Manuale d’uso / di manutenzione del prodotto VCC-WB4000P del fabbricante Sanyo
Vai alla pagina of 68
INSTRUCTION MANUAL Network Camera VCC-WB4000P Abou t this manua l Befor e inst alli ng a nd usi ng t his un it, please rea d th is ma nual c aref ully.
Contents Precautions ................................................. 2 Features ..................................................... 3 Accessories ................................................. 3 Operating environment ...........................
Precautions In case of p roblem Do not use the camera if smoke or a st range odour comes from the unit, or if it seem s not to function correctly. Disconnect the power cord immediately, and consult your deal er (or a Sanyo Authorized S ervice Centre).
Features Web Se rver Funct ion This camera is equipped with a web server function. The camera can be accessed using a computer ’ s web browser in order t o view the camera images. In addition, up t o a maximum of 16 users can simultaneously access a single camera on the network.
Operating environment The camera requires the f ollowing conditions to operate. • OS: In this manual, the Microsoft ® Windows ® 98 operating system, the Microsoft ® Windows ® Millennium Edition .
Name and Function of Each Part PC CARD RS-232C ALARM IN OUT MODEM PC COM D/N IN AC24V DC12V GND 1 2 ETHERNET POWER MONITOR OUT 5 6 7 1 2 3 3 CLASS 2 WIRING 4 1 Lens mount c ap Attach this cap to protect the lens mounting section. When using the cam era, remove the cap and attach the aut omatic iris-type lens (sold separately).
Name and Function of Each Part CLASS 2 WIRING PC CARD RS-232C ALARM IN OUT MODEM PC AC24V DC12V GND 1 2 ETHERNET POWER MONITOR OUT 8 H G JF I 9 COM D/N IN 8 Link in dica tor This indicator illuminates when the cam era is connected to a network. It flashes whi le data transmission is in progress.
Attaching the Lens Use a DC-type automatic iris-type l ens (sold separately). 1 Remove the lens mount cap. 2 Attach the CS mount-type lens. Note: The “ L ” part of the lens should be 5 mm or less in length. If a l ens that does not conform to this standard is used, it will not be possible to attach the lens correctly.
Flange Back Adjustment The flange back is the distance between the lens (sold separat ely) and the image capturing surf ace of the camera. It is adjusted at the time of shipment from the fact ory to accommodate the t ypes of lenses that are generally assumed t o be in use.
Connections Turn off the power for all equipment before making any connections. Basic Connections 1 Connect the camer a to a computer. Connect a cable between the ETHERNET connectors of the camera and the computer. Use a crossed wire-type Ethernet cable.
Connections Connec ting to a LAN Use an Ethernet cable to connect the ETHERNET connector of the camera to the LAN ’ s Ethernet switching hub. ☞ Use a straight-type Ethernet cable.
Network Camera (Wired LAN) Settings In order to use the cam era as a network camera, you m ust make the following settings in t he order given. 1 Installation of Plug-in Software to the Computer (p. 12) Insert the contents of the supplied setup CD-ROM to the computer.
Network Camera (Wired LAN) Settings 1 Insta llat ion of Pl ug-in S oftw are to th e Comp uter Install the plug-in soft ware (on the setup CD-ROM) onto t he computer that is to be used. Installing the plug-in software makes it possible to view live images from network cameras using the com puter ’ s web browser.
Network Camera (Wired LAN) Settings 8 Type in your usern ame and organization name, and th en click the [Next] button. 9 Click the [Install] button. Installation of the sof tware will start and the window display will change to show the installation progress.
Network Camera (Wired LAN) Settings Brows er Setti ngs Check that the Security settings for Microsoft Internet Explorer are set as described below. Select Internet Options from the Tools menu, click the Security tab and then click the Custom Level button to display the set tings.
Network Camera (Wired LAN) Settings 2 W ired LAN Settings Once the plug-in software has been installed, use the computer ’ s web browser t o access the camera. Note: The network camera handles large volumes of image data that has been compressed into JPEG2000 format.
Network Camera (Wired LAN) Settings Initial Camera Screen The initial screen is displayed once t he network camera and the computer have been set. The initial screen contains the butt ons that are required for m aking various settings, and it al so shows live images from the network camera t hat have been compressed int o JPEG2000 format.
Network Camera (Wired LAN) Settings 2 Menu select b uttons The live image display area and set ting area changes when you cli ck on one of these buttons. • [LIVE VI EW] butt on Live images can be monitored. • [VIEW FRAME] button Sets the live image display area to a fixed image size (720x480).
Network Camera (Wired LAN) Settings 6 ALARM DATA indicator • Lit red: (alarm recording imag e playback is possible) Internal memory or expanded memory (installed in the PC card sl ot) is filled by alarm recording images.
Network Camera (Wired LAN) Settings G RESOLUTION and EXPANSION set tings (default setting s: 640x480, x1) • Select the image resolution from the drop-down list box. The volume of data transmitted will be larger when a higher resolu tion is s elect ed.
Network Camera (Wired LAN) Settings 3 NETWORK SET Se tting s These settings are used in order to connect the cam era to the network. After these settings have been completed, you may also have to make wireless LAN settings or PPP settings.
Network Camera (Wired LAN) Settings 7 MAC ADDRESS display This shows the Mac address for the camera. Note: • Up to a maximum of 16 individual users can access a single camera on the network at the same time. However, only one user out of this maximum of 16 users can be accessing at Operator or Administrator level at any one time.
Network Camera (Wired LAN) Settings Viewing Live Images Without Typing In a Usern ame or Password (ID1 only) Normally you need t o type in a password at the password entry screen in order to display the live image screen. However, if you make the settings described below, you can view t he live image screen without having to t ype in a password.
Network Camera (Wired LAN) Settings Access Level Settings When operating the network came ra, you need to select an access level to either l imit operations to only the monitoring of l ive images or to allow menu set tings to be changed as well.
CLOCK SET Settings This lets you set t he camera ’ s internal clock. You can al so make settings for sum mer time. Click the [CLOCK] menu select button. The CLOCK S ET screen wil l be displayed. Set the dat e and time using the drop-down list boxes, and then click the [SET ] button.
CAMERA Settings Click the [CAMERA] menu select button. This lets you set the cam era title and adjust the images and make day/night settings in accordance with the cam era setting-up conditions. The CAMERA SET screen will be displayed. Note: If you click the [LIVE VIEW] button, the live image screen will be displayed.
CAMERA Settings 6 ELECTRONIC SHUT TER This setting is used when I RIS is set to automatic iris. Setti ng ra nge: 1/60 (default setting), 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000 7 BLC (backlight co mpensation) Available settings: • OFF (default setting): Backlight compensation is not carri ed out.
CAMERA Settings Setting the camera title 1 Move the cursor to the curr ent camera title (e.g. NET_CAM), an d delete the title. 2 Type in the new camera title (e.g. SANYO01). Note: The camera title can be up t o eight characters in length, and may include alphanumeric characters and the underscore character only.
CAMERA Settings 1 MODE This sets the DAY/NIGHT mode. Item Operation after selection Required settings AUTO (p. 29) Monitoring switches automatically between color and black & white depending on the luminance of the obj ects. 2 AGC Gain 4 LEVEL 6 BURST COLOR (p.
CAMERA Settings ☞ AUTO Mode S ettings 1 Click the [DETAIL] b utton in the DAY/NIGHT field and set MODE to “ AUTO ” . 2 Set “ AGC Gain ” to “ +12 dB ” (example). 3 Set “ LEVEL “ to “ LOW ” (example). The switching level for changing bet ween color and black & white can be set to one of three levels: LOW, MID and HIGH.
CAMERA Settings ☞ B/W Mode Settings 1 Click the [DETAIL] b utton in the DAY/NIGHT field and set MODE to “ B/W ” . 2 Set “ AGC Gain ” to “ +12 dB ” (example). 3 Click the [SET] button. This completes the B/W mode settings. Monitoring will switch to black & white according to the set conditions.
CAMERA Settings ☞ Using an IR lamp to illu minate during black & white monitoring in COLOR mod e When using CO LOR mode, connect a device such as an IR lamp to the ALARM OUT terminal and connect an infrared sensor (for forcibly switching to black & white monitoring) to the D/N IN terminal .
Alarm Settings Click the [ALARM] menu select button. The camera is equipped with t wo types of alarm function. When an outside intruder is detected, these al arm functions can be used t o record the i.
Alarm Settings 1 ALARM REC USE This function stops any motion that occurs during alarm setting. After t he alarm settings have been made, change this setting to “ USE ” so that alarms can be det ected in accordance with the settings.
Alarm Settings 9 ALARM SOUND MODE This setting causes an alarm warning to sound when an alarm is detected. If set to “ USE ” , “ BEEP OFF ” appears in the initial screen when an alarm is detected at the same time as the alarm buzzer sounds. If you cl ick this indicator, the alarm buzzer will st op.
Alarm Settings 5 ALARM RESOLUTION This sets the image size for data being recorded into the internal memory. Note: When playing back images that have been recorded at a size of 720x240, the vertical size will be adjusted so that they become 720x480 images.
Alarm Settings (Con necti on met hod) 1 Connect an i nfrared sensor or similar to the ALARM IN terminal at the rear of the camera. 2 Connect a buzzer or lamp to the ALARM OUT t erm inal . Once the connections are complete, install the sup plied ferrite core (A) to the power cord .
Alarm Settings External Alarm Sensor and Motion Detector Settings 1 Set “ ALARM REC USE ” to “ NO USE ” (example). 2 Set “ EXTERNAL ALARM ” to “ NO ” (example). 3 Set “ MOTION D ETECT OR ” to “ ON ” . The motion detector level and MOTION DETECTO R SET screen will be displayed.
Alarm Settings Motion Detector Level Sensitivity Sett ing The default setting for the m otion detector sensit ivity is “ 5 ” . The set ting can be selected from a level ranging from “ 1 ” (High) through to “ 10 ” (Low). 1 Set “ MOTION DETECTOR LEVEL ” to “ 2 ” (example).
Alarm Settings B Cont inuou s Alar m Outp ut 1 Set “ ALARM OUT ” to “ NO ” (example). 2 Set “ ALARM OUT MODE ” to “ REMOTE CONTROL ” . 3 Set “ ALARM OUT TIME ” to “ REMOTE ” , and then click the [SET] button . This comp lete s the s ettin g, so r eturn to the live image screen.
Alarm Settings Alarm Detection and Recording A U sing Only Post-alarm Record ing 1 Set “ BUFFERING AREA ” to “ (PRE/POST) 0/10 ” . When an alarm is detected, the ratio wil l be set to Pre = 0 (zero)/Post = 10. In other words, only post-alarm recording wi ll be set.
Alarm Settings Recording New Alarm Data If recording new alarm dat a into the camera ’ s internal memory, you should delete the old data that is recorded in the memory.
Alarm Settings Saving to an Expansion Memory Card If you would like t o save and play back several sets of alarm data from the camera ’ s internal memory, use a CompactFlash memory card with a capacity of 16MB or greater. CompactFlash memory cards are onl y used to store alarm data that has been recorded into the internal memory.
Viewing Live Images The initial screen (live image screen) can be accessed by starting up the computer’s web browser and pointing it to the IP address for the network camera. The live image screen wi ll then be displayed. • Live images will appear in the display area ( 1 ) while they ar e being mon itored.
Viewing Live I mages Viewing the View Frame Screen Click the [VIEW FRAME] menu select button. The menu select buttons wi ll disappear. The live images in the view f rame will be displayed at a screen size of 720x480, regardl ess of the screen size that has been set in the live image screen.
Playing Back Alarm Data Alarm detection data (when an ext ernal sensor or motion detector have been set) and alarm i mage data is automatically recorded. Moreover, this dat a is also played back in the live image screen. Playing Back Alarm Data in the Camera ’ s Internal Memory 1 Click the ALARM DATA indicator (while it is gree n or red).
Playing Back Alarm Data Playing Back Expansion Memory Card Images 1 Click the ALARM DATA indicator while it is re d or g reen. The ALARM DA TA LIST screen will be displayed, and the first i mage that was recorded will be displayed in t he PREVIEW screen.
Playing Back Alarm Data Descriptions of Alarm Operation Buttons f or Saving Data to a Computer 1 RESOLUTION This lets you change the resolution of the images. (Selection screen example) 2 FRAME RATE This sets the transmission speed for images. Available settings: BASIC, MID 1, MID 2, MID 3, HIGH 3 IMAGE No.
Playing Back Alarm Data Alarm Data Deleting 1 Click the ALARM DATA indicator while it is re d or g reen. The ALARM DA TA LIST screen will be displayed. 2 Click the check boxes to sel ect the alarm data t o be dele ted, an d then cl ick the [DELETE] button.
Saving Live Images and Alarm Images Saving Live Images onto a Computer The camera images that are being monitored can be saved as st ill images in the computer ’ s storage area in JPEG2000 format. 1 Right-click the mo use on th e image to be saved. The images will be paused and an image save pop-up menu will be displayed.
Saving Li ve Images and Alarm Images Saving All of a Single Alarm Event onto a Computer 1 Click the ALARM DATA indicator while it is re d or g reen. The ALARM DA TA LIST screen will be displayed, and the first i mage that was recorded will be displayed in t he PREVIEW screen.
WIRELESS LAN SET Settings Make the wireless LA N settings in the following order. 1 Camera wired LAN settings (TCP/IP settings) Make sure that the settings i n “ Network Camera S ettings ” (p.
WIRELESS LAN SET Settings Camera Wireless LAN Settings Make these settings after steps 1 and 2 on page 51 have been completed. 1 Click th e [WIRELESS LAN] me nu select button. The WIRELESS LAN SET screen wi ll be displayed. 2 Select “ USE ” from the [ WIRELESS LAN USE] dr op-do wn list box.
WIRELESS LAN SET Settings Description of WIRELESS LAN SET Screen 1 CURRENT CHANNEL The transmission mode (frequency channel ) that was set for t he wireless LAN device (access point) will be displayed here automatically. 2 ESS ID This is a verification code f or transmissions sent over the wireless LAN from the camera to the wireless LAN device.
PPP (Dial-up) Settings Two types of PPP settings can be made: Connecting to an “ Internet Service Provi der ” or “ Connecting fro m a computer ” .
PPP (Dial-u p) Setting s 2 Set “ CONNECT ” to “ N ” . 3 Click the [CAMERA SET ] and [RECORD MODE SET] bu ttons and make the respective setting s. 4 Click th e [LOCAL SERVER SET] button . The LOCAL S ERVER SET screen will be displayed. • LOCAL SERVER USE: Set to “ USE ” .
PPP (Dial-u p) Setting s ☞ DIAL TO PROVIDER Settings 1 Click t he [PPP] menu sel ect but ton. The PPP SET screen wi ll be displayed. 2 Select “ USE ” from the “ DIAL T O PROVIDER ” drop-do wn list box and then click the [DETAIL] button. The PPP SET (TO PROVIDER) screen will be displayed.
PPP (Dial-u p) Setting s 9 Make the following settings if required. • BAUD RATE: Normally “ 115200 bps ” • DATA SIZE: Normally “ 8 bits ” • PARITY: Normally “ NONE ” • STOP BIT: Normally “ 1 ” 10 Once you have finished changin g the settings, click the [S ET] butto n.
PPP (Dial-u p) Setting s 3 Set the following items. • LOGI N ID : Type in a username of 19 characters or less to use f or the dial-up networking settings on the computer. • PASSWORD: Type in a password of 19 characters or less to use f or the dial-up networking settings on the computer.
RS-232C Settings (RS-232C SE T) This sets the communication speed for the RS-232C connector of t he camera when the camera is connected to a computer for m aintenance and servicing. Click the [RS-232C] menu select button. The RS-232C S ET screen will be displayed.
STATUS Checking This displays information about the cam era status. Click the [STATUS] menu select button. The STATUS screen will be displayed. Note: If you click the [LIVE VIEW] butt on, the display will return t o the live image screen. 1 FIRMWARE VERSION This shows the versi on number for the camera ’ s firmware.
Glossary of Terms Cookie A system whereby a computer (HTTP server) that hosts web pages sends information that is stored by a user ’ s computer, so that when that user visits the same web page a second time, the information that has been automatically saved is transmitted back to the HTTP server.
Glossary of Ter ms MAC addr ess (Media Access Con trol address) A 12-digit hexadecimal identification number that is assigned to LAN cards and LAN boards in a computer.
Glossary of Ter ms Pre-alarm an d post-alarm recording Pre-alarm and post-alarm recordi ng involve recording data according to a selected ratio in the camera ’ s internal memory.
Troubleshooting If the camera cannot be connected If the live image screen does not appear when you type the camera ’ s IP address into the location bar of the web browser, check the following items.
Specifications Lens : CS mount Picture el ement : 1/3 i nch 420,000 pixel CCD Effective pixels : 768 (H) x 494 (V) Minimum object il lumination : 0.6 l x (F1.2, color mode), 0.03 lx (F1.2, B /W mode) White bala nce : AUT O/INDOOR/OUTDOO R/MANUAL manually selectable Electroni c shutter : 1/60 t o 1/10000 sec.
Specifi cations Dimensions Appearance and specifications are subject to change for impr ovement without notice. 136 mm 126 mm 12 mm 51 mm 59 mm 85 mm 28 mm L5AM2/XE (VCC-W B4000P) GB 2003, 6, 6 – 66.
Printed on recycled paper 1AC6P1P2682-- L5AM2/XE (0603KP -CZ) SANYO Electric Co., Ltd. Printed in Japan L5AM2/ XE (VCC-W B4000P) GB 2003, 6, 6.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sanyo VCC-WB4000P è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sanyo VCC-WB4000P - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sanyo VCC-WB4000P imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sanyo VCC-WB4000P ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sanyo VCC-WB4000P, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sanyo VCC-WB4000P.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sanyo VCC-WB4000P. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sanyo VCC-WB4000P insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.