Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 1 Model: QVI-30FB In the Commonwealth of Massachusetts: • installation must be performed by a licensed plumber or gas fitter; See T able of Contents for location of additional Commonwealth of Massachusetts requirements.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide .
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 3 TABLE OF CONTENTS Safety and W arning Information ................................................ 2 Service Parts Lists ..................................................................... 4 Section 1: Approvals and Codes .
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 4 4 1 6 2 7 3 5 8 9 10 11 13 14 15 16 17 19 20 18 12 Part number list on following page. Log Set Assembly Service Parts Diagram Service Parts QVI.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 5 Service Parts List QVI-30FB Î I TEM DES CRIP TI O N S ERIAL # P ART NUM BER Log S et A s s em bly LO G S- Q V I 30F B Y 1 Log 1 S R V 2020-140.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 6 V alve Assembly Part s Diagram Service Parts QVI-30FB 6 7 8 9 10 1 2 5 4 3 IT E M D E SC R IPTIO N SE R IA L # PA R T N U MB E R 1 Fl ex B al l.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 7 Appliance Certification The Quadra-Fire appliance discussed in this Installers Guide has been tested to certification standards and listed by the applicable laboratories.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 8 NOTE: The following requirements reference various Massachusetts and national codes not contained in this document.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 9 2 Getting St arted Introducing the Quadra-Fire Gas Appliances Quadra-Fire direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 10 QVI -3 0 F B MI N I MU M F IR E P L AC E S IZE Lo cation I n ches Mi llimeters A F ron t Wi dth 30-1/ 4 768 B R ear Width 19 483 C D epth 14-1.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 11 Q VI -3 0FB M O DEL DI M ENSI O NS Locat i on Inches M illimete rs A 18 457 B6 - 1 / 2 1 6 5 C 29-3/ 8 746. 1 D 26-1/ 1 6 661 E 20-5/ 8 524 F 14-5/ 8 371 G 22-1/ 8 562 H 21-1/ 4 540 Dimensions in brackets are millimeters.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 12 3 Inst alling the Insert Step 1. Inst alling the V ent System V ent System Inst allation Precautions Before starting installation of vent kits, the installer should read these instructions and the V ent Kit Instructions to ensure that a proper vent installation is completed.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 13 ! Attach the flashing and termination cap to the top of the flexible vent pipe and set the cap in place.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 14 Figure 4. This option shows both exhaust and inlet air vent pipes attached to the adaptor. W ARNING: THE EXHAUST VENT PIPE MUST ONL Y BE CONNECTED TO THE EXHAUST ST ARTING COLLAR OF THE UNIT AND THE CENTER COLLAR OF THE TERMINA TION CAP .
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 15 Figure 5. T ypical configuration of vent liners. Note: Inspect for exhaust collar gasket to insure positive exhaust seal.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 16 Step 2. Positioning, Leveling, and Securing the Insert • Place the insert into position. • Level the insert from side to side and from front to back. Use the leveling legs if necessary to set each corner of the base.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 17 Step 5. Gas Pressure Requirements Pressure requirements for these gas appliances are shown in the table below . Pressure Natural Gas Propane Minimum 5.0 inches 1 1.0 inches Inlet Pressure w .c.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 18 Serving the blower On units already installed removal of decorative front, sur- round and gas insert is required. • Detach flexible liner from the top of unit. • Remove the four screws on the coverplate (see Figure 1 1).
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 19 Step 7. Installing Logs and Ember Material Positioning the Logs The logs have been packaged sep arately . Refer to the installation instructions that accompany this manual. Save the log instructions with this manual.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 20 Step 9. Before Lighting the Appliance Before lighting the appliance, be sure to do the following: Remove all paperwork from the fireplace. Review safety warnings and cautions • Read the Safety and Warning Information section at the beginning of this Installers Guide .
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 21 Step 10. Lighting the Appliance ST ANDING PILOT IGNITION A . This appliance (standing pilot version) has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactly .
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 22 4 Maint aining and Servicing Y our Appliance Appliance Maintenance Although the frequency of servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an appliance check- up at the beginning of each heating season.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 23 T roubleshooting With proper installation, operation, and maintenance your gas fireplace will provide years of trouble-free service.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 24 Sym pto m P ossible Cause C orrect ive A cti on 4. Fr equ en t pi lot ou t age probl em. a. P i lot f lam e may be too h i gh or t oo low , or bl owin g (h i gh ), cau si n g pi l ot saf ety to dr op ou t .
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 25 Lifet ime Warrant y LIMITED LIFETIME W ARRANTY The Hearth & Home T echnologies limited Lifetime Warranty guarantees that the following component s will work as designed for the lifetime of the stove or Hearth & Home T echnologies will repair or replace them.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Quadra-Fire QVI-30FB è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Quadra-Fire QVI-30FB - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Quadra-Fire QVI-30FB imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Quadra-Fire QVI-30FB ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Quadra-Fire QVI-30FB, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Quadra-Fire QVI-30FB.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Quadra-Fire QVI-30FB. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Quadra-Fire QVI-30FB insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.