FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 04/04/08 T ested by: Installer : Please complete the details on the back cover and leave this manual with the homeowner . Homeowner: Please keep these instructions for future reference.
FPI FP90 Wood Fireplace 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. This product has been certifi ed by the Environmental Protection Agency of the United States.
FPI FP90 Wood Fireplace 3 T ABLE OF CONTENTS SAFETY LABEL Safety Label For FP90 .................................................. 4 INST ALLA TION Product Details .............................................................. 5 Read Before Y ou Install .
FPI FP90 Wood Fireplace 4 SAFETY LABEL SAFETY LABEL FOR FP90 This is a copy of the label that accompanies each Regency Fireplace. It is located inside the lower louver opening on the left side. We have printed a copy of the contents here for your review .
FPI FP90 Wood Fireplace 5 INST ALLA TION INST ALLA TION PRODUCT DET AILS EP A Certifi ed Emissions : 3.72 g/hr Effi ciency (EP A) : 63% BTU/HR (EP A) : 1 1,720 (Lo) to 42,400 (Hi) Flue Size : 8".
FPI FP90 Wood Fireplace 6 INST ALLA TION INST ALLA TION 6) Use solid fuel only . DO NOT use artifi cial logs containing petroleum products, chemical chimney cleaners, gas logs, gas lighters, salt contaminated wood or fl ame colorants in your fi replace.
FPI FP90 Wood Fireplace 7 INST ALLA TION 38" 43- 5/ 8" 14- 5/ 8" 13-3/8" 28" 9- 5/8" 25" 15" 4- 3/4" 50- 1/2" (1283mm) 42- 5/8" 3- 5/8" 1- 3.
FPI FP90 Wood Fireplace 8 INST ALLA TION No Combustibles on Face of Unit. Combustibles May Not Extend to Unit Face. Do not notch wallboard around standoffs.
FPI FP90 Wood Fireplace 9 INST ALLA TION Building Structures Cannot Encroach on Chase 50-3/4" (1289mm) 44" (1118mm) INST ALLA TION OF NAILING STRIPS 1) Assemble 3 Nailing Strip Spacer Plates to the left and the right Nailing Strips as shown below .
FPI FP90 Wood Fireplace 10 INST ALLA TION Fire S top FireStop Straightrun for 8"(203mm) Hot Air Duct Unit projects out flush with non-combustible material 2 x 4 Framing 2 x 6 Framing 10" 2x6.
FPI FP90 Wood Fireplace 11 INST ALLA TION V entilated Chase Pan BEFORE YOU ST ART Check your inventory list to be sure you have all the necessary parts supplied in good usable condition. Check for any concealed damage. Check the operation of the combustion air damper .
FPI FP90 Wood Fireplace 12 INST ALLA TION INST ALLA TION MEASUREMENTS / FRAMING DET AILS INST ALLA TION 3" (76mm) ST AND-OFF 2x4 FRAMING FRONT OF UNIT ONL Y COMBUSTION AIR TO OUTSIDE 38" (965mm) 19" (483mm) 30" (762mm) 60" (1524mm) WIDE INSIDE MIN.
FPI FP90 Wood Fireplace 13 INST ALLA TION There is also 1" unit base standoffs that are supplied with the unit. These are optional and are to be used to raise the unit.
FPI FP90 Wood Fireplace 14 INST ALLA TION The performance of your unit is governed to a very large extent by the chimney system. T oo short a chimney can produce poor drafting which in turn can cause diffi cult start-up, dirty glass, smoking out door and even reduced heat output.
FPI FP90 Wood Fireplace 15 INST ALLA TION INST ALLING THE OUTSIDE AIR KIT Combustion air is fed to the fi rebox through a connection on the rear lower left side of the unit. A free fl owing supply of air must be available to this opening at all times.
FPI FP90 Wood Fireplace 16 INST ALLA TION Plan View Jakel AX-2495 Blower Angle View Fan Transfer Plate Right View Front View Fan 910-175 AX-3088 910-903 910-516 Ground Neutral - from Fan 910-811 Therm.
FPI FP90 Wood Fireplace 17 INST ALLA TION Flex Vent Discharge Vent Grille Discharge Vent Frame Connecting Collar Clamp Flex Vent Insulation Strips 1) Remove the screw from the vent hole cover (vent cover 'A') on top of the unit. 2) T ake the connector collar and press and rotate it into the hole to cut through the insulation layer .
FPI FP90 Wood Fireplace 18 INST ALLA TION . . . . . . . . . . . . . Metal Filler Strips Metal Filler Strips MIDDLE UP TOP UP LEFT SIDE UP RIGHT SIDE UP A C B B Non-Combustible Material 2" (51mm) x 4" (102mm) Masonry Retainer Kit Option For a non-selfsupporting veneer fi nish only .
FPI FP90 Wood Fireplace 19 INST ALLA TION Non-Combustible Material Metal Filler Strips Stand-off Spacers Metal Filler Strip 60" (1524mm) C A B B 3/4" (19mm) 2-1/2" (64mm) 1-1/4"(32.
FPI FP90 Wood Fireplace 20 INST ALLA TION Side Panel To p Panel Insulation To p Brick Bottom V ermiculite MASONR Y LINER / BRICKS Insulated refractory panels are included to extend the life of the fi replace and help radiate heat more evenly . Make sure Insulating Paper is in place along the bottom, side and rear before bricks are put into place.
FPI FP90 Wood Fireplace 21 INST ALLA TION ASH DRA WER KIT OPTION During constant use, ashes should be removed every few days. The Ash Drawer Kit option provides a convenient and easy way to keep your wood stove clean. This ash drawer kit can only be used with the fi replace unit.
FPI FP90 Wood Fireplace 22 INST ALLA TION F AN INST ALLA TION NOTE: If optional Ashtray is installed, it must be removed before installing the fan. The receptacle Box must be wired for the fan cable to be plugged into. 1) Remove the thumb screw from the fan transfer tray .
FPI FP90 Wood Fireplace 23 INST ALLA TION MASONR Y COVER PLA TE INST ALLA TION 5° INSTALL FOUR #8x1/2 SCREWS AT THESE LOCATIONS TO ATTACH THE SURROUND TEMPLATE SIDES TO THE TOP. NOTE: SIDES SHOULD BE ASSEMBLED FLANGES ARE ON THE SLOTTED HOLES ON RIGHT SIDE ONLY 43.
FPI FP90 Wood Fireplace 24 INST ALLA TION WITH THE SAME MOUNTING SCREWS AS THE SURROUND. INSTALL THE SURROUND TEMPLATE ONTO THE UNIT WARNING: KEEP MASONRY MATERIAL AT LEAST 1/2" (13mm) FROM THIS TOP FACING GUIDE.
FPI FP90 Wood Fireplace 25 INST ALLA TION FINISHING TRIM KIT INST ALLA TION 2x4 FRAMING LEFT SIDE TRIM RIGHT SIDE TRIM 2x4 FRAMING TOP TRIM STEP #1 NON-COMBUSTIBLE AREA 60"W x 51-5/8"H (1524mm W x 1311mm H) 2x4 HEADER (ON EDGE) STEP #2 1) Unit must be installed correctly according to the specifi cation in the manual.
FPI FP90 Wood Fireplace 26 INST ALLA TION 2) Make sure the insulation under the top stand-off is up against the back of the top nailing strip. 3) Fasten the nailing strips to the framing. 4) Install both the left and right side trim (see labels for orientation).
FPI FP90 Wood Fireplace 27 INST ALLA TION FIREPLACE SCREEN INST ALLA TION INSTALLING THE HANDLES ON THE SCREEN 1) 1 or 2 handles can be installed on the screen. Layout location of the handle using the backing plate as a guide and widen two holes in the screen with a screw driver to let the screws for the handle through.
FPI FP90 Wood Fireplace 28 INST ALLA TION REGENCY LOUVER INST ALLA TION Installing the T op Louver 1) Add two (2) screws (¼-20 X ½”) to the front of the fi replace for mounting the top louver . The screws must be left loose to allow the top louver to slide onto them.
FPI FP90 Wood Fireplace 29 INST ALLA TION Installing the Facing Guide 1) Secure the left and right facing guides to the fi re- place with seven (7) screws (#10 x 1”) on each side. Holes must be pre-drilled. 2) Install the top louver opening adapter to the face of the unit with fi ve (5) screws (¼-20 x ½”).
FPI FP90 Wood Fireplace 30 INST ALLA TION EXCALIBUR ACCENT KIT INST ALLA TION 3) Remove the 2 studs on the sides of the Hood. Insert the new studs through the holes and secure them by fi rst putting on the washer and then tighten the nut. 1) Remove the handles by removing the nut and screw .
FPI FP90 Wood Fireplace 31 HEA TW A VE KIT HEA TW A VE KIT (NOT EP A APPROVED) Diagram 1: Guide for possible air duct runs and locations. Keep duct length and number of bends to a miniumum. Maximum duct length is 20 ft. (6.1m) per kit. LISTINGS AND CODE APPROV ALS This Kit has been approved for use with Models EX90 / R90.
FPI FP90 Wood Fireplace 32 HEA TW A VE KIT HEA TW A VE KIT (NOT EP A APPROVED) MINIMUM FRAMING CLEARANCES * W all studs must be 16" on center for mounting fan housing. * Fan Housing: Maintain a 1/4" (6mm) clearance from fan housing to combustible material.
FPI FP90 Wood Fireplace 33 HEA TW A VE KIT HEA TW A VE KIT (NOT EP A APPROVED) Diagram 4 4) Install the variable speed Wall Rheostat (with OFF setting) in a convenient location. This switch controls the fan operation. 5) Wire 120V AC service to the W all Rheostat and from the W all Rheostat to the Fan Junction Box.
FPI FP90 Wood Fireplace 34 OPERA TION OPERA TING INSTRUCTIONS Draft Control Both the primary and air wash drafts are controlled by the control rod located behind the bottom louver . T o increase your draft, pull to the right for open , to decrease push to the left for closed.
FPI FP90 Wood Fireplace 35 MAINTENANCE PLA TED FINISHES The optional plated fi nishes on the louvers and surrounds requires little maintenance and needs only to be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty .
FPI FP90 Wood Fireplace 36 P ARTS LIST P ARTS LIST P ARTS LIST - FIREBOX & BODY 16 12 13 15 14 4 2 1 8 7 6 5 3 Part # Description 1) 001-127 Heat Deflector Top 001-128 Stand Off Top - Right Side 0.
FPI FP90 Wood Fireplace 37 P ARTS LIST P ARTS LIST P ARTS LIST - BAFFLES, DOOR, OPTIONS Steel Handle - Left Door Steel Handle - Right Door Anchor Bracket - Left Handle Door Latch [Double] Double Door .
FPI FP90 Wood Fireplace 38 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________.
FPI FP90 Wood Fireplace 39 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our door . FPI Fireplace Products International Ltd.
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Insta.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Regency FP90 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Regency FP90 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Regency FP90 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Regency FP90 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Regency FP90, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Regency FP90.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Regency FP90. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Regency FP90 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.