Manuale d’uso / di manutenzione del prodotto AMC-101 del fabbricante RAD Data comm
Vai alla pagina of 65
AMC-101 Universal Media Converter and Repeater Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications. No part of this publicatio n may be rep roduced in any for m whatsoever w ithout prio r written ap proval by RAD Data Communications.
.
Warranty This RAD produ ct is warranted agains t defects in ma terial and workmanshi p for a period of one y ear from date of shipme nt. Duri ng the warranty period, RAD wi ll, at its option, either repai r or replace products which prove to be defective.
Safety Warnings The exc lamation point within a triangl e is intended to warn th e operator or service personnel of operati on and maintenance f actors relating to the product and i ts operating environment which could pose a safety hazard.
Regulatory Information FCC-15 User Information This equipment has b een tested and found to comply with the limits of the Class A digital device, pursuant to Part 1 5 of the FCC rules . Thes e limits are desi gned to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Declaration of Conformity Manufacturer’s Name: RAD Data Communications Ltd. Manufacturer’s Address: 12 Hanechoshet St. Tel Aviv 69710 Israel declares that the product: Product Name: AMC-101 Confor.
AMC-101 Installation and Operation Manual i Contents CHAPTER 1 – INTRODUC TION 1.1 General .................................................................................................................... ......................... 1-1 Retimed Mo dules .
Contents ii AMC-101 Installation and Operation Manual SM/ST/13LH/ R Modul e ............................................................................................................ ........... 2-15 SM/FC/13LH/ R Mod ule............................
Contents AMC-101 Installation and Operation Manual iii List of Figures Figure 1-1 Dissimilar Devic e Con nectivity .................................................................................... .............. 1-3 Figure 1-2 Dual Simila r Device Co nnec tivity .
List of Tables iv AMC-101 Installation and Operation Manual Figure 2-36 10BT/ B Mod ule Fron t Panel........................................................................................ ........... 2-35 Figure 3-1 AMC -101 Front Pane l ............
General 1-1 Chapter 1 Introduction 1.1 General The AMC-101, a Universal Converter and Repeater, provides retimed or transparent conversion of optical and electrical signals for ATM, FDDI, Fast Ethernet and other protocols at data rates up to 155 Mbps.
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-2 Features 1.2 Features Modular Media Converter and Repeater, Media types supported: • Single Mode Fiber • Multimode Fiber • STP • UTP • Coax Retimed media conversion for 51 Mbps, 100 Mbps and 155 Mbps.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction General Applications 1-3 1.3 General Applications A single AMC-101 is used to connect two devices operating with different fiber or electrical interfaces (see Figure 1-1 ).
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-4 General Applications A single AMC-101 in WRAP mode can be used for double conversion between single mode and multimode fiber for a dual attached FDDI station or concentrator (see Figure 1-3 ).
AMC-101 Installation & Operation Manual Chapter 1 - Introduction General Applications 1-5 The FDDI applies scrambling to data when operating over UTP, but not doing so when operating over fiber. Because of this, AMC-101 can only work in pairs for extending FDDI connections over fiber (see Figure 1-5 ).
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-6 Fast Ethernet Applications 1.4 Fast Ethernet Applications • Point to Point Link using a pair of Fiber Optic Cables running in HD (Half Duplex) 100-BaseFX: Problem: In a point to point application, in HD, the maximum range is limited to 412m .
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Fast Ethernet Applications 1-7 • Repeater based LAN Link using standard UTP at HD (Half Duplex).
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-8 Fast Ethernet Applications • Extension of a point to point FD (Full Duplex) Fast Ethernet connection: Problem: The distance between two FD stations running on UTP needs to be extended.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Specifications 1-9 • Extension of a Switched Based Fast Ethernet LAN (FD - Full Duplex) Problem: The range of a FD Fast Ethernet LAN running on UTP has to be extended.
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-10 Specifications 1.5 Specifications Data Rate Up to 155 Mbps Indicators POWER (PWR) ON when unit is powered FAULT (FLT) BLINKS w.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Specifications 1-11 Table 1-1 Optical Module Characteristics Module Name Protocols Supported Fiber Type (Wavelength) Connector Type Typical Distance Dynamic Range Optical Power (Typical) Sensitivity MM/ST/85* Token Ring, Ethernet only 62.
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-12 Specifications Table 1-1 Optical Module Characteristics (Cont.) Module Name Protocols Supported Fiber Type (Wavelength) Connec.
AMC-101 Installation & Operation Manual Chapter 1 - Introduction Specifications 1-13 Table 1-2 Electrical Module Characteristics Module Name Protocols Supported Cable Type Connector Type Range Imp.
Chapter 1 - Introduction AMC-101 Installation & Operation Manual 1-14 Specifications.
Site Requirements 2-1 Chapter 2 Installation & Setup 2.1 Unpacking Before Unpacking Inspect the equipment container before unpacking. Note and report evidence of damage immediately. Unpacking Procedure • Place the container on a clean flat surface .
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-2 Site Requirements Figure 2-1 AMC-101 Rear Panel AC Version Figure 2-2 AMC-101 Rear Panel DC Version Installation of a Single Unit Rack adapter components for installing a single unit include one short bracket and one long bracket.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup Site Requirements 2-3 Installation of Two Units Rack adapter components for installing two units include two long side .
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-4 AMC-101 Modules Figure 2-5 Installation of Two Units (b) 2.3 Cable Connections AC Power Connection AC power should be supplied to AMC-101 through a 1.5m (5 ft) standard power cord terminated by a grounded 3-wire plug.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-5 2.4 AMC-101 Modules The upper part of t he module front panel i s AMC-R for a R eti med Timing mode; the lower part is AMC-T for a Transparent Timing mode.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-6 AMC-101 Modules MM/SC/13/T Module Figure 2-7 MM/SC/13/T Module Front Panel Wavelength: 1300 nm Connector: SC Used w.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-7 MM/ST/13/R Module Figure 2-8 MM/ST/13/R Module Front Panel Wavelength: 1300 nm Connector: ST Used w.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-8 AMC-101 Modules MM/ST/13/T Module Figure 2-9 MM/ST/13/T Module Front Panel Wavelength: 1300 nm Connector: ST Used w.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-9 SM/ST/13/R Module Figure 2-10 SM/ST/13/R Module Front Panel Wavelength: 1300 nm Connector: ST Used .
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-10 AMC-101 Modules SM/ST/13/T Module Figure 2-11 SM/ST/13/T Module Front Panel Wavelength: 1300 nm Connector: ST Used.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-11 SM/FC/13/T Module Figure 2-12 SM/FC/13/T Module Front Panel Wavelength: 1300 nm Connector: FC Used.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-12 AMC-101 Modules SM/ST/13L/R Module Figure 2-13 SM/ST/13L/R Module Front Panel Wavelength: 1300 nm Connector: ST Us.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-13 SM/ST/13L/T Module Figure 2-14 SM/ST/13L/T Module Front Panel Wavelength: 1300 nm Connector: ST Us.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-14 AMC-101 Modules SM/SC/13L/R Module Figure 2-15 SM/SC/13L/R Module Front Panel Wavelength: 1300 nm Connector: SC Us.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-15 SM/ST/13LH/R Module Figure 2-16 SM/ST/13LH/R Module Front Panel Wavelength: 1300 nm Connector: ST .
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-16 AMC-101 Modules SM/FC/13LH/R Module Figure 2-17 SM/FC/13LH/R Module Front Panel Wavelength: 1300 nm Connector: FC .
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-17 SM/ST/15L/R Module Figure 2-18 SM/ST/15L/R Module Front Panel Wavelength: 1550 nm Connector: ST Us.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-18 AMC-101 Modules SM/ST/15LH/R Module Figure 2-19 SM/ST/15LH/R Module Front Panel Wavelength: 1550 nm Connector: ST .
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-19 SM/FC/15LH/R Module Figure 2-20 SM/FC/15LH/R Module Front Panel Wavelength: 1550 nm Connector: FC .
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-20 AMC-101 Modules MM/ST/85/T Module Figure 2-21 MM/ST/85/T Module Front Panel Wavelength: 850 nm Connector: ST Used .
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-21 SF1/ST/R Module Figure 2-22 SF1/ST/R Module Front Panel Wavelength: Transmit: 1300 nm; Receive: 15.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-22 AMC-101 Modules SF2/ST/R Module Figure 2-23 SF2/ST/R Module Front Panel Wavelength: Transmit: 1550 nm; Receice: 13.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-23 SF1/FC/R Module Figure 2-24 SF1/FC/R Module Front Panel Wavelength: Transmit: 1300 nm; Receive: 15.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-24 AMC-101 Modules SF2/FC/R Module Figure 2-25 SF2/FC/R Module Front Panel Wavelength: Transmit: 1550 nm; Receive: 13.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-25 CX/BNC/155/R Module Figure 2-26 CX/BNC/155/R Module Front Panel Connector: BNC Used with: Coax cable Protocols supported: STS-3c, STM-1 Timing mode: Retimed Range calculation: 12.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-26 AMC-101 Modules CX/DIN/155/R Module Figure 2-27 CX/DIN/155/R Module Front Panel Connector: 1.6/5.6 Coax Used with: Coax cable Protocols supported: STS-3c, STM-1 Timing mode: Retimed Range calculation: 12.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-27 STP/155/R Module Figure 2-28 STP/155/R Module Front Panel Connector: DB-9 Used with: STP type 1 ca.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-28 AMC-101 Modules STP/155/T Module Figure 2-29 STP/155/T Module Front Panel Connector: DB-9 Used with: STP type 1 ca.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-29 UTP/155/R Module Figure 2-30 UTP/155/R Module Front Panel Connector: Shielded RJ-45 Used with: UTP.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-30 AMC-101 Modules UTP/155/T Module Figure 2-31 UTP/155/T Module Front Panel Connector: Shielded RJ-45 Used with: UTP.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-31 UTP/100/R Module Figure 2-32 UTP/100/R Module Front Panel Connector: Shielded RJ-45 Used with: UTP.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-32 AMC-101 Modules UTP/100/T Module Figure 2-33 UTP/100/T Module Front Panel Connector: Shielded RJ-45 Used with: UTP.
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-33 100BT/B Module AMC-B 100BTX TX RX LINK COLL Figure 2-34 100BT/B Module Front Panel Connector: Shie.
Chapter 2 - Installation & Setup AMC-101 Installation & Operation Manual 2-34 AMC-101 Modules 100BT/R Module AMC-R 100BTX TX RX LINK Figure 2-35 100BT/R Module Front Panel Connector: Shielded .
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup AMC-101 Modules 2-35 10BT/B Module AMC-B 10BT TX RX LINK COLL Figure 2-36 10BT/B Module Front Panel Connector: Shielded.
Controls and Indicators 3-1 Chapter 3 Operation 3.1 Controls and Indicators All controls and indicators are located on the front panel of AMC-101. PWR FL T WRAP OTHER 155 100 51 AMC-R AM C-R SIG SIG T.
Chapter 3 - Operation AMC-101 Installation & Operation Manual 3-2 Controls and Indicators Po wer Su pp ly AC DB-9 Conne cto r (AL ARM ) JP 2 JP 1 AMC-RELA Y (AL ARM ) Card JP 1 JP 4 JP 2 GN D JP 6.
AMC-101 Installation & Operation Manual Chapter 3 - Operation Dry Contact Circuit and Connector for Alarms 3-3 3.2 Cable Connections Grounding DC adapter Connection. Note In order to protect the AMC-1 from electrostatic discharge (ESD), use a DC adapter where the (-) DC pole is connected to the protective earth.
Chapter 3 - Operation AMC-101 Installation & Operation Manual 3-4 Turning on the AMC-101 Example: For the RED ALARM the common input (COM) pin is 9. If there is no power failure, it connects to pin 4 (OK). If there is a failure, pin 9 connects to pin 5 (FAIL).
AMC-101 Installation & Operation Manual Chapter 3 - Operation Turning on the AMC-101 3-5 PWR LED FL T LED WRA P LE D WRAP Butto n 51 100 155 Ot her RA TE Switc h Cont ro l Logi c Rela y 1 Dry Co n.
Chapter 3 - Operation AMC-101 Installation & Operation Manual 3-6 Troubleshooting Procedures 3.5 Normal Operation Once powered on, the POWER indicator should light up and the FLT should be turned off. If the FLT indicator blinks, a configuration error exists: the combination of the card types and the selected data rate is illegal.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il RAD Data comm AMC-101 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del RAD Data comm AMC-101 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso RAD Data comm AMC-101 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul RAD Data comm AMC-101 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il RAD Data comm AMC-101, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del RAD Data comm AMC-101.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il RAD Data comm AMC-101. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo RAD Data comm AMC-101 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.