Manuale d’uso / di manutenzione del prodotto RPS II del fabbricante ResMed
Vai alla pagina of 16
Respiratory Care Solutions P o w er Station II BA TTERY P ACK User Guide English.
P o w er Station II BA TTERY P ACK / AKKUP ACK / BA TTERIE / ALIMENT A TORE A BA TTERIA / BA TERÍA / BA TERIA / ACCU / BA TTERIP ACK / BA TTERIP AKKE / BA TTERIP AKKE / AKKU / ΜΠΑ ΤΑΡΙΑ / 电.
3 2 1 4 D * 3 4 5 2 1 6 E * 1 2 3b 3a * * Example device illustration only / Abbildung eines Beispielgerätes / Exemple d’appar eil / Illustrazione dell’apparecchio a solo titolo di esempio / Ilus.
i P o w er Station II DC output v oltage & DC cables 24V 26V DC Cable Par t Number VP AP ™ III ST -A 24959 VP AP ™ III ST -A with Quic kNav 24959 VP AP ™ Auto 25 24960 VP AP ™ .
ii Svenska Obs! • Vissa utrustningar finns inte i alla delar a v världen. • För inf ormation om batteriernas körtider hän visas till Produktkompatibilitetslista för bat terier/ utrustningar på www .resmed.com. Dansk Bemærkninger: • Det er ikke alle apparater , der kan fås i alle lande.
English 1 Intended use The R esMed P ower Station II (RPS II) is an external lithium-ion bat ter y that provides pow er when mains pow er is unav ailable.
2 Set ting up CA UTION • Ensure the RPS II and the device are turned off before set ting up. • When the RPS II is plugged to the mains power supply , ensure all cables are properly connected.
English 3 2. Plug the bat ter y coupler cables into eac h of the bat ter y DC input/output ports. The bat ter y coupler cables are marked with ‘1’ (primar y) and ‘2’ (reser ve) labels. 3. a. When c harging t wo bat teries, at tach the po wer supply unit adapter to the DC plug and connect the adapter to the the bat ter y coupler .
4 Using humidifi ers When a device integrated with the HumidAire 2i ™ or H4i ™ humidifi er is not connected to the mains pow er supply , the humidifi er will only operate in passive unheated mode despite the warm-up message appearing on the de vice.
English 5 T r oubleshooting If there is a problem, tr y the follo wing suggestions. If the problem cannot be solved, contact your equipment supplier or ResMed. Do not at tempt to open the bat ter y . Problem/P ossible cause Solution Device is not running P ower connections are disr upted.
6 T ec hnical specifications Bat ter y tec hnology Lithium ion Capacity < 1 0 0 Wh (97 Wh) UN classification UN3481 (lithium-ion bat teries pack ed with equipment) P ower supply Input range 1 00–240V , 50–60Hz, 1 .0-1 .5A Nominal for aircraf t use 1 1 0V , 40 0Hz Bat ter y output voltage (24V / 26V) ± 0.
English 7 Symbols The f ollowing symbols ma y appear on the device or pac kaging: At tention, consult accompanying documents; Read instructions bef ore use; Drip proof; No protection; Class II equipme.
8 • Make sure to periodically recharge the bat tery due to effects of self- disc harging. • As the battery ages, the available capacity decreases. When the remaining battery capacity is get ting low, do not rely on the RPS II as the primary supply .
English 9 Limited w arr anty ResMed Ltd (hereafter ’ResMed’) warrants that your ResMed product shall be free from defects in material and workmanship from the date of purchase for the period specified below.
10 This w arranty gives y ou specific legal rights, and you ma y also hav e other rights whic h vary from region to region. For further inf ormation on your w arranty rights, contact your local R esMed dealer or ResMed of fice.
Global leaders in sleep and respiratory medicine www .resmed.com 248527/2 20 1 2-07 P ow er Station II USER ROW MUL TI Respiratory Care Solutions Manufacturer: ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia. Distributed by: ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il ResMed RPS II è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del ResMed RPS II - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso ResMed RPS II imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul ResMed RPS II ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il ResMed RPS II, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del ResMed RPS II.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il ResMed RPS II. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo ResMed RPS II insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.