Manuale d’uso / di manutenzione del prodotto 1108-60 del fabbricante Saunatec
Vai alla pagina of 13
Installation & Operation Instructions 421 1-86-G 09-23-05 1 314 SKLH 20C SAUNA HEA TER 1 108-24, 1 108-46 & 1 108-60 Saunatonttu 2.4, 4.6, & 6.0 kW Read all instructions carefully before installation. Please leave all instructions with the owner .
Installation & Operation Instructions 421 1-86-G 09-23-05 2 314 SKLH 20C Rad. 12 3 4 " 7" From th e corner t o screw h ole 19 11 16 " 30" min. 5 1 2 " Max. 81" min. 1 1 4 " Min. 1 2 " M in. DIAGRAM 2 DIAGRAM 1 13" Example of an installation in depression of a wall.
Installation & Operation Instructions 421 1-86-G 09-23-05 3 314 SKLH 20C Fire sprinkler systems used inside any sauna room should be properly rated for sauna room temperatures. Do not pour chlorinated pool or spa water on heater . Excessive water use on heater may cause damage and void warranty .
Installation & Operation Instructions 421 1-86-G 09-23-05 4 314 SKLH 20C This heater is always ready and is designed to keep the rocks in the rock chamber hot at all times using a “Continuous Power” setting of 100 W atts, 200 W atts or 300 W atts.
Installation & Operation Instructions 421 1-86-G 09-23-05 5 314 SKLH 20C R ule of 2 0 0 90 100 110 120 130 140 150 160 170 180 190 10 20 3 0 4 0 5 0 6 0 70 80 90 1 0 0 % o f H u m id ity Temperatu.
Installation & Operation Instructions 421 1-86-G 09-23-05 6 314 SKLH 20C SECTION 7: OPERA TION For health and fire safety , never attempt to alter or bypass the controls. This heater has a 60 minutes timer built into the programming. The rock temperature is preset by the manufacture.
Installation & Operation Instructions 421 1-86-G 09-23-05 7 314 SKLH 20C SINGLE PHASE WIRING DIAGRAM: Saunatonttu 6.0 kW heater Heater T ype: 1 108-60 DIAGRAM 5.
Installation & Operation Instructions 421 1-86-G 09-23-05 8 314 SKLH 20C SINGLE PHASE WIRING DIAGRAM: Saunatonttu 4.6 kW heater Heater T ype: 1 108-46 DIAGRAM 6.
Installation & Operation Instructions 421 1-86-G 09-23-05 9 314 SKLH 20C SINGLE PHASE WIRING DIAGRAM: Saunatonttu 2.4 kW heater Heater T ype: 1 108-24 DIAGRAM 7.
Installation & Operation Instructions 421 1-86-G 09-23-05 10 314 SKLH 20C DIAGRAM 8 DIAGRAM 9 Exhaust Fresh Air DIAGRAM 10 Electrical access for the heater is on the back of the heater .
Installation & Operation Instructions 421 1-86-G 09-23-05 11 314 SKLH 20C Three metal placards are included in the Installation Instruction Enve- lope packaged with the Saunatonttu Heater . The CAUTION placard must be attached to the interior wall of the sauna room directly above the heater where it is visible to the bather .
Installation & Operation Instructions 421 1-86-G 09-23-05 12 314 SKLH 20C The sauna heater has a built-in High Limit control, which automatically turns off the heater if the temperature inside the sauna room rises to an abnormally high level. T o reset the high limit control, let the heater cool and then push the button.
Installation & Operation Instructions 421 1-86-G 09-23-05 13 314 SKLH 20C VENTILA TION V entilation shall be provided in a sauna, the air should be changed about 6 times an hour . This can be achieved by making a vent opening (fresh air inlet) in the sauna wall directly below the heater .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Saunatec 1108-60 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Saunatec 1108-60 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Saunatec 1108-60 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Saunatec 1108-60 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Saunatec 1108-60, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Saunatec 1108-60.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Saunatec 1108-60. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Saunatec 1108-60 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.