Manuale d’uso / di manutenzione del prodotto U39-LP del fabbricante Regency
Vai alla pagina of 40
WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
2 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove REGENCY ULTIMATE Direct Vent Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art ULTIMATE Direct Vent Gas Stove by FPI Fireplace Products International Ltd.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 3 T ABLE OF CONTENTS Page Page System Data Chart ................................................................ 21 Gas Connection ...............................................................
4 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove This is a copy of the label that accompa- nies each ULTIMATE Direct Vent Free- standing Gas Stove. We have printed a copy of the contents here for your review. SAFETY LABEL The safety label is located on the inside of the drop down pedestal door.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 5 IMPORT ANT : SA VE THESE INSTRUCTIONS The ULTIMATE Direct Vent Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the in- structions in this manual first.
6 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove INST ALLA TION 8) Any safety glass removed for servicing must be replaced prior to operating the appliance. 9) To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 7 LOUVER INST ALLA TION 1) Attach the top & bottom louvers to the side stove panel using 2 screws per side. INST ALLA TION MANUF ACTURED MOBILE HOME ADDITIONAL REQUIREMENTS 1) Ensure that structural members are not cut or weakened during installation.
8 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove EXTERIOR VENT TERMINAL LOCA TIONS A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) C= Clearance to permanently closed window *(min.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 9 946-506/P Vent Guard (Optional) 640-530/P Riser Vent Terminal 946-205 Vinyl Siding Shield for Riser Vent Terminal 946-208/P Vent Guard (Option.
10 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations Alternate Horizontal Termination Caps INST ALLA TION The FPI AstroCap TM and F.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 11 Vent or Fireplace Products Interna- tional Ltd. 4) Installation other than as instructed by Simpson Dura-Vent and Fireplace Prod- ucts International Ltd. Warning: Always maintain re- quired clearances (air spaces) to nearby combustibles to pre- vent a fire hazard.
12 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove Horizontal Venting with Two (2) 90 o Elbows Option V H + H1 A) 3' Min. 2' Max. B) 5' Min. 3' Max. C) 8' Min. 4' Max. With these options, maximum total pipe length is 30 feet with minimum of 8 feet total vertical and maximum 4 feet total horizontal.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 13 INST ALLA TION DV ST OVE HORIZONT AL VENT KIT (# 946-1 16 & #946-216) INST ALLA TION Minimum Installation Height: U39: 59-3/4" ( 1518mm) DV ST OVE HORIZONT AL VENT KIT DV Stove Horizontal Vent Kit (2 ft.
14 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove INST ALLA TION Note: if the centerline cannot be met, the adjustable sections will have to be cut. e) Cut the 2 ft. or 4 ft. section of rigid pipe to length. Ensure that the pipe length when cut will seat onto both the start- er collar and the 90 o elbow.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 15 Alternate Horizontal Termination Caps Dura-Vent Basic Horizontal Kit # 970 1 90 o Elbow 1 Wall Thimble Cover 1 Horiz.
16 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove NOTE: For Snorkel terminations in ABOVE grade installations, follow national or lo- cal code requirements.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 17 Diagram 10 Diagram 9 Diagram 8 Diagram 7 Diagram 6 7) Install the Wall Thimble in the center of the 10" square and attach with wood screws. 8) Slide the decorative wall thimble up to the wall surface being careful not to scratch the paint and attach with screws provided.
18 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove INST ALLA TION Diagram 11: The upper half of the flashing is installed under the roofing material and not nailed down until the chimney is installed.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 19 INST ALLA TION Using a level, make sure the support is vertical. If the support extends above the roof, cut it flush with the top of the roof. Nail the support to the frame opening using (8) 3" spiral nails or #8 x 1-1/2" screws.
20 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove Converting a Masonry Chimney Important: The existing masonry flue opening needs to have an area of at least a 36 sq.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 21 U39-NG: For 0 to 2000 feet altitude U39-LP: For 0 to 4500 feet altitude Burner Inlet Orifice Sizes: Natural Gas Propane Burner #32 #50 Max. Input - Natural Gas/Propane 38,000 Btu/h Min. Input - Natural Gas/Propane 20,000 Btu/h Supply Pressure Natural Gas min.
22 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove INST ALLA TION Installer Notice: These instructions must be left with the appliance. Burner Orifice CONVERSION FROM NA TURAL GAS T O PROP ANE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit #730-969 Contains: Qty.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 23 INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
24 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove C)02-44 LOG SET INST ALLA TION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 25 INST ALLA TION Diagram 1 FRONT DOOR INST ALLA TION (packaged separately) 1) Open the two side panels. 2) Slide the door onto the two hinge pins mak- ing sure the two pieces are flush together.
26 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 14 GA. 16 GA. 18 GA. 20 GA. 22 GA. 50 Ft. 32 Ft. 20 Ft. 12 Ft. 9 Ft. Recommended Maximum Lead Length (Two-Wire) When Using Wall Thermostat (CP-2 System) Wire Size Max. Length Thermostat Wire Table OPTIONAL W ALL THERMOST A T A wall thermostat may be installed if desired.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 27 OPERA TING INSTRUCTIONS 8) Rotate the HEAT control to adjust the flame height higher or lower. SHUTDOWN INSTRUCTIONS 1) Use the Burner ON/OFF switch, thermo- stat or remote control to turn off the burner.
28 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove NORMAL OPERA TING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 29 MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year.
30 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove Mitred Glass Replacement Removing Glass 1) Remove the door from the unit and place on a soft surface to prevent scratching. 2) Pull out the door gasket. 3) Remove the 24 nuts holding the glass retainers in place.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 31 MAINTENANCE FAN MAINTENANCE If your fan requires maintenance or replace- ment, access to the fan is through the plate on the rear wall of the firebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and cor- rectly sealed.
32 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove REMOVING VAL VE 2) Undo the six screws holding the control panel in place. 3) Disconnect all wires from the back of the panel and then remove panel. You should lay the panel on a soft cloth so it doesn't get marked up.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 33 P ARTS LIST 30) 630-021 Fan Access Panel 31) 730-019 Rear Panel 32) 730-565 Firebox Baffle/Restrictor Assy 33) 630-520 False Top Assembly 36).
34 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove U39 BURNER & LOG ASSEMBL Y 51) 910-241 Burner ON/OFF Switch (3-way) 52) 910-190 Piezo Ignitor & Nut 53) 904-586 Knob for Fan Speed Co.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 35 PARTS LIST U39 DOOR ASSEMBLIES Part # Description 730-923 Brush Nickel Mitred Door - Complete 730-924 Gold Mitred Door - Complete 730-926 Bla.
36 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove _____________________________________________________________________________________ _______________________________________________________.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 37 _____________________________________________________________________________________ _______________________________________________________.
38 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove _____________________________________________________________________________________ _______________________________________________________.
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 39 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility.
Installer: Please complete the following information Dealer Name & Address: ________________________________________________ ______________________________________________________________________ .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Regency U39-LP è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Regency U39-LP - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Regency U39-LP imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Regency U39-LP ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Regency U39-LP, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Regency U39-LP.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Regency U39-LP. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Regency U39-LP insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.