Mode = 4W-WYE and 3W-WY E WYE - 132 Rotation Applicable Volts Mode = 4W-WYE and 3W-WY E I1 I2 U1 I2 I3 I1 I3 U.
28 © 2007 Schneider Electric. All rights rese rved. 2 Element (3Wire) DELT A - 123 Rotation Applicable Volts Mode = D ELTA 2 Element (3Wire) DELT A - 132 Rotation Applicable Volts Mode = D ELTA I1 I3.
© 2007 Schne ider Electric. All rights res erved. 29 Step 9: View Meter Data NORM mode Use the Up and Down buttons to scroll through NORM mode display screens. ALT mode Press the Alt/Enter button once for ALT display modes. Press the Up or Down buttons to scroll through displays.
30 © 2007 Schneider Electric. All rights rese rved. N OTE PB = Previous Billing pe riod. TEST Mode T o Enter TEST Mode N OTE The meter alwa ys returns to NORM mode after exitin g TEST mode.
© 2007 Schne ider Electric. All rights res erved. 31 Replacing the Battery The battery in the ION8800 meter keeps the real time clock running when supply power is lost. Replace the battery if the meter has b een stored fo r an extended period of time without power (longer than two years).
32 © 2007 Schneider Electric. All rights rese rved. Meter Security Security features depend on the meter orde ring options. See below. All ION8800 meters Standard security includes traditiona l anti-tamper mechanical sealing points on the meter case and cover.
© 2007 Schne ider Electric. All rights res erved. 33 The meter incorporates se aling bars an d chassis screws with through-holes, through which traditional lead/wire se als can be inserted. Whe n utilized, these lead/wire seals effectiv ely prevent unautho rized personnel fr om gaining access to meter in ternals or to buttons under the cover.
34 © 2007 Schneider Electric. All rights rese rved..
.
ION8800 Instal lation G uide Schneider Electric 2195 Keati ng Cross Road Saanichton, BC Canad a V8M 2A5 www .powerlog ic.com Electrical equipment should be installed, o perated, serviced , and maintain ed only by qualified personn el. No responsibili ty is assumed by Schneide r Electric for any consequences arising out of the use of this m aterial.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Schneider Electric ION8800 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Schneider Electric ION8800 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Schneider Electric ION8800 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Schneider Electric ION8800 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Schneider Electric ION8800, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Schneider Electric ION8800.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Schneider Electric ION8800. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Schneider Electric ION8800 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.