05/18/06 Freestanding Gas Stove FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appli- ance Do not touch any electri- cal switch: do not use any phone in your building. Immediately call your gas supplier from a neighbour's phone.
2 Regency ® F39 Room Sealed Freestanding Gas Stove T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Regency ® Room Sealed Gas Stove by FPI Fireplace Products International Ltd.
Regency ® F39 Room Sealed Freestanding Gas Stove 3 T ABLE OF CONTENTS OPERA TING INSTRUCTIONS Operating Instructions ................................................ 22 Lighting Instructions .................................................... 22 Shutdown Instructions .
4 Regency ® F39 Room Sealed Freestanding Gas Stove SAFETY LABEL This is a copy of the label that accompanies each REGENCY F39 Room Sealed Freestanding Gas Stove. We have printed a copy of the contents here for your review . The data plat is located on the inside of the drop down pedestal door .
Regency ® F39 Room Sealed Freestanding Gas Stove 5 IMPORT ANT SA VE THESE INSTRUCTIONS The REGENCY Room Sealed Freestanding Gas Stove must be installed in accordance AG601 and NZS 5261 and with these instruc- tions. Carefully read all the instructions in this manual fi rst.
6 Regency ® F39 Room Sealed Freestanding Gas Stove INST ALLA TION Before leaving this unit with the customer , the installer must ensure that the appliance is fi r- ing correctly and operation fully explained to customer .
Regency ® F39 Room Sealed Freestanding Gas Stove 7 LOUVER INST ALLA TION 1) Attach the top & bottom louvres to the side stove panel using 2 screws per side.
8 Regency ® F39 Room Sealed Freestanding Gas Stove INST ALLA TION EXTERIOR FLUE TERMINA TION LOCA TIONS Minimum clearances required for balanced fl ue terminals or the fl ue terminals of outdoor ap.
Regency ® F39 Room Sealed Freestanding Gas Stove 9 INST ALLA TION FLUING ARRANGEMENTS V ertical T erminations Using Dura-Flue Fluing System for Residential Manufactured and Mobile Homes The shaded area in the diagram below shows all allowable combi- nations of straight vertical and offset to vertical runs with vertical terminations.
10 Regency ® F39 Room Sealed Freestanding Gas Stove INST ALLA TION DV ST OVE HORIZONT AL FLUE KIT (# 946-1 12) INST ALLA TION Minimum Installation Height: F39: 59-3/4" ( 1518mm) Review the following sequence of instructions which are typical of most installations.
Regency ® F39 Room Sealed Freestanding Gas Stove 11 INST ALLA TION when cut will seat onto both the starter collar and the 90 o elbow . Crimped section of rigid pipe seats into the 90 o elbow . Only cut the uncrimped side of pipe. Dismantle all pipe sections including fl ue terminal.
12 Regency ® F39 Room Sealed Freestanding Gas Stove Pipe Length Round Support Box/W all Thimble (Part # 940) Round Support Box/ W all Thimble (Part # 940) V ertical T erminal S torm Collar Part # 953 Flashing 943 or 943S Ceiling Firestop (Part # 963) 24" (610mm) Pipe Length Adj.
Regency ® F39 Room Sealed Freestanding Gas Stove 13 Diagram 5 Note: If installing termination on a siding covered wall, a vinyl siding standoff or fur- ring strips must be used to ensure that the termination is not recessed into the siding.
14 Regency ® F39 Room Sealed Freestanding Gas Stove Diagram 1 1: The upper half of the fl ashing is installed under the roofi ng material and not nailed down until the chimney is installed.
Regency ® F39 Room Sealed Freestanding Gas Stove 15 GAS CONNECTION The gas connection is a 3/8" NPT 90 o elbow . The gas line can be rigid pipe or to make in- stallation easier , use a listed fl exible connector and/or copper tubing if allowed by local codes.
16 Regency ® F39 Room Sealed Freestanding Gas Stove Burner Inlet Orifi ce Sizes: NG LPG Burner #32 #50 2.95mm 1.78mm Max. Input NG 40 Mj/h LPG 38 Mj/h Min. Input NG 20 Mj/h LPG 19 Mj/h Supply Pressure NG min. 1.13 kPa LPG min. 2.75 kPa Manifold Pressure NG .
Regency ® F39 Room Sealed Freestanding Gas Stove 17 INST ALLA TION CONVERSION KIT #731-968 FROM NG T O LPG THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! W ARNING! Do not over tighten the screw . Recommended to grip the wrench by the short side.
18 Regency ® F39 Room Sealed Freestanding Gas Stove LOG SET INST ALLA TION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.
Regency ® F39 Room Sealed Freestanding Gas Stove 19 Notch E)02-45 Bracket A)02-65 The bottom right edge of Log G)02-48 must sit snugly against the bracket Side V iew G)02-48 E)02-45 F)02-47 11 ) Position notch in Front Right Log G)02-48 on Log F)02-47 and push the bottom right edge against the bracket on the burner tray .
20 Regency ® F39 Room Sealed Freestanding Gas Stove OPTIONAL W ALL THERMOST A T A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams.
Regency ® F39 Room Sealed Freestanding Gas Stove 21 WIRING CAUTION: Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation.
22 Regency ® F39 Room Sealed Freestanding Gas Stove ADJUSTING FLAME HEIGHT Y our heater has an adjustable fl ame to tailor the look and heat output to your specifi c needs. It is adjusted by turning the fl ame adjustment dial on the gas control valve.
Regency ® F39 Room Sealed Freestanding Gas Stove 23 NORMAL OPERA TING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance.
24 Regency ® F39 Room Sealed Freestanding Gas Stove MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year .
Regency ® F39 Room Sealed Freestanding Gas Stove 25 Mitred Glass Replacement Removing Glass 1) Remove the door from the unit and place on a soft surface to prevent scratching. 2) Pull out the door gasket. 3) Remove the 24 nuts holding the glass retainers in place.
26 Regency ® F39 Room Sealed Freestanding Gas Stove MAINTENANCE F AN MAINTENANCE If your fan requires maintenance or replacement, access to the fan is through the plate on the rear wall of the fi rebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed.
Regency ® F39 Room Sealed Freestanding Gas Stove 27 REMOVING V AL VE 2) Undo the six screws holding the control panel in place. 3) Disconnect all wires from the back of the panel and then remove panel. Y ou should lay the panel on a soft cloth so it doesn't get marked up.
28 Regency ® F39 Room Sealed Freestanding Gas Stove P ARTS LIST 31) 630-021 Fan Access Panel 32) 730-028 Firebox Baffl e 33) 630-520 False T op Assembly 36) 936-194 Gasket - Starter Collar/ Air Pass.
Regency ® F39 Room Sealed Freestanding Gas Stove 29 F39 BURNER & LOG ASSEMBL Y 52) 910-190 Piezo Ignitor & Nut 54) 910-373 Knob - Pilot V alve Extension 55) 910-372 Flame Adjusting Knob 56) 918-088 Control Plate Decal 57) * Switch Plate 730-574/P V alve Assembly - NG 60) 910-378 V alve - S.
30 Regency ® F39 Room Sealed Freestanding Gas Stove P ARTS LIST F39 DOOR ASSEMBLIES Part # Description 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door .
Regency ® F39 Room Sealed Freestanding Gas Stove 31 WA R R A N T Y Exclusions: This limited Lifetime W arranty does not extend to or include paint, door or glass gasketing or trim.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Regency F39-NG è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Regency F39-NG - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Regency F39-NG imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Regency F39-NG ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Regency F39-NG, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Regency F39-NG.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Regency F39-NG. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Regency F39-NG insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.