PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Models: IG35-NG IG35-LPG IG35-ULPG Owners & Installation Manual 06/23/08 LISTINGS AND CODE APPROV ALS These gas appliances have been tested in a.
2 Regency IG35 Gas Inbuilt Fireplace REGENCY GAS INBUIL T FIREPLACE TO THE NEW OWNER Congratulations! Y ou are the owner of a state-of-the-art Gas Inbuilt Fireplace by FPI. The Regency Gas Fireplace Series of appliances has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch.
3 Regency IG35 Gas Inbuilt Fireplace T ABLE OF CONTENTS REGENCY GAS FIREPLACE INSERT DA T A BADGE Data Badge.................................................................... 5 INST ALLA TION Important Message .......................................
4 Regency IG35 Gas Inbuilt Fireplace DA T A BADGE (Australia Only) This is a copy of the label that accompanies each Regency IG35 Gas Inbuilt fi replace. We have printed a copy of the contents here for your review . DA T A BADGE NOTE: Regency units are con- stantly being improved.
5 Regency IG35 Gas Inbuilt Fireplace INST ALLA TION IMPORT ANT MESSAGE The Regency Gas Fireplace must be installed in accordance with these instructions.
6 Regency IG35 Gas Inbuilt Fireplace INST ALLA TION GAS CONNECTION 3) Locate the center point where the fl ue will pass through the chimney above the appli- ance. Move the appliance into the exact location where it is to be installed. Ensure that the Insert is level.
7 Regency IG35 Gas Inbuilt Fireplace INST ALLA TION FLUEING THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEP ARA TE SOLID FUEL BURNING APPLIANCE. This appliance is designed to attach to a 100 mm diameter twin skin or listed gas fuel type fl ue liner running the full length of the chimney .
8 Regency IG35 Gas Inbuilt Fireplace TEST FOR FLUE SPILLAGE A " spillage" test must be made before the installed unit is left with the customer . Follow the procedure below: 1) Start all exhaust fans in the home and then close all external doors and windows in the house.
9 Regency IG35 Gas Inbuilt Fireplace INST ALLA TION Conversion Kit #486-968 for NG to LPG Model THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit 486-968 Contains: Qty .
10 Regency IG35 Gas Inbuilt Fireplace 16) T urn on gas supply and plug in power cord. Installer Notice: These instructions must be left with the appliance. 17) Adjusting the Outlet Pressure All the adjustments must be carried out in the following order: Remove the modulator plastic cap (A) using needle nose pliers.
11 Regency IG35 Gas Inbuilt Fireplace Conversion Kit #486-967 for NG to ULPG THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit 486-967 Contains: Qty .
12 Regency IG35 Gas Inbuilt Fireplace 16) T urn on gas supply and plug in power cord. Installer Notice: These instructions must be left with the appliance. 17) Adjusting the Outlet Pressure All the adjustments must be carried out in the following order: Remove the modulator plastic cap (A) using needle nose pliers.
13 Regency IG35 Gas Inbuilt Fireplace The "02" refer numbers (i.e. 02-65) are molded into the rear of each log. 1) Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position. 2) Sprinkle the embers on the front, left and right sides of the fi rebox base.
14 Regency IG35 Gas Inbuilt Fireplace Notch E)02-45 Bracket A)02-65 The bottom right edge of Log G)02-48 must sit snugly against the bracket Side V iew G)02-48 E)02-45 F)02-47 11 ) Position notch in Front Right Log G)02-48 on Log F)02-47 and push the bottom right edge against the bracket on the burner tray .
15 Regency IG35 Gas Inbuilt Fireplace Diagram 1 F ACEPLA TE, TRIM & LOUVER INST ALLA TION 1) Lay the faceplate panels fl at, face down on something soft so they don't scratch. 2) T ake the top faceplate and align the holes in it with the holes in the side panels.
16 Regency IG35 Gas Inbuilt Fireplace PREMIUM FLUSH FRONT INST ALLA TION 6) Place the ECS manual control switch key pad on the outside of the opening in the faceplate and the control switch to the inside of the faceplate. Align the holes and secure in place using the 2 bolts, washers, phenolic spacers, split lock washers and nuts.
17 Regency IG35 Gas Inbuilt Fireplace 11 ) Place the cable ties thru the cable tie holders in the heat shield loosely to secure loose wires. Run the CA T5 cable from the unit thru the cable ties on the heat shield and tighten cable ties. Ensure not to overtighten.
18 Regency IG35 Gas Inbuilt Fireplace Heat Defl ector T ab into T ab Bracket Diagram 1 1 15) Completely mount the faceplate to the unit. .See diagram 13. Diagram 13 Faceplate Installation: 16) Secure the faceplate in place using 2 screws on the left and right side.
19 Regency IG35 Gas Inbuilt Fireplace 19) Carefully lift off the ignition module from the velcro and slightly bring forward. Remove the wire harness connected to the ignition module as shown in diagram 17. Diagram 17 Ignition Module 20) Discard the complete wire harness that was connected to the valve and ignition module.
20 Regency IG35 Gas Inbuilt Fireplace 25) Secure all loose wires in the wire clip to the right side of the valve. See diagram 23. Diagram 23 26) Secure the hinge bracket and hinge to the outside of the fi rebox fl ange on the left and right side as shown using 2 screws on each side.
21 Regency IG35 Gas Inbuilt Fireplace REMOTE CONTROL Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty .
22 Regency IG35 Gas Inbuilt Fireplace WIRING WITH PREMIUM FLUSH FRONT OPTION CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
23 Regency IG35 Gas Inbuilt Fireplace OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS Before operating this appliance, proceed through the following check list. 1) Read and understand these Instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock.
24 Regency IG35 Gas Inbuilt Fireplace COPY OF LIGHTING INSTRUCTION PLA TE OPERA TING INSTRUCTIONS NORMAL OPERA TING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance.
25 Regency IG35 Gas Inbuilt Fireplace MAINTENANCE CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV - ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERA T - ING THE APPLIANCE. CLOTHING OR OTHER FLAM- MABLE MA TERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
26 Regency IG35 Gas Inbuilt Fireplace MAINTENANCE F AN MAINTENANCE T o Remove Fan: 1) Turn the unit of f and allow it to cool to room temperature, 2) Unplug or disconnect power source to stove. 3) Open the bottom louvre. 4) Remove the ECS harness from the back clip.
27 Regency IG35 Gas Inbuilt Fireplace MAINTENANCE REMOVING V AL VE TRA Y 1) Unplug or disconnect the power source to the stove. 2) Shut off the gas supply and remove the gas connection from the valve. 3) Remove the top louvre. 4) Remove the safety screen.
28 Regency IG35 Gas Inbuilt Fireplace P ARTS LIST ELECTRONIC COMPONENTS P ARTS LIST 910-936 910-082 910-088 910-089 910-084 910-527 910-935 910-080 910-521, 910-522, 910-523, 910-525 910-912 910-906 9.
29 Regency IG35 Gas Inbuilt Fireplace MAIN ASSEMBL Y Part # Description Part # Description 1) 910-169/P Fan Motor (240 V) 2) 910-714 Power Cord 240 V olts 3) 820-389 Thermodisc Bracket 5) 910-006 T er.
30 Regency IG35 Gas Inbuilt Fireplace P ARTS LIST F ACEPLA TE ASSEMBL Y Part # Description Part # Description 87) 910-140 Fan HI/OFF/LOW Switch 88) 910-246 Burner ON/OFF Switch 486-918 Faceplate &.
31 Regency IG35 Gas Inbuilt Fireplace W ARRANTY Exclusions: This limited Lifetime W arranty does not extend to or include paint, door or glass gasketing or trim.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Regency IG35-ULPG è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Regency IG35-ULPG - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Regency IG35-ULPG imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Regency IG35-ULPG ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Regency IG35-ULPG, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Regency IG35-ULPG.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Regency IG35-ULPG. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Regency IG35-ULPG insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.