Manuale d’uso / di manutenzione del prodotto Astoria Pellet Stove Astoria PS del fabbricante Avalon
Vai alla pagina of 42
Astoria Pellet Stove • Horizontal Or Vertical Vent • Freestanding Stove • Mobile Home Approved • Class A Chimney Retrofit • Hearth Stove into Existing Masonry Chimney , Masonry Fireplace, or Z.C. Fireplace - - Please read this entire manual before installation and use of this pellet fuel- burning room heater.
2 Introduction Travis Industries Heritage PS 270603 Introduction We welcome you as a new owner of an Astoria pellet heater. In purchasing an Astoria you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics.
Table of Contents 3 Travis Industries 4050225 100-01154 Introduction Introduction ......................................................2 Important Information .........................................2 Safety Precautions Safety Precautions ..........
4 Safety Precautions Travis Industries 4050225 100-01154 • Do not operate the heater if you smell smoke coming from the heater. Turn the M ODE switch to "OFF", monitor your heater, and call your dealer.
Safety Precautions 5 Travis Industries 4050225 100-01154 • The heater will not operate during a power outage. If a power outage does occur, check the heater for smoke spillage and open a window if any smoke spills into the room. • This heater must be connected to a standard 115 V.
6 Specifications Travis Industries 4050225 100-01154 Heating Specifications: Approximate Maximum Heating Capacity (in square feet)* ................................. 800 to 2,250 Sq. Feet Burn Rate (Pounds per Hour)** .................................
Installation 7 Travis Industries 4050225 100-01154 Before You Begin READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
8 Installation Travis Industries 4050225 100-01154 Clearances - Straight Installation 6 ” Minimum 3 ” Minimum 9 ” Minimum 3 ” Minimum Through the Wall Installations Interior Vertical Vents Flo.
Installation 9 Travis Industries 4050225 100-01154 Venting the Pellet Stove • PELLET VENT MUST MAINTAIN A MINIMUM 3" CLEARANCE TO ANY COMBUSTIBLE (INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER). • DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE.
10 Installation Travis Industries 4050225 100-01154 Pellet Vent Type • Must be 4" diameter Type "L"(except for masonry fireplace installations) - or - connect the vent to a factory built type "A" chimney. All vent joints (including adapters, elbows, etc … ) must be sealed with 500 ° F.
Installation 11 Travis Industries 4050225 100-01154 Mobile Home Requirements • Outside air is required (used for combustion) - see the directions below. • The heater must be bolted to the floor (Some states do not require this; check with your local building department).
12 Installation Travis Industries 4050225 100-01154 Alcove Installation Requirements When the pellet stove is placed in a location where the ceiling height is less than 7' tall, it is considered an alcove installation. Because of the reduced height, the requirements listed below must be met.
Installation 13 Travis Industries 4050225 100-01154 Installation Example: Direct "Through-the-wall" Installation 3 ” Minimum 9 ” Minimum Floor Protection 6 ” Minimum 12 ” Minimum Hor.
14 Installation Travis Industries 4050225 100-01154 Installation Example: Interior Vertical Installation Type "L" Vent 6 ” Minimum 3 ” Minimum Floor Protection 2 ” Minimum 9 ” Minimum Outside Air (optional) Floor Protection 24 ” Minimum Insulation must maintain 3 ” clearance.
Installation 15 Travis Industries 4050225 100-01154 Installation Example: Class A Chimney Retrofit Type "L" Vent 6 ” Minimum 3 ” Minimum Floor Protection 2 ” Minimum 9 ” Minimum Outside Air (optional) Floor Protection Outside air may be drawn from a ventilated crawl space.
16 Installation Travis Industries 4050225 100-01154 Installation Example: Masonry Fireplace Hearth Stove Outside air may be drawn from the ash cleanout. 6 ” Min. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone.
Installation 17 Travis Industries 4050225 100-01154 Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove “ L ” Vent Flex Section 6 ” Min. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone.
18 Installation Travis Industries 4050225 100-01154 Installation Example: Freestanding Masonry Chimney “ L ” Vent Sections 6 ” Min. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone.
Operation 19 Travis Industries 4050225 100-01154 Safety Notice Read this entire manual (especially the "Safety Precautions" on pages 4 and 5) before using this stove. Failure to follow the instructions may result in property damage, bodily injury, or even death.
20 Operation Travis Industries 4050225 100-01154 Loading Pellets Lift the hopper lid to its vertical position. Pour pellets into the hopper until full. NOTE: The hopper holds approximately 115 pounds of pellets. Make sure pellets are not left on this heat shield.
Operation 21 Travis Industries 4050225 100-01154 Manual Mode Manual mode requires the user to turn the heater on and off manually. To Start Press the "Manual Start" button. That's it. The stove automatically goes to a medium burn rate and high fan while the igniter starts the fire burning within 10 minutes.
22 Operation Travis Industries 4050225 100-01154 Auto Mode Auto mode allows you to use a thermostat to control room temperature. The stove automatically turns on when the temperature drops below the thermostat setting. Once the stove reaches operating temperature, the stove then runs at the heat output setting selected.
Operation 23 Travis Industries 4050225 100-01154 Restrictor Adjustment The exhaust restrictor “ fine tunes ” your appliance, adjusting the amount of air flowing to the flame. NOTE : the optimal restrictor position will vary over time as soot builds up inside the exhaust system.
24 Operation Travis Industries 4050225 100-01154 Start-Up Sequence This stove utilizes a start-up sequence whenever the mode switch is changed or the heater is started when cold. This is to ensure proper operation through all possible settings and operational states (hot or cold, pellets burning or not burning, etc.
Maintenance 25 Travis Industries 4050225 100-01154 Daily Maintenance (whenever using the stove) Inspect the Burn When burning on high, the flames should be bright orange with embers jumping from the firepot. NOTE : the optimal restrictor position will vary over time as soot builds up inside the exhaust system.
26 Maintenance Travis Industries 4050225 100-01154 Daily Maintenance (whenever using the stove) - Continued Check Firepot for Clinkers If the flames seem to be coming only from the sides, or are orange/black, turn the heater off and check for clinkers.
Maintenance 27 Travis Industries 4050225 100-01154 Door Opening WARNING : Make sure the heater has fully cooled (approximately 25 minutes) before opening the door. When securing the door, make sure the pawl fits over the bracket before tightening. NOTE : Do not overtighten the pawl.
28 Maintenance Travis Industries 4050225 100-01154 Bi-Weekly Maintenance (or every 10 bags of pellets) Clean the Heat Exchange Tubes Heat Exchanger Cleaning Rod Keep the door closed so the flyash does not enter the room. WARNING: The front edge of the hopper lid becomes very hot, do not touch the area below the handle.
Maintenance 29 Travis Industries 4050225 100-01154 Bi-Weekly Maintenance (or every 10 bags of pellets) - Continued Clean the Baffles Use both hands to lift each baffle up and forward. Then tilt the baffle downward to remove any flyash that may have accumulated on top of the baffle.
30 Maintenance Travis Industries 4050225 100-01154 Sweep Ash Into Ashpan HINT: The more often you clean out the flyash, the more efficient your heater will burn. Swing the side ash trap door up. Lift it up and away from the firebox. Repeat for the opposite side.
Maintenance 31 Travis Industries 4050225 100-01154 Bi-Weekly Maintenance (or every 10 bags of pellets) - Continued Check Ashpan, Dispose if necessary NOTE : When replacing the ash pan make sure it is pushed all the way in. The ash pan has a built in handle to ease transportation of the ashes.
32 Maintenance Travis Industries 4050225 100-01154 Yearly Maintenance (or every two tons) WARNING: Disconnect the power cord prior to conducting service.
Maintenance 33 Travis Industries 4050225 100-01154 Yearly Maintenance (or every two tons) - Continued Clean the Exhaust Blower (make sure the stove is cool and unplugged) a Open the hopper lid and remove the screw holding the left door in place. Remove the knob on the restrictor rod.
34 Maintenance Travis Industries 4050225 100-01154 Yearly Maintenance (or every two tons) - Continued Door Seal ! Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive sooting, inefficient burning, and perhaps a malfunction.
Maintenance 35 Travis Industries 4050225 100-01154 Adjusting the Door Hinge and Latch • The door hinge and door latches may be adjusted to pull the door closer to the body. The illustration below details how to adjust these components. NOTE: Make sure to read the section "Door Alignment" on the previous page before adjusting the door.
36 Maintenance Travis Industries 4050225 100-01154 Check for Air Leaks Around the Door, Glass, and Ashpan ! Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive sooting, inefficient burning, and perhaps a malfunction.
Normal Operating Sounds 37 Travis Industries 4050225 100-01154 Auger Motor When feeding pellets, you may hear the intermittent buzz of this motor running. Heat Exchanger Tubes You may hear the heated air being forced through these tubes by the convection fan.
38 Safety Label Travis Industries 4050225 100-01154 W ARNING - DO NOT REMOVE OR COVER THIS LABEL Listed Pelletized Solid Fuel Burning Appliance Also for Use in Mobile Homes Model: Astoria PS Serial No: T ested to: ASTM E, 1509-95, Room Heater Pellet Burning T ype (UM) 84 HUD Electrical Rating: 1 15V , 60Hz, 3 Amp; Start 3 Amps, Run 1.
Limited 7 Year Warranty 39 Travis Industries 4050225 100-01154 To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd.
40 Optional Equipment Travis Industries 4050225 100-01154 Thermostat (Part # 99300650) ! Do not connect 120 VAC to the thermostat circuit of this heater (do not use a household thermostat used for a wall-board or other electical heater). 1 Attach the thermostat wire to the circuit board (see the illustration to the right).
Optional Equipment 41 Travis Industries 4050225 100-01154 Remote Thermostat Follow the instructions included with the remote thermostat for installation. Using the Remote Thermostat The remote thermostat has a 1 to 2 minute lag time between the time the thermostat is turned up and the heater turns on.
42 Index Travis Industries 4050225 100-01154 Adjusting the Fan Speed ......................................2 3 Air Leaks ..........................................................3 6 Alcove Installation Requirements ..........................1 2 Ashpan (Opening and Disposing Ashes) .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Avalon Astoria Avalon Pellet Stove Astoria PS è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Avalon Astoria Avalon Pellet Stove Astoria PS - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Avalon Astoria Avalon Pellet Stove Astoria PS imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Avalon Astoria Avalon Pellet Stove Astoria PS ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Avalon Astoria Avalon Pellet Stove Astoria PS, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Avalon Astoria Avalon Pellet Stove Astoria PS.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Avalon Astoria Avalon Pellet Stove Astoria PS. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Avalon Astoria Avalon Pellet Stove Astoria PS insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.