Manuale d’uso / di manutenzione del prodotto L676E-NG del fabbricante Regency
Vai alla pagina of 48
Unit requires 120V to operate. See “Wiring Diagram” section in manual for more details. Receptacle is included with manual package. T ested by: FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD.
Regency ® L676E Direct V ent Gas Fireplace 2 T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The L676E has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
Regency ® L676E Direct V ent Gas Fireplace 3 T ABLE OF CONTENTS SAFETY LABEL Copy of Safety Decal ..................................................... 4 REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) .......................
Regency ® L676E Direct V ent Gas Fireplace 4 INST ALLA TION SAFETY LABEL This is a copy of the label that accompanies each L676E-NG and L676E-LP Direct V ent Gas Fireplace.
Regency ® L676E Direct V ent Gas Fireplace 5 INST ALLA TION REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chapter 10 (2) Revise 10.8. 3 by adding the follow ing additiona l requirements: (a) For all .
Regency ® L676E Direct V ent Gas Fireplace 6 INST ALLA TION UNIT DIMENSIONS.
Regency ® L676E Direct V ent Gas Fireplace 7 INST ALLA TION 12) Installation and any repairs to this appliance should be done by an authorized service person. A professional service person should be called to inspect this appliance annually . Make it a practice to have all of your gas appliances checked annually .
Regency ® L676E Direct V ent Gas Fireplace 8 INST ALLA TION INST ALLA TION This includes: 1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label 42,000 (NG) Btu/h, 40,000 (LP) Btu/h) after burning appliance for 15 minutes.
Regency ® L676E Direct V ent Gas Fireplace 9 INST ALLA TION INST ALLA TION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials.
Regency ® L676E Direct V ent Gas Fireplace 10 INST ALLA TION INST ALLA TION MANTEL CLEARANCES Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram below .
Regency ® L676E Direct V ent Gas Fireplace 11 INST ALLA TION INST ALLA TION Diagram 1 1) Frame in the enclosure for the unit with framing material. The framed opening for the assembled kit is 45-7/8" high x 48" wide x 24-1/4" deep (1 143mm x H 1219mm W x 616mm D).
Regency ® L676E Direct V ent Gas Fireplace 12 INST ALLA TION INST ALLA TION SIDE NAILING STRIPS The side nailing strips come attached to the unit. There are 3 plates, one on the top and bottom that can be folded out as required.
Regency ® L676E Direct V ent Gas Fireplace 13 INST ALLA TION V ent restriction is required for certain venting installations, see the diagrams in the "V enting Arrangements" section to determine if they are required for your installation. The V ent Restrictor plate is located on the inside top of the fi rebox.
Regency ® L676E Direct V ent Gas Fireplace 14 INST ALLA TION EXTERIOR VENT TERMINA TION REQUIREMENTS A= Clearance above grade, veranda , porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #( 9 "/23cm) C= Clearance to permanently closed window *(min.
Regency ® L676E Direct V ent Gas Fireplace 15 INST ALLA TION VENTING ARRANGEMENTS HORIZONT AL TERMINA TION (FLEX) Regency ® Direct V ent System These venting systems, in combination with the L676E, have been tested and listed as a direct vent heater system by Intertek.
Regency ® L676E Direct V ent Gas Fireplace 16 INST ALLA TION RIGID PIPE VENTING SYSTEMS BASIC HORIZONT AL & VERTICAL TERMINA TIONS Rigid Pipe V ent Systems offer a complete line of component parts for installation of both horizontal and vertical installations.
Regency ® L676E Direct V ent Gas Fireplace 17 INST ALLA TION INST ALLA TION Description Simpson Direct V ent Pro ® Simpson Direct V ent GS ® Discontinued Selkirk Direct-T emp™ Metal-Fab ® Sure S.
Regency ® L676E Direct V ent Gas Fireplace 18 INST ALLA TION L676 & L900 Direct V ent Fireplace IMPORT ANT NOTE • A V ent Guard is required when the AstroCap is installed above grade at 7 feet or lower. • The Simpson Dura-V ent and Selkirk Direct T emp horizontal termination caps cannot be used in any applications.
Regency ® L676E Direct V ent Gas Fireplace 19 INST ALLA TION VENTING ARRANGEMENTS ALLOW ABLE HORIZONT AL TERMINA TIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 o two 45 o elbows equal one 90 o elbow).
Regency ® L676E Direct V ent Gas Fireplace 20 INST ALLA TION Horizontal V enting with T wo (2) 90 o Elbows Horizontal V enting with Three (3) 90 o Elbows One 90 o elbow = T wo 45 o elbows. Option V H + H1 A) 2' Min. 4' Max. B) 3' Min. 5' Max.
Regency ® L676E Direct V ent Gas Fireplace 21 INST ALLA TION V ertical V enting with T wo (2) 90 o Elbows V ertical V enting with Three (3) 90 o Elbows Option V H V + V1 A) 2' Min. 2' Max. 3' Min. B) 2' Min. 10' Max. 6' Min.
Regency ® L676E Direct V ent Gas Fireplace 22 INST ALLA TION VENTING ARRANGEMENTS ALLOW ABLE VERTICAL TERMINA TIONS • V ent must be supported at offsets. • Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles as listed in the "Clearances" section.
Regency ® L676E Direct V ent Gas Fireplace 23 INST ALLA TION INST ALLA TION Diagram 7 Diagram 5 7) Ensure that the pipe clearances to combustible materials are maintained (Diagram 5).
Regency ® L676E Direct V ent Gas Fireplace 24 INST ALLA TION INST ALLA TION 6) Continue to assemble pipe lengths. Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (0.9 meter), to avoid excessive stress on the elbows, and possible separation.
Regency ® L676E Direct V ent Gas Fireplace 25 INST ALLA TION INST ALLA TION 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall.
Regency ® L676E Direct V ent Gas Fireplace 26 INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve d uring any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
Regency ® L676E Direct V ent Gas Fireplace 27 INST ALLA TION BACK-UP BA TTER Y INST ALLA TION INST ALLA TION 4) Lift the heat shield up and pull out slightly to clear the head screws and then hang it on the top bracket (located directly above the heat shield, close to the top of the fi rebox).
Regency ® L676E Direct V ent Gas Fireplace 28 INST ALLA TION BRICK P ANEL INST ALLA TION IMPORT ANT : Must install 1 set of brick panels. The operation of this unit without the brick panels is prohibited. Dangerous operating conditions may occur if the panels are broken.
Regency ® L676E Direct V ent Gas Fireplace 29 INST ALLA TION 7) Slide the left side brick panel into position and secure in place with the brick panel clip that was removed in step 3. 1) Ensure installation of the logs and glass door has been completed before installing the exterior brick panels.
Regency ® L676E Direct V ent Gas Fireplace 30 INST ALLA TION LOG SET INST ALLA TION Installation of Interior Brick Panels must be completed before installing the log set. INST ALLA TION Read the instructions below carefully and refer to the diagrams.
Regency ® L676E Direct V ent Gas Fireplace 31 INST ALLA TION INST ALLA TION 6) Spread all of the Embers on the bottom brick panel around the burner tube and inbetween the front burner tube and the grate as shown. Separate platinum embers and place on the embers around the burner tube and inbetween the front burner tube and grate.
Regency ® L676E Direct V ent Gas Fireplace 32 INST ALLA TION INST ALLA TION WIRING DIAGRAM A receptacle is provided on the left hand side of the unit. 120 V olt AC power must be wired to the receptacle and the control module plugged in for the unit to operate fully .
Regency ® L676E Direct V ent Gas Fireplace 33 OPERA TION OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock.
Regency ® L676E Direct V ent Gas Fireplace 34 OPERA TION 1) Plug the power cord into a power outlet. 2) Press and release the ON/OFF button once on the Remote Control. 3) After approximately 3 seconds the spark ignition system will spark for 30 seconds to light the main burner .
Regency ® L676E Direct V ent Gas Fireplace 35 OPERA TION OPERA TING INSTRUCTIONS COPY OF LIGHTING PLA TE INSTRUCTIONS TO TURN OFF GAS APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS A) BEFORE LIGHTING smell all around the appliance area for gas.
Regency ® L676E Direct V ent Gas Fireplace 36 MAINTENANCE MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year .
Regency ® L676E Direct V ent Gas Fireplace 37 MAINTENANCE BACK-UP BA TTER Y REPLACEMENT MAINTENANCE 2) Lift the heat shield up and pull out slightly to clear the head screws and then hang it on the top bracket (located directly above the heat shield, close to the top of the fi rebox).
Regency ® L676E Direct V ent Gas Fireplace 38 MAINTENANCE 4) Disconnect both sources of power; the power cord, located on the left hand side of the fi rebox and the wires connected to the back-up battery located on the right side of the fi rebox.
Regency ® L676E Direct V ent Gas Fireplace 39 MAINTENANCE 1) Remove the exterior brick panels. 2) Remove the glass door . a. Release the 2 door latches on the left and right side at the top of the fi rebox. b. Swing the door out from the top and release the hinges on the left and right side of the door by lifting them up.
Regency ® L676E Direct V ent Gas Fireplace 40 MAINTENANCE 9) Carefully remove the bottom brick panel. Bottom Brick Panel 11 ) Lift the heat shield up and pull out slightly to clear the head screws and then hang it on the top bracket (located directly above the heat shield, close to the top of the fi rebox).
Regency ® L676E Direct V ent Gas Fireplace 41 MAINTENANCE 18) Disconnect the black and red wires from the solenoid valve. 17) Remove the 16 screws that hold the valve tray to the fi rebox and carefully pull out the valve tray . V alve T ray 16) Disconnect the spark cable and valve sensor wires from the control board.
Regency ® L676E Direct V ent Gas Fireplace 42 P AR TS LIST P ARTS LIST MAIN ASSEMBL Y Part # Description 1) 521-527 Flue Collar Inner Assembly 2) 502-008 Flue Collar Outer 5) 904-751 Cap Screws 1/4&q.
Regency ® L676E Direct V ent Gas Fireplace 43 P AR TS LIST BURNER & LOG ASSEMBL Y Part # Description 30) 521-015 Bracket Log T ray 31) 521-016 Log T ray 32) 521-042 Defl ector Log T ray 35) 948-.
Regency ® L676E Direct V ent Gas Fireplace 44 NOTES.
Regency ® L676E Direct V ent Gas Fireplace 45 NOTES.
Regency ® L676E Direct V ent Gas Fireplace 46 NOTES.
Regency ® L676E Direct V ent Gas Fireplace 47 W ARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam care fully inspects each unit thoroughly before it leaves our facility .
Regency ® L676E Direct V ent Gas Fireplace 48 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ __________________________.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Regency L676E-NG è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Regency L676E-NG - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Regency L676E-NG imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Regency L676E-NG ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Regency L676E-NG, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Regency L676E-NG.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Regency L676E-NG. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Regency L676E-NG insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.