Manuale d’uso / di manutenzione del prodotto F37-LPG del fabbricante Regency
Vai alla pagina of 28
05/18/06 Freestanding Gas Stove FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appli- ance Do not touch any electri- cal switch: do not use any phone in your building. Immediately call your gas supplier from a neighbour's phone.
2 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Regency ® Rear Flued Room Sealed Freestanding Gas Stove by FPI Fireplace Products International.
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 3 T ABLE OF CONTENTS D ATA B A D G E Data Badge ................................................................. 4 INST ALLA TION Important ................................................
4 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater This is a copy of the label that accompanies each REGENCY Rear Flued Room Sealed Freestanding Gas Stove. We have printed a D ATA B A D G E copy of the contents here for your review . The data plate is located on the inside of the drop down pedestal door .
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 5 INST ALLA TION AND REP AIRS SHOULD BE DONE BY AN AU- THORIZED SERVICE PERSON. THIS APPLIANCE SHOULD BE INST ALLED, REP AIRED, IN- SPECTED BEFORE USE AND A T LEAST ANNUALL Y BY AN AUTHORIZED SERVICE PERSON.
6 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater Make it a practice to have all of your gas appliances checked annually . 13) Do not slam shut or strike the glass door . 14) Under no circumstances should any solid fuels (wood, paper , cardboard, coal, etc.
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 7 INST ALLA TION EXTERIOR FLUE TERMINA TION LOCA TIONS Minimum clearances required for balanced fl ue terminals or the fl ue terminals o.
8 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater PLANNING YOUR FLUEING INST ALLA TION INST ALLA TION FLUEING The Regency ® Room Sealed System (Horizon- tal T ermination Kit (946-1 12) .
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 9 INST ALLA TION FLUEING ARRANGEMENTS - VERTICAL TERMINA TIONS for both Residential & Manufactured Homes/Mobile Homes Offset to V ertical T erminations If connecting to a Dura-V ent system, the Adapter to Dura-V ent # 640-994 is required.
10 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater INST ALLA TION Diagram 2 HORIZONT AL INST ALLA TIONS Diagram 1 *Diagram 2: Local codes or regulations may require different clearances.
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 11 Diagram 5 Diagram 4 Below Grade Snorkel Installation If the Snorkel T ermination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the Snorkel T ermination.
12 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater System Data - F37 Burner Inlet Orifi ce Sizes: NG LPG Burner #37 #52 Max. Input Rating 31.7 mj Min. Input Rating 16 mj Supply Pressure NG min. 1.13kPa LPG min. 2.75kPa Manifold Pressure NG .
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 13 INST ALLA TION CONVERSION KIT #731-968 FROM NG T O LPG USING SIT 820 NOV A GAS V AL VE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! W ARNING! Do not over tighten the screw .
14 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater INST ALLA TION C)02-44 AERA TION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply , air supply or altitude.
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 15 Diagram 2 Diagram 3 4) The latches should already be at the proper setting. If they are too hard or too easy to close, you may want to adjust them by loosening the locking nut and turning the latch catch.
16 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater INST ALLA TION OPTIONAL W ALL THERMOST A T A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve.
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 17 W ARNING: Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
18 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock.
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 19 COPY OF THE LIGHTING PLA TE INSTRUCTIONS OPERA TING INSTRUCTIONS 1 ) Push in the gas control knob slightly and turn clockwise t o OFF.
20 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater MAINTENANCE P ART OF CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER W A TER. CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV - ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERA T - ING THE APPLIANCE.
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 21 LA TCH ADJUSTMENT The door latch may require adjustment as the door gasket material compresses after a few fi res and after glass replacement. T urn the handle on the adjustable catch to tighten or loosen the latch.
22 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater MAINTENANCE REMOVING V AL VE If your valve requires maintenance or replace- ment, use the following instructions: Note: Alw ays close off the gas supply before removing the valve. 1) Open front pedestal door .
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 23 4) Remove the two outside frame pieces by removing two screws per side. See diagram below . 5 ) At this point you should disconnect the gas at the valve. Y ou can access it through the front now that the control panel is off, or you can access it through the rear pedestal cover plate.
24 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater P ARTS LIST 560-921 Louvre Assy (Set) - Nickel 1) 560-920 Louvre Assy (Set) - Gold 560-922 Louvre Assy (Set) - Black 4) 750-532 Door Sc.
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 25 52 60 68 67 68 66 90 92 95 96 98 97 93 94 91 89 69 71 82 83 54 55 57 78 56 BURNER & LOG ASSEMBL Y 52) 910-190 Piezo Ignitor & N.
26 F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater DOOR ASSEMBLIES Part # Description P ARTS LIST 730-923 Brush Nickel Mitred Door - Complete 730-924 Gold Mitred Door - Complete 730-926 .
F37 Regency ® Rear Flued Room Sealed Freestanding Gas Heater 27 WA R R A N T Y Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam care fully inspects each unit thoroughly before it leaves our door .
Printed in Canada © Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved..
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Regency F37-LPG è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Regency F37-LPG - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Regency F37-LPG imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Regency F37-LPG ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Regency F37-LPG, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Regency F37-LPG.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Regency F37-LPG. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Regency F37-LPG insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.