Manuale d’uso / di manutenzione del prodotto 700 B-VENT del fabbricante Avalon Stoves
Vai alla pagina of 34
Chelan B-Vent (700 B-Vent) Gas Stove and Fireplace Insert ¥ Freestanding Stove ¥ Masonry Fireplace Insert ¥ Factory Built (Z.C.) Fireplace Insert Lis t ed WARNING : Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
P AGE 2 S AFETY P RECAUTIONS ¥ IF YOU SMELL GAS: * Do not light any appliance * Extinguish any open flame * Do not touch any electrical switch or plug or unplug anything * Open windows and vacate bui.
S AFETY P RECAUTIONS (C ONTINUED ) P AGE 3 ¥ Do not place clothing or other flammable items on or near the heater. Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near it.
P AGE 4 T ABLE OF C ONTENTS General Information Introduction & Important Information ............1 Safety Precautions ..................................2 Features & Specifications ..........................5 Stove Installation Installation Preparation .
F EATURES AND S PECIFICATIONS P AGE 5 Installation Options: ¥ Freestanding ¥ Masonry Fireplace Insert ¥ Zero-Clearance (Metal) Fireplace Insert Features: ¥ Works During Power Outages (millivolt sy.
P AGE 6 S TOVE I NSTALLATION - For qualified installers only! Installation Preparation ! This appliance must be installed in accordance with all local codes, if any; if not, follow ANSI Z223.1 and the requirements listed in this manual. Failure to follow all of the requirements may result in property damage, bodily injury, or even death.
S TOVE I NSTALLATION (C ONT .) - For qualified installers only! P AGE 7 Heater Placement Requirements ¥ Heater must be installed on a level surface capable of supporting the heater and vent ¥ Due to the high temperature of the heater, it should be located out of traffic and away from furniture an d draperies.
P AGE 8 S TOVE I NSTALLATION ( CONT .) - For qualified installers only! Vent Requirements ! Always maintain the required 1" clearance (air space) to combustible materials to prevent a fire hazard.
I NSERT I NSTALLATION - For qualified installers only! P AGE 9 Installation Preparation ! This appliance must be installed in accordance with all local codes, if any; if not, follow ANSI Z223.1 and the requirements listed in this manual. Failure to follow all of the requirements may result in property damage, bodily injury, or even death.
P AGE 10 I NSERT I NSTALLATION (C ONT .) - For qualified installers only! Re-Routing the Power Cord to the Front (continued) 2 Carefully pull on the power cord until the molex connector is exposed.
I NSERT I NSTALLATION (C ONT .) - For qualified installers only! P AGE 11 Insert Placement The Insert Must be Placed 13" into the Fireplace. Run the power cord to either side of the insert along the facing. The insert must be in place with the gas line and vent attached prior to installing the panels.
P AGE 12 I NSERT I NSTALLATION (C ONT .) - For qualified installers only! Gas Line Install ! The gas line must be installed in accordance with all local codes, if any; if not, follow ANSI Z223.
I NSERT I NSTALLATION (C ONT .) - For qualified installers only! P AGE 13 Vent Requirements ! Always maintain the required 1" clearance to combustible materials to prevent a fire hazard.
P AGE 14 F INALIZING THE I NSTALLATION ! Turn the gas control valve to "OFF" prior to conducting any service. 1 Remove the door. Unscrew and remove the door handle. NOTE : When re-installing, make sure the handle points away from the glass when finished.
F INALIZING THE I NSTALLATION (C ONT .) P AGE 15 3 Replace the door (follow step # 1 in reverse order). 4 Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot. Start the main burner. Leak test all gas joints again.
P AGE 16 O PERATING Y OUR H EATER Before You Begin ! Read this entire manual before you use your new heater (especially the section "Safet y Precautions" on pages 2 & 3). Failure to follow the instructions may result in property damage, bodily injury, or even death.
O PERATING Y OUR H EATER (C ONTINUED ) P AGE 17 Starting The Pilot Flame The pilot flame is required to ignite the main burners (it also plays a safety role). It should be left on once lit. It will stay lit unless the gas control valve is turned to "OFF".
P AGE 18 O PERATING Y OUR H EATER (C ONTINUED ) Starting the Heater for the First Time ¥ Painted Stoves require the paint to be cured. Start the heater and burn on low for 20 minutes.
O PERATING Y OUR H EATER (C ONTINUED ) P AGE 19 Adjusting the Blower Speed + The blower helps transfer the heat from the heater into the room. It will not turn on until the heater is up to temperature (approximately 10 minutes after starting). See the illustration below for instructions on adjusting the blower speed.
P AGE 20 M AINTAINING Y OUR H EATER Maintaining Your Stove's Appearance ! The optional brass door may be cleaned with a non-abrasive polish (such as Flitz¨).
T ROUBLESHOOTING P AGE 21 Problem: Possible Cause: Don't Call for Service Until You: Pilot Will Not Light A gas shut off valve is turned off The valve control knob isn't turned to "PILO.
P AGE 22 T ROUBLESHOOTING (C ONTINUED ) How this Heater Works ! This heater was designed with safety as the primary concern. Many of the components inside this heater are for safety purposes. Therefore, only certified gas service technicians should service this heater.
T ROUBLESHOOTING (C ONTINUED ) P AGE 23 Why Nothing Should Be Placed Against the Heater Your heater has a grill on the sides and top that must not be blocked. The area around the control cover allows air into the firebox. If it is blocked the combustion inside the firebox will not burn normally.
P AGE 24 W ARRANTY To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 10850 117th Place N.E., Kirkland, Washington 98033.
L ISTING I NFORMATION P AGE 25 The safety label can be found on the rear panel. A copy is shown below. Listed Gas-Fired Vented Room Heater Tested to ANSI Z21.
P AGE 26 O PTIONAL E QUIPMENT Stove Leg Installation (Brass # 99200500, Cast Black # 99200800, Black Steel # 99200100) Raise the stove 8" (use lumber or other sturdy device).
O PTIONAL E QUIPMENT (C ONTINUED ) P AGE 27 Surround Panel Installation + The surround panels come in the size s listed below PANEL SIZE HEIGHT WIDTH PART # 8" 28" 40" 99300259 10".
P AGE 28 O PTIONAL E QUIPMENT (C ONTINUED ) Thermostat (Part # 99300650) ! Do not connect 120 VAC to the gas control valve or wiring of this unit. 1 Route the thermostat wire through the rear panel (run it through one of the ventilation holes) and attach to the on/off switch (see the illustration below).
O PTIONAL E QUIPMENT (C ONTINUED ) P AGE 29 Remote Thermostat ! Do not connect 110-120 VAC to the gas control valve or wiring system of this unit. ¥ Follow the instructions included with the remote thermostat for installation.
P AGE 30 O PTIONAL E QUIPMENT (C ONTINUED ) Propane Conversion Kit (Part # 98900746) The propane conversion kit should be installed prior to installing the heater (if not, shut off gas and disconnect the heater from the gas line).
O PTIONAL E QUIPMENT (C ONTINUED ) P AGE 31 3 Remove the burner pan from the burner pan box following the instructions below. Slide the burner pan to the left until the fixed shutter disengages from the orifice. Place the burner pan aside. Burner Pan Burner Pan Box Fixed shutter Orifice c Remove the two screws holding the burner box front in place.
P AGE 32 O PTIONAL E QUIPMENT (C ONTINUED ) 4 Follow the directions below to remove the natural gas orifice. Apply thread sealant to the LP orifice (#49 - it has "49" stamped on it) and tighten in place with a 1/2" open end wrench. Replace the spring.
O PTIONAL E QUIPMENT (C ONTINUED ) P AGE 33 7 Replace the pilot assembly (follow the instructions in step 6 in reverse order). Make sure the pilot assembly gasket is placed correctly. 8 Replace the rear log shelf (see step 2). Install the logs and embers.
P AGE 34 I NDEX 151002 B Vent (insert) ....................................................1 3 B vent (stove) .....................................................8 Blower Speed .....................................................1 9 BTU Input ......
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Avalon Stoves 700 B-VENT è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Avalon Stoves 700 B-VENT - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Avalon Stoves 700 B-VENT imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Avalon Stoves 700 B-VENT ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Avalon Stoves 700 B-VENT, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Avalon Stoves 700 B-VENT.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Avalon Stoves 700 B-VENT. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Avalon Stoves 700 B-VENT insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.