Manuale d’uso / di manutenzione del prodotto P33-LP4 del fabbricante Regency
Vai alla pagina of 52
FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-520a MODELS: P33-NG4 Natural Gas P33-LP4 Propane P33-4 Zero Clearance Direct V ent Gas Fireplace 03/05/08 O.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 2 T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Fireplace by FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. The P33-4 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 3 T ABLE OF CONTENTS Full Screen Doors ....................................................... 35 Optional W all Thermostat .......................................... 37 Optional Remote Control .
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 4 SAFETY LABEL This is a copy of the label that accompanies each P33-4 Zero Clearance Direct V ent Gas Fireplace. We have printed a copy of the contents here for your review . The safety label is located on the front inside base of the unit, visible when the bottom louver is open.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 5 REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chapte r 10 (2) Revise 10.8. 3 by adding the fo llowing addit ional requireme nts: (a) For al.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 6 INST ALLA TION IMPORT ANT MESSAGE SA VE THESE INSTRUCTIONS The P33-NG4 or P3 3-LP4 Direct V ent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 7 DUCT SYSTEM OPTION kit #946-556 The HeatWave Air Duct Kit increases the effectiveness of your fi replace by dispersing warm air from the fi replace to remote locations in the same room or other rooms in your home.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 8 COMBUSTIBLE MANTELS Because of the extreme heat this fi replace emits, the mantel clearances are critical.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 9 INST ALLA TION 3) For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fi replace itself.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 10 The T op Facing Support, the Side Nailing Strips and the 2 T op Standof fs must be correctly positioned and attached to the top before the unit is put into position.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 11 EXTERIOR VENT TERMINA TION LOCA TIONS INST ALLA TION A= Clearance above grade, veranda, porch, deck , or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) C= Clearance to permanently closed window *(mi n.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 12 IMPORT ANT If using any Cabinet Mantels with Part # 510956, 510958, 510962, 510964 and 510834 the wall thimble must be secured fi rst and venting must be attached to unit before sliding into fi nal position.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 13 T ermination Cap W all Thimble 2 pieces (10" (254mm) Outer Diameter) 2 ”x4 ”o r2 ”x6 ” (21mm x 102mm or 21mm x 152mm) 6-7/8" (175mm) dia.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 14 Pipe Length V ertical T erminal Storm Collar Flashing Ceiling Firestop 24" Length Adj.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 15 INST ALLA TION 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 16 Description Simpson Direct V ent Pro ® Simpson Direct V ent GS ® Discontinued Selkirk Direct-T emp™ American Metal Products ® Amerive.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 17 • V ent must be supported at offsets. • Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles. Note: Must use optional rigid pipe adapter when using rigid vent systems (Part # 510-994).
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 18 The P33-4 is approved for a maximum 40 ft. straight vertical, with rigid pipe vent systems for Propane and Natural Gas.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 19 RIGID PIPE VENTING ARRANGEMENTS Horizontal T erminations REGENCY ® DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45 o and one 90 o elbow (two 45 o elbows equal one 90 o elbow).
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 20 Horizontal V enting with T wo (2) 90 o Elbows Horizontal V enting with T wo (2) 90 o Elbows Horizontal V enting with Three (3) 90 o Elbows INST ALLA TION One 90 o elbow = T wo 45 o elbows.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 21 Horizontal V enting with Three (3) 90 o Elbows V ertical V enting with T wo (2) 90 o Elbows V ertical V enting with T wo (2) 90 o Elbows INST ALLA TION For additional vertical venting with 2 x 90 o elbows, refer to "Rigid Pipe V enting Arrangements" Section.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 22 INST ALLA TION V ertical V enting with Three (3) 90 o Elbows V ertical V enting with Three (3) 90 o Elbows Option H V H + H1 V + V1 A) 1' Max. 1' Min. 3' Max. 3' Min. B) 2' Max.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 23 Flex Liner Exhaust Flue A maximum of two certified joiner kits may be used per length.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 24 VENTING ARRANGEMENTS - VERTICAL TERMINA TIONS with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 25 Riser V ent T ermination Min. 6-1/4"* (159mm) INST ALLA TION Diagram 3 UNIT INST ALLA TION WITH HORIZONT AL TERMINA TION Diagram 1 b) Horizontal runs of vent must be supported every three feet.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 26 INST ALLA TION GAS LINE INST ALLA TION The gas line is brought through the right side of the appliance. The gas valve is situated on the right hand side of the unit and the gas inlet is on the right hand side of the valve.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 27 GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve dur in g a ny pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 28 INST ALLA TION Each Kit contains one LPG Conversion Kit and one DC Sparker Kit. LPG Conversion Kit Contains: Qty .
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 29 INST ALLA TION W ARNING! Do not overtighten the screw . Recommended to grip the wrench by the short side. 7) T urn control knob to the “OFF” position. 8) Remove the black protection cap by hand from the high-low knob (Fig.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 30 INST ALLA TION 4) Connect the DC spark generator wires to the SIT V alve with the screw , which is provided in the kit. 5) Locate the ground lug at the receptical box, left of the unit. 6) Connect one end of the supplied green ground wire to the lug with the nut and washer from the kit.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 31 Note: The logs must not be in the unit. 3) Insert the back brick panel by carefully slipping it between the back wall of the fi rebox and the rear log bracket. OPTIONAL BRICK PA N E L S 1) Undo the bottom 2 door latches and open and remove glass door .
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 32 Diagram 1 Diagram 3 ST ANDARD FLUSH DOOR The standard fl ush door comes with a black frame. T o install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, diagram 1.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 33 OPTIONAL BA Y DOOR The Bay louvers MUST be used with the Bay glass option. The optional Bay door is an overlay on the fl ush front. The standard fl ush door and glass must remain on the unit.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 34 6) Open the bottom louver . Pull the Burner ON/OFF control box from inside the bottom of the fi replace and position the slots in the bracket over the 2 screws on the left side of the bottom louver .
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 35 FULL SCREEN DOORS 1) Before beginning the installation, remove the Glass Door from the unit. Refer to the manual for instructions. 2) Slide the Bottom Faceplate Bracket into the bottom of the unit, secure it into the pins located on the inside of the fi re box.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 36 6) Place the Bottom Frame near the hinges, and fl ip down the hinges from the Bottom Face Plate. Secure the hinges in place to the Bottom Frame, using 2x #8 Self T apping Phillips screws per hinge.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 37 Optional W ALL SWITCH 1) Run the supplied 15' of wire through the right or left side gas inlet opening. Be careful not to damage wire. Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wire T able.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 38 WIRING DIAGRAMS This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 39 Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 40 INST ALLING THE OPTIONAL F AN 120 V olt AC power is needed for the fan switch and blower . The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualifi ed electrician.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 41 OPERA TING INSTRUCTIONS COPY OF THE LIGHTING PLA TE INSTRUCTIONS Gas Inlet OFF Gas Inlet.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 42 AERA TION ADJUSTMENT The air shutter can be adjusted by moving the adjusting wire up or down. The wire is accessed through the bottom louver opening. Open the air shutter for a blue fl ame or close for a yellower fl ame.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 43 MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year .
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 44 MAINTENANCE THERMOPILE/ THERMOCOUPLE 1) Open the bottom louvers. 2) Loosen the thermocouple or thermopile with a 7/16" wrench. 3) Disconnect thermocouple by loosening nut from the valve with a 9mm wrench.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 45 REMOVING V AL VE 1) Shut off the gas supply . 2) Remove the louvers (and bay door if it is on). 3) Open the fl ush door and remove the door . 4) Remove the logs. 5) Remove the burner/grate assembly by removing the two Phillips head screws and then lift the burner assembly out.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 46 P ARTS LIST MAIN ASSEMBL Y Part # Description Part # Description Part # Description 1) 948-247 Door Handle 2) * Thermodisc Bracket 7) 910-.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 47 P ARTS LIST.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 48 BURNER & LOG ASSEMBL Y Part Description 53) 430-055 Gasket - V alve Access Plate - NG/LP 54) 910-421 Pilot ON/OFF Extension Knob 55) 9.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 49 P ARTS LIST FLUSH FRONT & LOUVERS Part # Description Part # Description 1 17) 904-196 Magnet - 1' round 131) 430-947 Flush Glass .
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 50 111 1 17 123 1 17 123 125 126 120 120 107 120 108 107 120 120 120 120 120 107 120 120 106 120 106 120 120 120 129 129 11 8 107 11 7 11 7 1.
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 51 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility .
Regency ® P33-4 Zero Clearance Direct V ent Gas Fireplace 52 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Regency P33-LP4 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Regency P33-LP4 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Regency P33-LP4 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Regency P33-LP4 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Regency P33-LP4, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Regency P33-LP4.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Regency P33-LP4. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Regency P33-LP4 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.