Manuale d’uso / di manutenzione del prodotto OL50145MW del fabbricante RIDGID
Vai alla pagina of 20
1 Y our air compressor has been engineer ed and manufactured to our high standar d for dependability , ease of operation, and operator safety . When properly car ed for , it will give you years of rugged, trouble-fr ee performance.
2 Introduction....................................................................................................................................................................... 2 General Safety Rules ................................
3 GENERAL SAFETY RULES WARNING: Read and understand all instructions. Failure to follow all instructions listed below may r esult in electric shock, fir e, and/or serious personal injury . SA VE THESE INSTRUCTIONS WORK AREA Keep your work area clean and well lit.
4 Kno w your po wer to ol. Re ad oper ato r’ s ma nua l car efu lly . Learn its applications and limitations, as well as the specific potential hazar ds related to this tool. Following this rule will reduce the risk of electric shock, fire, or serious injury .
5 SYMBOLS Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper inter - pretation of these symbols will allow you to operate the pr oduct better and safer .
6 SYMBOLS SERVICE Servicing requires extr eme care and knowledge and should be performed only by a qualified service technician. For service we suggest you return the product to your near est AUTHORIZED SERVICE CENTER for repair . When servic- ing, use only identical replacement parts.
7 EXTENSION CORDS Use only 3-wire extension cords that have 3-prong ground- ing plugs and 3-pole r eceptacles that accept the product’ s plug. When using a power tool at a considerable distance fr om the power sour ce, use an extensio n cor d he avy en ough to carry the current that the tool will draw .
8 GLOSSAR Y OF TERMS Pressur e Regulator Knob Regulates the outgoing pressure from the air outlet to the tool. It is possible to increase or decrease the pressure at the outlet by adjusting this control knob. Pressur e Switch Automatically controls the on/off cycling of the compressor .
9 0 0 2 4 50 100 150 230 200 bar 100 0 0 16 5 50 150 200 230 bar psi ON OFF O I 1 TM 2 MINI WHEELBARROW COMPRESSOR OIL LUBE PUMP - POMPE A HULE - BOMBA CON LUBRICACION DE ACI ETE 5 Gallon 18,8 Litre 18,7 Litro 4.
10 0 2 4 6 40 80 120 160 bar 0 2 4 6 40 80 120 160 bar ON OFF O I 1 TM 2 MINI WHEELBARROW COMPRESSOR OIL LUBE PUMP - POMPE A HULE - BOMBA CON LUBRICACION DE ACI ETE 5 Gallon 18,8 Litre 18,7 Litro 4.
11 ASSEMBL Y INST ALLING THE DIPSTICK See Figure 4. The air compressor has a label installed between the oil fill hole and a travel cap. Before using the unit the first time, remove travel cap and label and insert supplied dipstick. Make sure to add oil befor e first use.
12 ON OFF O I ON 0 2 4 6 40 80 120 160 bar 0 2 4 6 40 80 120 160 bar 1 TM 2 MINI WHEELBARROW COMPRESSOR OIL LUBE PUMP - POMPE A HULE - BOMBA CON LUBRICACION DE AC IETE OPERA TION DANGER: Do not disasse mble check valve, tank drain valves or safety relief valve with air in tank — bleed tanks.
13 0 0 2 4 50 100 150 230 200 bar 100 0 0 16 5 50 150 200 230 bar psi TM 2 MINI WHEELBARROW COMPRESSOR OIL LUBE PUMP - POMPE A HULE - BOMBA CON LUBRICACION DE AC IETE Attach 1/4 in. NPT male connector fitting to accessory or tool you intend to use.
14 CHECKING THE SAFETY V AL VE See Figure 12. DANGER: Do not attempt to tamper with the safety valve. Anything loosened from this device could fly up and hit you. Failur e to heed this warning could result in death or serious personal injury . The safety valve will automatically release air if the air tank pressur e exceeds the preset maximum.
15 ON OFF O I ON MAINTENANCE WARNING: When servicing use only identical RIDGID ® replacement parts. Use of any other parts may create a hazar d or cause product damage. WARNING: Always wear safety goggles or safety glasses with side shields during power tool operation or when blowing dust.
16 ON OFF O I ON MAINTENANCE Fig. 15 DRAIN PLUG OIL FILL HOLE COLLECT USED OIL IN A SUIT ABLE CONT AINER CHANGING THE OIL See Figure 15. Replace the oil after the first 100 hours of operation and every 100 hours following the first oil change. Place a suitable container underneath the drain to collect used oil.
17 TROUBLESHOOTING PROBLEM CAUSE SOLUTION Compressor will not run Loss of power or overheating No electrical power Blown shop/house fuse Shop/house breaker open Thermal overload open Pressur e switch .
18 Proof of purchase must be presented when requesting war - ranty service. This product is manufactured by One W orld T echnologies, Inc. The tra demark is lice nsed from RIDGID, Inc. Al l warra nty commu nication s shoul d be directe d to One W orld T echnolo- gie s, Inc.
19 NOTES.
20 Customer Service Information: For parts or service, contact your near est RIDGID ® authorized service center . Be sure to provide all relevant information when you call or visit. For the location of the authorized service center nearest you, please call 1-800-4-RIDGID or visit us online at www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il RIDGID OL50145MW è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del RIDGID OL50145MW - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso RIDGID OL50145MW imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul RIDGID OL50145MW ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il RIDGID OL50145MW, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del RIDGID OL50145MW.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il RIDGID OL50145MW. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo RIDGID OL50145MW insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.