RuggedCom Inc. I 30 W hitmore Road, W oodbr idge, Ontario, C anada L4L 7Z4 Tel: (905) 856-528 8 I Fax: (905) 8 56-1995 I Toll Free: (888) 264-0006 Rugg ed Rugg ed Rugg ed Rugg edWir eless Wirele ss Wirele ss Wirele ss R R R R S S S S 900 900 900 900 W W W W Family Famil y Famil y Famil y Installatio n Guide www.
2 2008 Rugge dCom Inc . All rights reserv ed Rev103 Federal Communications Commission Radio Frequency Interference Statement This equipmen t has been tested and found to comply with the limits for a Class A digital device pursuant to Part 1 5 of the FCC Rules.
3 2008 Rugge dCom Inc . All rights reserv ed Rev103 Table of Contents 1 Product Overview .................................................................................................................. 4 1.1 Functional Overview .................
4 2008 Rugge dCom Inc . All rights reserv ed Rev103 1 Product Overview 1.1 Functional Overview The RuggedWireless RS9 00W family of products are indu strially hardened, fully managed, IEEE 802.
5 2008 Rugge dCom Inc . All rights reserv ed Rev103 1.3 RS900W Family Front Panel View Figure 1 - Front Panel Des cription ITEM Activity Comments Solid Link Established LINK LED (Yello w) Blinking.
6 2008 Rugge dCom Inc . All rights reserv ed Rev103 1.4 RS900W Family Bottom Panel View Figure 2 - Bottom Pan el Description Chassis ground Power Supply Connection Optional DIN Rai l Mounting Brac.
7 2008 Rugge dCom Inc . All rights reserv ed Rev103 2 Inst al lation 2.1 DIN Rail Mounting An optional DIN ra il mounting bracket is available for the RS90 0W.
8 2008 Rugge dCom Inc . All rights reserv ed Rev103 2.2 Power Supply Wiring and Ground ing 2.2.1 AC Pow er Suppl y Wiring and Gro unding Figure 4 - Power Supply Inp uts The AC powe r supply inputs should be connected as foll ows: 1. +/L should be connected to AC Line/Hot.
9 2008 Rugge dCom Inc . All rights reserv ed Rev103 2.2.2 DC Pow er Suppl y Wiring and Gro unding Figure 5 - DC Power supply wi ring and grounding di agram The low vo ltage DC power supply features reve rse polarity protection and dual indep endent inputs.
10 2008 Rugge dCom Inc . All rights reserv ed Rev103 2.3 Dielectric Strength (HIPOT) Testing Units which a re to have dielectric strength testing (HIPOT te sting) done in the field must ha ve the braided ground cable disconnected during the test.
11 2008 Rugge dCom Inc . All rights reserv ed Rev103 2.4 Failsafe Output Wiring and Specific ations The Failsafe output relay is provided to signal critical error conditions that may occur on the unit. The contact s are energized upon power up of the un it and remain energized until an alarm condition or powe r loss occurs.
12 2008 Rugge dCom Inc . All rights reserv ed Rev103 2.5 RS232 Port Wiring The RS232 po rt is used for configuring the unit. A stra ight-through serial cable with a DB-9 connector is re quired. There is no need to crossover the Transmit and Receive signals f rom the PC side since this has been done internally as is shown below.
13 2008 Rugge dCom Inc . All rights reserv ed Rev103 2.6 RJ45 Ports – Signal Description Units with 10/100 Base-TX ports allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) ca ble with RJ45 male conne ctors.
14 2008 Rugge dCom Inc . All rights reserv ed Rev103 3 T echnical Speci fications 3.1 Operating Environment Parameter Range Commen ts Ambient Operat ing Temperatu re -40 to 85 ° C Ambient Temp erature as me asured from a 30 cm radius surrounding the center of th e enclosure.
15 2008 Rugge dCom Inc . All rights reserv ed Rev103 Isolation Comments 1500 V rms Dielectric test vo ltage (1 minute) between coil & contacts Table 7 - Failsafe Rela y Isolation 3.
16 2008 Rugge dCom Inc . All rights reserv ed Rev103 3.5 Wireless Standards Supported Standard Parameter Mode Notes IEEE 802.11g 54 Mbps (WLAN) Full Access Point 2.4 Ghz ISM IEEE 802.11b 11 Mbps (WLAN) Client support Backwards compat ibility IEEE 802.
17 2008 Rugge dCom Inc . All rights reserv ed Rev103 3.7 IEEE 802.11b/g The channe l identifiers, channel c enter freq uencies, and regu latory domains of e ach IEEE 802.
18 2008 Rugge dCom Inc . All rights reserv ed Rev103 3.8 Fiber Optical Port Specifications Order Code Speed Standard Mode / Connect or Tx (nm) Cable Type (um) Tx min (dBm) Tx max (dBm) Rx Sensitivity (dBm) Rx Saturation (dBm) Typical Distance (km) Power Budget (dB) MJ 100FX MM/MT RJ 1300 50/125 -22.
19 2008 Rugge dCom Inc . All rights reserv ed Rev103 3.9 Physical Dimensions Figure 10 - Mechanica l Specifications.
20 2008 Rugge dCom Inc . All rights reserv ed Rev103 3.10 Agency Approvals Agency Standards Commen ts CSA CSA C22.2 No. 60 950, UL 6095 0 Approved CE EN 60950, EN 61000-6-2 CE Compliance is claime.
21 2008 Rugge dCom Inc . All rights reserv ed Rev103 5 Appendix A - Rugge dWireless ™ Fre quentl y Asked Questions ( F A Q) What factors c an affect wireless coverage/range? Range e stimates are typ ical a nd require line of sight.
22 2008 Rugge dCom Inc . All rights reserv ed Rev103 dBm Watts dBm Watts dBm Watts 0 1.0 mW 16 40 mW 32 1.6 W 1 1.3 mW 17 50 mW 33 2.0 W 2 1.6 mW 18 63 mW 34 2.5 W 3 2.0 mW 19 79 mW 35 3.2 W 4 2.5 mW 20 100 mW 3 6 4.0 W 5 3.2 mW 21 126 mW 3 7 5.0 W 6 4 mW 2 2 158 mW 38 6.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il RuggedCom RS900W è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del RuggedCom RS900W - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso RuggedCom RS900W imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul RuggedCom RS900W ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il RuggedCom RS900W, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del RuggedCom RS900W.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il RuggedCom RS900W. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo RuggedCom RS900W insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.