Manuale d’uso / di manutenzione del prodotto P42-LP3 del fabbricante Regency
Vai alla pagina of 44
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 918-407 MODELS: P42-NG3 Natural Gas P42-LP3 Propane P42 Gas Fireplace WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Stove by FIREPLACE PRODUCTS INTERNATIONAL. The P42 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 3 T ABLE OF CONTENTS Brick Panels ............................................................. 2 3 Log Set Installation ................................................... 2 4 Flush Door ........
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 4 This is a copy of the label that accompanies each P42 Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the con- SAFETY LABEL tents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 5 INST ALLA TION IMPORT ANT : SA VE THESE INSTRUCTIONS The P42-NG /P42-LP D irect Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 6 Diagram 1 INST ALLA TION UNIT SPECIFICA TIONS This includes: 1) Clocking the appliance to ensure the cor- rect firing rate (rate noted on label 35,000 Btu/h) after burning appliance for 15 min- utes.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 7 MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram below: MANTELS Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from louver are shown in the diagram below.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 8 TOP ASSEMBL Y & NAILING STRIPS The Top Facing Support and Side Nailing Strips must be correctly positioned and attached be- fore the unit is slipped into position. 1) The top standoffs are shipped installed.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 9 EXTERIOR VENT TERMINA TION REQUIREMENTS INST ALLA TION . B B B B A C V V V V V V V A A V Fixed Fixed Openable Closed Closed Openable N L B E B .
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 10 INST ALLA TION VENTING Regency Direct Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the P42 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 11 RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 12 Rigid Pipe Adaptor (Part# 510-994) Pipe Length V ertical T erminal S torm Collar Part # 953 Flashing 943 or 943S Ceiling Firestop (Part # 963) 24" Pipe Length Adj.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 13 INST ALLA TION RIGID PIPE VENTING ARRANGEMENTS - HORIZONT AL TERMINA TIONS REGENCY DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) The shaded areas in the diagram show all allowable combinations of vertical runs with horizontal terminations.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 14 INST ALLA TION RIGID PIPE VENTING ARRANGEMENTS - HORIZONT AL TERMINA TIONS REGENCY DIRECT VENT SYSTEM (FLEX) - Propane & Natural Gas The diagram below shows examples of horizontal termination arrangements using two 90 o elbows.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 15 INST ALLA TION RIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINA TIONS (Propane & Natural Gas) Note: Must use optional rigid pipe adap- tor when using rigid pipe vent systems (Part # 510-994).
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 16 The P42 is approved for a 23 ft. (7.0m) vertical, with a maximum 12 ft (3.7m) horizontal offset using two 90 o elbows (two 45 o elbows equal one 90 o elbow) with rigid pipe vent systems for Propane and Natural Gas, as per the diagram below.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 17 Flex Liner Exhaust Flue A maximum of two certified joiner kits may be used per length. #948-305 (35 ft) Air Intake Co-linear DV V ertical T er.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 18 INST ALLA TION Venting Arrangements - Vertical Terminations with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 19 INST ALLA TION Below Grade Installation If the Snorkel Termination must be installed below grade, i.e. basement application, prop- er drainage must be provided to prevent water from entering the Snorkel Termination.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 20 6) Continue to assemble pipe lengths. Note: If an offset is necessary in the attic to avoid obstructions, it is impor- tant to support the vent pipe every 3 feet (0.9 meter), to avoid exces- sive stress on the elbows, and possible separation.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 21 INST ALLA TION termination and slipping the 4"(100mm) liner over it at least 1-3/8" (35mm).
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 22 GAS LINE INST ALLA TION The gas line can be brought through either the right or the left side of the appliance. The gas valve is situated on the right hand side of the unit and the gas inlet is on the right hand side of the valve.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 23 INST ALLA TION AERA TION ADJUSTMENT The aeration adjustment gears are located on the valve mounting plate and are accessed from underneath through the bottom louver opening.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 24 Burner tray without front logs in place All 3 logs in place PROP ANE LOG SET INST ALLA TION NA TURAL GAS IMPORTANT For Propane Units - only place rockwool on the rear burner tray behind the burner tube.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 25 INST ALLA TION Diagram 1 Diagram 3 ST ANDARD FLUSH DOOR The standard flush door comes with a black frame. To install the frame, simply hook the top door flange onto the top of the unit and swing the door towards the unit, diagram 1.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 26 BA Y LOUVERS 1) Install top louver by sliding the two bracket clips into the brackets located on top of the bay door. See below. The fitted louver leaves a small gap between faceplate bottom and louver top.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 27 INST ALLA TION FULL SCREEN FRONT 2) Remove the Screen Doors from the Full Screen Door Frame by fully opening the doors and lifting up off of the hinges.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 28 INST ALLA TION Inner Cut-Outs Bottom Flange NOTE: Should the finished wall protrude beyond the face of the unit, you can accommodate up to 1/2" depth. Simply push in the Full Screen Door Frame until it aligns against the finished wall.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 29 INST ALLA TION 10) Close screen doors. 8) Slide the Top Grill into the louver brackets located on the inside top of the firebox.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 30 4-7/16" Openings for electrical connections Power IN Millivolt Wires 5-1/2" 1-1/2" WIRING DIAGRAM CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 31 OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 32 COPY OF THE LIGHTING PLA TE INSTRUCTIONS OPERA TING INSTRUCTIONS 1 ) Push in the gas control knob slightly and turn clockwise to “OFF”.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 33 2) Turn gas control knob so indicator points to "OFF" position and allow 5 minutes for any gas in the combustion chamber to escape. 3) Turn gas control knob counterclockwise so indicator points to the "PILOT" position.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 34 MAINTENANCE WARNING The use of substitute glass will void all product warranties. Do not operate the appliance with the glass panel(s) re- moved, cracked or broken. Replacement of the glass panel(s) should be done by an authorized service person.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 35 REMOVING V AL VE 1) Shut off the gas supply. 2) Remove the louvers (and bay door if it is on). 3) Disconnect the inlet gas line. Note: Be sure to have an 11/16" wrench on the tee to ensure that the whole line is not twisted 4) Disconnect the 2 TP wires and the 2 TH wires from the valve.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 36 INST ALLING V AL VE 12) Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector. (Do not use open flame for leak testing.) 13) Fire up the unit. 14) Check the manifold pressure.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 37 P ARTS LIST P42 MAIN ASSEMBL Y Part # Description Part # Description Part # Description 1 ) 910-142 Fan - Auto ON/OFF Thermodisc 2 ) 820-389 T.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 38 P ARTS LIST P42 BURNER & LOG ASSEMBL Y Part # Description 602-574/P Valve Assembly - Natural Gas 602-576/P Valve Assembly - Propane 52 ) * Gasket - Valve Access Plate 56) 910-190 Piezo Ignitor & Nut 57) 910-378 Valve S.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 39 P42 FLUSH DOOR & LOUVERS Part # Description 600-960 Flush Louvers (Set) - Gold/Black 600-958 Flush Louvers (Set) - Black 600-961 Flush Lou.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 40 P42 BA Y FRONT & LOUVERS 603-930 Bay Front Complete with Glass & Black Trim 106) 940-102/P Side Glass 107) 936-243 Glass Gasket 108) 9.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 41 _____________________________________________________________________________________ ________________________________________________________.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 42 _____________________________________________________________________________________ ________________________________________________________.
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace 43 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility.
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ __________________________________________________________________ Instal.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Regency P42-LP3 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Regency P42-LP3 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Regency P42-LP3 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Regency P42-LP3 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Regency P42-LP3, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Regency P42-LP3.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Regency P42-LP3. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Regency P42-LP3 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.