H8S/2643 Series FP-144 User System Interface Cable (HS2643ECH61H) for E6000 Emulator User’s Manual HS2643ECH61HE(C).
Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document.
i Preface Thank you for purchasing this user system interface cable (HS2643ECH61H) for the Renesas’s original mi crocomputer H8S/2643 series. The HS2643ECH61H is a user system interface cable that c.
ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connecting User System Interf ace Cable to Em ulat or Station .
Section 1 Configuration CAUTION Use an NQPACK144SD socket (manufactured by Toky o Eletech Corporation) for the FP-144 package IC socket on the user system. Figure 1 shows the configuration of the HS2643E CH61H user system interface cable for the FP-144 package.
2 Table 1 lists t he HS2643ECH61H components. Please m ake sure you have all of these com ponents when unpacking. Table 1 HS2643ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Flat cab.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and w ill damage the user system and the emulator product or will result in PERSONAL INJURY.
Emulator station E6000 Cable body connector User system interface cable Figure 2 Connecting User System Int erface Cable to Emulator Station 4.
2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
IC socket (NQPACK144SD manufactured by Tokyo Eletech Corporation) User system Guide pins 4 projections to apply epoxy resin adhesive to Bottom view of IC soket Pin 1 Figure 3 Location Setting of IC Socket 2.2.2 Soldering IC Socket After fastening, solder the IC socket for a FP-144 package to the user system.
7 2.2.4 Fastening Cable Head CAUTION 1. Use the screwdriver provided for tightening screw s. 2. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
Fasten the user system interface cab le head to the IC socket for a FP-144 package on the user system with the four screws (M2 x 10 mm) provided. Each screw shoul d be tightened a little at a tim e, alternating between screws on opposing corners.
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Cable head Remove jig Push the remove jig Removing User system Figure 5 Fastening Cable Body 9.
2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for a FP-144 package (NQPACK144SD: m anufactured by Tokyo Eletech Corporation).
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 7. Figure 7 Dimensions for User System Interface Cable Head 11.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 8.
13 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screw s.
MCU Pin 1 IC socket (NQPACK144SD manufactured by Tokyo Eletech Corporation) User system Screws (M2 x 6 mm) Socket cover Figure 9 Installing MCU to User System 14.
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2633 series, turn on the emulator according to the procedures described in the H8S Series E6000 Em ulator User's Manual (HS2000EPI61HE).
Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MCU.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Renesas FP-144 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Renesas FP-144 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Renesas FP-144 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Renesas FP-144 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Renesas FP-144, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Renesas FP-144.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Renesas FP-144. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Renesas FP-144 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.