R www .quadra fi re.com 7033-277C March 2, 2007 T ested and List ed by Beaverton Oregon US A OMNI- Test Laborator i es, Inc. C US DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation.
Page 2 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) Hearth & Home T echnologies welcomes you to our tradi- tion of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durabil- ity , and performance.
March 2, 2007 7033-277C Page 3 3100 Wood Stove Series (ACC) R Section 1: Listing and Code Approvals A. Appliance Certi fi cations ...................... 4 B. Mobile Home Approved ...................... 4 C. Glass Speci fi cations ...................
Page 4 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) 1 Listing and Code Approvals The Quadra-Fire 3100 Series Wood Stove (ACC) meets the U.S. Environmental Protection Agency’s 1990 particulate emission standards. A. Appliance Certi fi cation C.
March 2, 2007 7033-277C Page 5 3100 Wood Stove Series (ACC) R 2 Getting Started A . Design, Installation & Location Consider ations Consideration must be given to: • Safety • Convenience • T.
Page 6 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) Recommended Location Marginal Location Location Not Recommended Recommended Location Location NOT Recommended Multi-level Roofs Windward Leeward Outside T ermination Cap Figure 6.1 C. Negative Pressure Draft is the pressure difference needed to vent appliances successfully .
March 2, 2007 7033-277C Page 7 3100 Wood Stove Series (ACC) R Exterior conditions such as roof line, surrounding trees, prevailing winds and nearby hills can influence stove performance. Y our local dealer is the expert in your geographic area and can usually make suggestions or discover solutions that will easily correct your fl ue problem.
Page 8 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) Flo or Protector Chi mne y Connector Ins ul ated " T " Flas hing Li st ed T er mi n a tio n C a p Tr i m C o l l a r o n Insid e.
March 2, 2007 7033-277C Page 9 3100 Wood Stove Series (ACC) R 3 Dimensions and Clearances 26-1 1/16 in. (668mm) 24-5/16 in. (618mm) 6-1 1/16 in. (170mm) 16 in. (406mm) 11 - 1 / 2 i n . (292mm) 20-3/4 in. (527mm) C L A. Appliance Dimensions Figure 9.1 Front View Figure 9.
Page 10 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) Appliance Dimensions (Cont’d) Figure 10.1 Figure 10.2 Figure 10.3 Figure 10.4 3100 Step Top Pedestal Model 3100 Step Top Leg Model 23-7/8 in. (606mm) 33-1/8 in. (841mm) 15-1/16 in. (383mm) 19-1/16 in.
March 2, 2007 7033-277C Page 1 1 3100 Wood Stove Series (ACC) R B. Clearances to Combustibles (UL and ULC) BACKW ALL / SIDEW ALL A B C D E F E F CORNER INST ALLA TION G G H * 90° OFF TOP UP & OUT.
Page 12 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) A. Hearth Protection Requirements FLOOR PROTECTION: Floor protector must be non-com- bustible material, extending beneath heater and to the front, sides and rear as indicated.
March 2, 2007 7033-277C Page 13 3100 Wood Stove Series (ACC) R Must extend 2 i n. (51mm) beyond each side of pi pe (shaded area) NOTE: • Illustrations and photos re fl ect typical installations and are FOR DESIGN PURPOSES ONL Y . • I llustrations/diagrams are not drawn to scale.
Page 14 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) B. Outside Air Kit Installation 1. Remove all materials from packing box. 2. Using a #2 Phillips screw driver attach the fl ex adapter to the stove using 4 screws. Figure 14.1 3. Remove circular” knock-out” in the base of the pedestal.
March 2, 2007 7033-277C Page 15 3100 Wood Stove Series (ACC) R C. Blower (Optional) Do not remove . 1. Remove the 3 bolts (1/4”-20 Phillips head) on the outer skin at the bottom rear of appliance. 2. Align holes in mounting fl ange of blower with bolt holes in appliance.
Page 16 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) NOTE: I n Canada when using a factory-built chimney it must be safety listed, Type UL103 HT (2100 o F) CLASS “A” or conforming to CAN/ULC-S629M, STANDARD FOR 650 o C FACTORY-BUILT CHIMNEYS.
March 2, 2007 7033-277C Page 17 3100 Wood Stove Series (ACC) R Thimble Site constructed for masonry chimney installation: Components • A minimum length of 12 inches [305mm] (longer for thicker walls) of solid insulated factory-built chimney length constructed to UL 103 T ype HT 8 inch (203mm) inside diameter .
Page 18 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) Chimney Height / Rise and Run This product was designed for and tested on a 6 inch (152mm) chimney , 14 to 16 feet (420-480cm) high, (includes stove height) measured from the base of the appliance.
March 2, 2007 7033-277C Page 19 3100 Wood Stove Series (ACC) R D. Chimney T ermination Requirements Follow manufacturers instructions for clearance, securing, fl ashing and terminating the chimney .
Page 20 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) Figure 20.1 SparkArestor Cap Roof Flashing Storm Collar Joist Shield /Fire stop Doub le wall connector pipe Floor Protector Outs ide A ir Flo or V ent OutsideAi r Rear V ent CAUTION Maintain structural integrity of mobile home: • Floor , wall, ceiling and/or roof.
March 2, 2007 7033-277C Page 21 3100 Wood Stove Series (ACC) R 7 Appliance Set Up Figure 21.3 Do NOT operate before fully assembling components. Burning your stove without a pedestal or leg kit attached: • Will void your warranty . • May result in property damage or personal injury .
Page 22 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) Installing Pedestal Assembly 1. Remove screws on adapter and slide pedestal over adapter on bottom of stove. Figure 22.1. 2. Line up holes in sides of pedestal with holes in adapter . 3. Securely tighten pedestal into place.
March 2, 2007 7033-277C Page 23 3100 Wood Stove Series (ACC) R B. Leg Kit and Ash Removal Installation (ARS) for Step Top Uni-Body Do NOT tilt the unit on the cast iron legs. • Tilting could lead to property damage. • Lift the unit upright and place it into position on the fl oor protector .
Page 24 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) N OTE: When the speed control is turned clockwise, it will click on to high speed. Continue to turn the speed control clockwise to decrease the speed. At full clockwise, the blower should blow gently , but should not stop.
March 2, 2007 7033-277C Page 25 3100 Wood Stove Series (ACC) R 8 Operating Instructions B. Wood Selection & Storage Burn only dry seasoned wood. Store wood under cover , out of the rain and snow . Dry and well-seasoned wood will not only minimize the chance of creosote formation, but will give you the most ef fi cient fi re.
Page 26 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) 2. Second Stage The next stage of burning, the secondary stage, is the period when the wood gives off fl ammable gases which burn above the fuel with bright fl ames. During this stage of burning it is very important that the fl ames be maintained and not allowed to go out.
March 2, 2007 7033-277C Page 27 3100 Wood Stove Series (ACC) R F . Burn Rates and Operating Ef fi ciency For maximum operating ef fi ciency 1. This appliance has a timer system (ACC) that operates the stove at its maximum ef fi ciency removing any guess work for the homeowner .
Page 28 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) G. Building A Fire Before lighting your fi rst fi re in the stove: 1. Con fi rm the baf fl e is correctly positioned. It should be even with the front tube and resting on all tubes. Figure 28.
March 2, 2007 7033-277C Page 29 3100 Wood Stove Series (ACC) R I. Opacity (Smoke) This is the measure of how cleanly your appliance is burn- ing. Opacity is measured in percent; 100% opacity is when an object is totally obscured by the smoke column from a chimney , and 0% opacity means that no smoke column can be seen.
Page 30 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) K. Frequently Asked Questions ISSUES SOLUTIONS Odor from appliance When fi rst operated, this appliance may release an odor for the fi rst several hours. This is caused by the curing of the paint and the burning off of any oils remaining from manufacturing.
March 2, 2007 7033-277C Page 31 3100 Wood Stove Series (ACC) R 9 Maintaining & Servicing Y our Appliance A. General Maintenance Inspection: Inspect the system at the appliance connection and at the chimney top.
Page 32 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) 5. Cleaning Plated Surfaces • Frequency: As necessary • By: Homeowner • T ask: See the following instructions. Clean all the fi ngerprints and oils from plated surfaces BEFORE fi ring the appliance for the fi rst time.
March 2, 2007 7033-277C Page 33 3100 Wood Stove Series (ACC) R Replace the fi rebrick if they become crumbly and/or if there is a 1/4 inch (6.35mm) gap between the bricks. The fi rebox is lined with high quality fi rebrick, which has exceptional insulating properties.
Page 34 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) D. Baf fl e Removal 1. Remove all ash from the fi rebox, and extinguish all hot embers before disposal into a metal container .
March 2, 2007 7033-277C Page 35 3100 Wood Stove Series (ACC) R F . T ube Channel Assembly Replacement Removing Tube Channel Assembly 1. Remove the right side shield by removing 2 screws in the back using a Phillips head screw driver. 2. Remove 4 screws from channel access cover and remove cover.
Page 36 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) 10 T roubleshooting With proper installation, operation, and maintenance your woodstove will provide years of trouble-free service.
March 2, 2007 7033-277C Page 37 3100 Wood Stove Series (ACC) R 4. I don’t get enough/any heat. What can I do about it? Diagnostic Question Possible Causes of Condition Solutions How much wood is use.
Page 38 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) 11 Reference Materials Figure 38.1 - Door , Glass And Door Handle Assembly Beginning Manufacture Date: Millennium Model: July , 2006 Step T op Model: August, 2006 A. Exploded view Figure 38.
March 2, 2007 7033-277C Page 39 3100 Wood Stove Series (ACC) R 1 11 21 2 3 4 6 7 8 9 10 12 13 14 15 17 18 19 20 22 23 24 25 26 27 28 29 30 31 32 33 34 16 5 SIZES (#33) Baf fl e Board: 9-1/2” w x 13.
Page 40 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) Item Description Item Description 1 Oak Strip for Pedestal 23 Air Supply, Back 4 Knob, Start-Up Air Control 25 Panel Assembly , Side, Lef.
March 2, 2007 7033-277C Page 41 3100 Wood Stove Series (ACC) R IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on the Quadra- Fire web site at www .quadra fi re.com. When ordering, supply serial and model numbers to ensure correct service parts.
Page 42 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) Component Pack, Door, Black & Gold (includes Gold Spring Handles 1/2” & 1/4” 1 each, 2 Gold Hinge Pins, Quadra-Fire Logo 436-.
March 2, 2007 7033-277C Page 43 3100 Wood Stove Series (ACC) R Snap Disc, F125 F-20 230-0470 Snap Disc Cover Box 7033-261 14 Spring Handle, Burn Rate Control, 1/4”, Gold 832-0630 14 Spring Handle, B.
Page 44 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) Date of Service Performed By Description of Service C. Service And Maintenance Log.
March 2, 2007 7033-277C Page 45 3100 Wood Stove Series (ACC) R D. Homeowner ’ s Notes.
Page 46 7033-277C March 2, 2007 R 3100 Wood Stove Series (ACC) D. Homeowner ’ s Notes (Cont’d).
March 2, 2007 7033-277C Page 47 3100 Wood Stove Series (ACC) R Lifetime Warranty C. W arranty Policy LIMITED LIFETIME WARRANTY The Hearth & Home Technologies limited Lifetime Warranty guarantees that the following components will work as designed for the lifetime of the stove or Hearth & Home Technologies will repair or replace them.
R Hearth & Home T echnologies 1445 North Highway Colville, W A 991 14 Division of HNI INDUSTRIES 7033-277C March 2, 2007 Page 48 CONT ACT INFORMA TION : Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer , log onto www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Quadra-Fire 31ST-ACC è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Quadra-Fire 31ST-ACC - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Quadra-Fire 31ST-ACC imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Quadra-Fire 31ST-ACC ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Quadra-Fire 31ST-ACC, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Quadra-Fire 31ST-ACC.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Quadra-Fire 31ST-ACC. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Quadra-Fire 31ST-ACC insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.