Manuale d’uso / di manutenzione del prodotto CASTILEI-CE-MBK del fabbricante Quadra-Fire
Vai alla pagina of 36
R www .quadrare.com October 27, 201 1 CASTILE & SANT A FE PELLET INSERT Owner ’ s Manual Installation and Operation CASTILEI-CE-MBK SANT AFEI-CE-MBK Models: DO NOT DISCARD THIS MANUAL NOTICE • Important operating and maintenance instruc - tionsincluded.
Page2 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B and Welcome to the Quadra-Fire Family ! Hearth & Home T echnologies welcomes you to our tradition.
R October 27, 201 1 Page3 Castile & Santa Fe CE Insert 7069-101B T ABLE OF CONTENTS Safety Alert Key: • DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwillresultindeathorseriousinjury .
Page4 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B.
R October 27, 201 1 Page5 Castile & Santa Fe CE Insert 7069-101B.
Page6 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B A. Appliance Certication B. Glass Specications D. Specications This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass.
R October 27, 201 1 Page7 Castile & Santa Fe CE Insert 7069-101B HOT SURF ACES! Glassandothersurfacesarehotduringoperation ANDcooldown.
Page8 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B A. Fire Safety T o provide reasonable re safety , the following should be givenseriousconsideration: • Install at least one smoke detector and CO monitor on each oorofyourhome.
R October 27, 201 1 Page9 Castile & Santa Fe CE Insert 7069-101B D. General Operating Information 1. Thermostat Calls For Heat The appliance is like most modern furnaces; when the thermostat callsfor heat,your appliancewill automaticallylight anddeliver heat.
Page10 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B H. Fire Characteristics A properly adjusted re with the heat output control button seton“HIGH”hasashort activeamepatternthatextends outoftherepotapproximately102mm.
R October 27, 201 1 Page1 1 Castile & Santa Fe CE Insert 7069-101B J. Ignition Cycles 1. At the beginningof eachignition cycle, itis normalto see some smoke in the rebox. The smoke will stop once therestarts.
Page12 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B 3 Maintaining & Servicing Y our Appliance C. General Maintenance 1. T ypes of Fuel Depending on the type of fuel you are burning will dictate how oftenyouhavetocleanyourrepot.
R October 27, 201 1 Page13 Castile & Santa Fe CE Insert 7069-101B 5. Disposal of Ashes • Frequency: Asneeded • By: Homeowner Ashes should be placed in a metal container with a tight-tting lid.
Page14 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B The amount of ash buildup in the repot will be a good guide to determine how often you should clean the heat exchangers.
R October 27, 201 1 Page15 Castile & Santa Fe CE Insert 7069-101B 12. Cleaning Combustion Blower - Requires No Lubrication • Frequency: Y earlyorasneeded • By: QualiedServiceT echnician • T ask: Contact your local dealer 13.
Page16 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B D. High Ash Fuel Content Maintenance • Frequency: Asneeded • By: Homeowner Correct Flame Size, Y ellow/White in Color Correct Figure 16.
R October 27, 201 1 Page17 Castile & Santa Fe CE Insert 7069-101B NOTICE: Odors and vapors are released during initial operation due to the curing of high tem - peraturepaint.Openwindowsforaircirculation.
Page18 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B 5 Getting Started Installer ’ s Guide A . Design, Installation & Location Considerations W ARNING! Risk of Fire Damaged parts could impair safe operation.
R October 27, 201 1 Page19 Castile & Santa Fe CE Insert 7069-101B B. Thermostat Location The thermostat’s location will have some effect on the appliance’soperation.
Page20 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B 6 Dimensions and Clearances A. A ppliance Dimensions Figure 20.3- Front View Figure 20.
R October 27, 201 1 Page21 Castile & Santa Fe CE Insert 7069-101B Figure 20.4 - T op View A B C D C. Minimum Opening for Masonry and Factory-Built Fireplaces Inches Millimeters A Insertsidetocombustiblesidewall 16 406 B Inserttoptomantel 12 305 C Inserttoptomaximum.
Page22 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B Do not terminate vent inanyenclosedorsemi-enclosed areasuchasacarport,garage,attic,cr.
R October 27, 201 1 Page23 Castile & Santa Fe CE Insert 7069-101B V ent Congurations T oreduce probability ofreverse drafting duringshut-down conditions Hearth.
Page24 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B E. Chimney and Exhaust Connection 1. Chimney & Connector :Use76mmto102mmdiameter type "L" or "PL" venting system. It can be vented vertically orhorizontally .
R October 27, 201 1 Page25 Castile & Santa Fe CE Insert 7069-101B F. P ellet V enting Charts FireRisk. • Only LISTED venting components may be used. • NOOTHER ventcomponentsmaybe used. Substituteordamagedventcomponentsmay impairsafeoperation.
Page26 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B 8 V enting Systems Figure 28.1 CAUTION Neverdrawoutsidecombustionairfrom: • W all,oororceili.
R October 27, 201 1 Page27 Castile & Santa Fe CE Insert 7069-101B B. Full Reline With V ertical Outside Air Figure 29.1 Outside Air T ermination at Chimney T op 12” (305mm) min. below 12” (305mm) min. above NOTE; Use metal plate around exhaust vent pipe and seal all edges with non-flammable insulation such as mineral wool or ceramic.
Page28 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B 9 Appliance Set-Up A. Leveling System B. Outside Air Kit Instructions Parts Included in Kit: 1pieceof51mmx.
R October 27, 201 1 Page29 Castile & Santa Fe CE Insert 7069-101B C. Door Handle Removal 1. Opentheouterdoor . 2. Unlatchandopenthereboxdoor . 3. Continue to turn handle until it is free from the rebox door .
Page30 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B Figure 32.2 1 2 3 4 5 6 7 8 F . Hearth Support For Standard Surround Only Figure 33.
R October 27, 201 1 Page31 Castile & Santa Fe CE Insert 7069-101B Base Plate Only Installation Parts Needed :(1)castring(2)basezeroclearancepanel extensions.Discardbalanceofparts. T ools Needed: Phillipsheadscrewdriver 1.
Page32 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B H. Surround and Cast T rim Set (CASTILE INSERT) I ncluded in Surround Kit: (2)sidesurrounds,leftand right;(1)surroundtop;(1)fastenerpackage.
R October 27, 201 1 Page33 Castile & Santa Fe CE Insert 7069-101B I. Panel and T rim Set (SANT A FE INSERT) 1. Laypanel topand legs facedown onprotective cov - eringtopreventscratching. 1. Attachthe panellegs tothe toppanel usinga Phillips head screwdriver .
Page34 October 27, 201 1 R Castile & Santa Fe CE Insert 7069-101B 1. Opendoortoexposetherebox. 2. Install the left log rst and then the right log. Figure 37.1 3. Lean the logs against the cast iron brick in the back of therebox.
R October 27, 201 1 Page35 Castile & Santa Fe CE Insert 7069-101B 1 . A 12 volt ACthermostat is required to operate this pellet appliance.
Page36 R Hearth & Home T echnologies 1445 North Highway Colville, W A 991 14 Division of HNI CORPORA TION www .quadrare.com CONT ACT INFORMA TION : Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer visit our website at www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Quadra-Fire CASTILEI-CE-MBK è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Quadra-Fire CASTILEI-CE-MBK - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Quadra-Fire CASTILEI-CE-MBK imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Quadra-Fire CASTILEI-CE-MBK ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Quadra-Fire CASTILEI-CE-MBK, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Quadra-Fire CASTILEI-CE-MBK.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Quadra-Fire CASTILEI-CE-MBK. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Quadra-Fire CASTILEI-CE-MBK insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.