INST ALLA TION & OPERA TING INSTR UCTIONS SWIMMING POOL & SP A HEA TER D-2 Catalog No. 6000.57.1D Effective: 05-21-10 Replaces: 10-26-06 P/N 241243 Rev . 3 W ARNING: If these instructions are not followed exactly , a fire or explosion may result causing property damage, personal injury or death.
2 Rev . 3 reflects the following: Changes to: Parts photos on page 3, dimensional illustration on page 4, Fig. 1 and Fig. 3 on page 5, Illustrated Parts List on page 19.
3 RECEIVING EQUIPMENT On receipt of your equipment, it is suggested that you visually check for external damage to the carton. If the carton is damaged, it is suggested that a note be made on the Bill of Lading when signing for equipment. Remove the complete assembly from the carton.
4 INST ALLA TION REQUIREMENTS Failure to install, maintain and/or operate the Power V ent in accordance with manufacturer ʼ s instructions may result in conditions which can produce bodily injury and property damage.
5 INST ALLA TION 1 . Start off by disconnecting main power to the heater . 2. Remove the front door from the heater . See Fig 1. 3. If this is a retro-fit application, remove existing “Pagoda T op” and discard. See Fig. 2. If equipped with a drafthood, refer to drafthood installation manual for removal process.
6 INST ALLA TION (Continued) 6 . Lower the jacket top back onto the heater and reinstall the (6) Phillips screws. See Fig. 3. 7. If installing on a model 266, 267, 406 or 407 heater , skip step 8. 8. T urn t he Po wer V ent u psi de do wn . Usi ng a 5/ 16” n ut dr iv er , re loc ate t he mo un tin g bra cke ts as s ho wn in F ig.
7 INST ALLA TION (Continued) 1 3. Install the right side outdoor conduit through the top 7/8” hole located on the right side of the heater . See. Fig.
8 INST ALLA TION (Continued) 1 9. Route the 24 V AC harness through the 7/8” grommet, See Fig. 17. 20. Continue to route the harness down through any available grommet hole. See Fig. 18. 21. Wire the harness along with the installed gas valve harness per the wiring diagram.
9 U.S. Ins tallations 1 Canad ian Inst alla tions 2 A Clear ance above gr ade , veranda, p orch , deck, or balco ny 1 ft (30 c m) 1 ft (30 c m) B Clear ance to window or do or that may b e o pened 4 ft (1.
10 VENTING (Continued).
11 VENTING (Continued).
12 VENTING (Continued).
13 VENTING (Continued).
14 SEQUENCE OF OPERA TION On call for heat, the PC board will go through its safety chain (water pressure switch, high limit 1 & 2, roll-out, etc.). When the safety chain is closed, the IID pilot will begin to spark and the pilot gas valve will open.
15 WIRING (Continued) STEP 1 : VERIFY CURRENT CONNECTIONS AS SHOWN BELOW . P/PV C/ M/MV MV PV R/BK Y/BK Y/BK V/BK V/BK V/BK Y/BK G/BK P4 1 RELA Y D-2 POWER VENT Y/BK HONEYWELL V AL VE Y/BK V/W V/BK HONEYWELL V AL VE PV MV M /MV C/ P/PV STEP 2 : DISCONNECT BOTH TERMINALS MVPV & MV AS SHOWN BELOW .
16 WIRING (Continued) MODELS 206, 266, 336, 406 EQUIPPED WITH HONEYWELL GAS V A LV E V/W V/BK V/BK G/BK R/BK 1 P4 D -2 POWER VENT P/PV C/ M/MV MV PV HONEYWELL V AL VE STEP 4 : CONNECT THE MAIN V AL VE LINE, FEMALE SP ADE TO MALE SP ADE AS SHOWN BELOW .
17 WIRING DIAGRAM – MODELS 207A, 267A, 337A, 407A POWER VENT D-2 D-2 BLOWER POWER VENT GAS V AL VE HONEYWELL 1 1 + -.
18 WIRING DIAGRAM – MODELS 206A, 266A, 336A, 406A POWER VENT D-2 D-2 BLOWER POWER VENT + - 1 1 TH TR.
19 REPLACEMENT P ARTS NOTE: T o supply you with the correct part, it is impor- tant that you supply the heater model number , serial number and type of gas when applicable.
20 w w w .r ay pak .co m Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468 Litho in U.S.A..
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Raypak D-2 POWER VENT 206A è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Raypak D-2 POWER VENT 206A - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Raypak D-2 POWER VENT 206A imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Raypak D-2 POWER VENT 206A ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Raypak D-2 POWER VENT 206A, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Raypak D-2 POWER VENT 206A.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Raypak D-2 POWER VENT 206A. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Raypak D-2 POWER VENT 206A insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.