Manuale d’uso / di manutenzione del prodotto 2190 del fabbricante Samson
Vai alla pagina of 37
The Samson RFX is d esigned to control and monitor the co nsumption and inventory b alances of a utomotive fluid p roducts with minima l installation and programm ing costs. The wall mounted keypad module consists of a 12-button keypad, LCD display and integral ticket printer.
Table of Contents Diagram of RF X Logical Set-up ....... ...................................................................................3 Keyboard Description ........................................................................................
PICTORAL DIAGRAM OF RF X LOGICAL SET-UP Samson Corporation-Swannanoa, NC 28778 800.311.1047 www.samsoncorporation.com.
Keyboard Description: FCC ID: GIF-RFKEYPAD FCC CERTIFIED, PART 15, SUBPART C This device complies with Part 15 of the FCC Rules. Operation is subject to the following two condi tions: (1) this device .
Default Screens: • The Personal Identification Number (PIN) number is 4 num eric digits • 1 supervisor account • Maximum of 50 operators • The supervisor account has access to the management s.
Management Menu: The management menu displays after entering the supervisor PIN Number Select INI CNF MET REP 190 - - - - - - - - - Active keys: , , Action: • Choose which menu option is desired Screens in INI can be accessed only when the Dispense Order list is empty.
Initialization Menu: Flow Chart a The parameter changes will affect all data in m emory (exam ple: if we change the quantity unit from liters to gallons, the general quantity will be simply switched f.
Initialization Menu Screens (INI): • System date and time are initially blank • System time is in m ilitary standard • System date is in format DD/MMM/YYYY (in English) • To change month, pres.
Tank Initialization: The tank screens are used to set up the tanks in the system. Each tank is assigned a number and a starting quantity level in the desired unit of measure.
Tank Stock Level No X: --------- Active keys: Numeric keys, , , Use the numeric keys to enter a stock level from 00000.000 to 99999.999. Press to move to next screen. Alphanumeric keys are validated only for some of the display m enus. In these menus to enter a letter just hold the related key and the letters scroll.
Tank-Fluid Relationship Screens: The relationship between tank id and fluid type id will be 1:1 (one tank assigned to one fluid type id). For example, the supervisor may associate tank #1 with fluid #1 or tank #1 with fluid #2. Each tank must be associated with one and only one fluid type.
Adding and Deleting RF Meters: (Meter and Hose are synonymous) This set of screens allows the Supervisor to add or delete RF Meters from the keypad system. • The RF Meter identification number can be found on the RF Meter under the battery pack • The RF Meter identification number format is 10 decim al digits (-.
No Action The relationship between tank and RF Meter will be 1:n (one tank assigned to n meters). Since there will be a relationship between tank and fluid type, the RF Meter will be assigned to one fluid type. Assign the RF Meter to the tank in which it is connected.
Adding and Deleting Operators: • Only an operator with valid PIN can dispense fluid • A Maximum of 50 operators m ay be active in the system at a time • The operator id (PIN number) format is 4 .
Samson Corporation-Swannanoa, NC 28778 800.311.1047 www.samsoncorporation.com.
Configuration Menu: (CNF) The Configuration Menu allows the supervisor to set-up all parameters for the Keypad Operation. The Supervisor is the only user with access to these screens.
System Reset: Allows the user to reset all the configuration parameters to default values: System Reset YES / NO Active keys: , , Action: • If yes, the keypad asks the user to confirm • If no, the.
Mileage and Registration Information Option: Allows the supervisor to select the storage of vehicle mileage and registration information for each dispense order.
Keypad Timeout Option: • Timeout parameter corresponding to the tim e it takes to validate after all dispense order data has been entered. If the enter button is not pressed within the time allocated, the keypad display goes back to the initial menu, and the input data is erased.
Display Timeout Option: (Do Not Change) • Timeout parameter corresponding to the tim e for displaying information on the keypad LCD before it is refreshed with new information • The display timeou.
Action: • Use scroll key to select the external printer setting • Press Enter key to move to select the external printer setting and Supervisor Password Option Supervisor Password Option: The default supervisor password for protecting the modification of the supervisor id is 0000.
Action: Select YES or NO by using the scroll key, then press Enter. The keypad will display the Supervisor Menu . Meter Reset Menu (MET): • Only the supervisor has access to this process. • The supervisor may delete a dispen se order in the keypad que for a single hose or all hoses in the system.
Report Menu Screens: (REP) The supervisor has the opportunity to print out a variety of reports, if there is an external printer connected to the keypad.
Initialization Report: DD/MMM/YYYY INITIALIZATION REPORT HH:MI TNK PRODUCT LEVEL UNT === ================ ===== ====== 1 Fluid 1 name 99999 LITERS 2 Fluid 2 name 99999 LITERS (…) (…) (…) (…) 7.
Configuration Report: DD/MMM/YYYY CONFIGURATION REPORT HH:MI Mileage Type K M Registration Info NO Mileage Info NO Internal printer Yes External printer Yes Address printer Buzzer Yes Approved PTB N O.
Communications Report: DD/MMM/YYYY COMMUNICATION REPORT HH:MI ADDR ID STA ====== ==== === 0.000.000.101 1 inactive 0.000.000.137 2 inactive 0.000.000.111 3 inactive 0.000.000.126 4 inactive 0.000.000.127 5 inactive 0.000.000.109 6 inactive 0.000.000.100 7 inactive 0.
Dispense Order Reports: Select Report INI CNF COM WO Active keys: , , Action: • Scroll to WO and press Enter key • Enter key with no entry Æ Supervisor Menu screen is displayed Select REP USR PRO.
Product Report (PRO): DD/MMM/YYYY STATISTICAL REPORT BY PRODUCT HH:MI PRODUCT USER QTY ================ ================ ===== FLUID TYPE 1 JOHN SMITH 99999 PAUL GREEN 99999 FLUID TYPE 2 JOHN SMITH 99.
Tank Report (TNK): DD/MMM/YYYY STATISTICAL REPORT TANK LEVEL HH:MI TNK PRODUCT LEVEL UNT === ================ ===== ======= 1 5W30 OIL 123 LITERS 2 GEAR OIL 1111 LITERS 3 ATF 111 11111 GALLONS 4 HYDRA.
Internal Printer Reports: FLU: Prints all fluids created in the system HDS: Prints all hose numbers with meter serial num bers TNK: Prints all tanks created in the system USE: Prints all operators cre.
Fluid Type Definitions Fluid id Name 1 2 3 4 5 6 7 8 Maximum Fluid types is 8 The Fluid name can be 16 characters in length Samson Corporation-Swannanoa, NC 28778 800.
Tank Definitions Tank id Tank Level Tank Capacity 1 2 3 4 5 6 7 8 Maximum of 8 Tanks The Tank Capacity value is formatted 00000.000 Samson Corporation-Swannanoa, NC 28778 800.
Hose/Meter Definitions Hose/Meter id Address Number x.xxx.xxx.xxx 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Maximum of 48 Hose/Meters Hose/Meters address is a 10 digit number Address Data Format is x.xxx. xxx. xxx Samson Corporation-Swannanoa, NC 28778 800.
Hose/Meter Definitions Hose/Meter id Address Number x.xxx.xxx.xxx 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Maximum of 48 Hose/Meters Hose/Meters address is a 10 digit number Address Data Format is x.xxx. xxx. xxx Samson Corporation-Swannanoa, NC 28778 800.
User Definitions User id User Name Pin id 1 Reserved Supervisor 0000 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 The User Name is up to 16 characters The User Pin id is a 4 digit number with leading 0’s required Samson Corporation-Swannanoa, NC 28778 800.
User Definitions User id User Name Pin id 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 The User Name is up to 16 characters The User Pin id is a 4 digit number with leading 0’s required Maximum of 50 users Samson Corporation-Swannanoa, NC 28778 800.
Samson Corporation-Swannanoa, NC 28778 800.311.1047 www.samsoncorporation.com.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Samson 2190 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Samson 2190 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Samson 2190 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Samson 2190 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Samson 2190, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Samson 2190.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Samson 2190. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Samson 2190 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.