Manuale d’uso / di manutenzione del prodotto 3100-I del fabbricante Quadra-Fire
Vai alla pagina of 28
R DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. HOT SURF ACES! Glass and other surfaces are hot during operation AND cool down. W ARNING Hot glass will cause burns.
3100-I ACT WOOD INSERT Page 2 September 1, 2008 R 250-6381D and Welcome to the Quadra-Fire Family ! H earth & Home T echnologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durability , and performance.
Page 3 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D SAFETY & OVER VIEW OF APPLIANCE Serial Number /Listing Label Location ------------------ 2 Dimensions -----------------------------------.
3100-I ACT WOOD INSERT Page 4 September 1, 2008 R 250-6381D INSERT DIMENSIONS T OP VIEW SIDE VIEW FRONT VIEW A B C L 27-7/16" (697mm) 14-1/8" (359mm) 38-7/8" (987mm) 12-3/16" (310m.
Page 5 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Hearth Extension A B C D F E Insert SideW all Maximum Mantel Depth - 10" (254mm) Fascia or T rim Mantel Thermal Protection USA & Can.
3100-I ACT WOOD INSERT Page 6 September 1, 2008 R 250-6381D A VOID FIRE: T o ensure that insulation or any other combustible material does not contact the chimney , a chimney inside the house must have at least 2 inches (51mm) of air space clearance around t he chimney .
Page 7 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D IF INST ALLING THIS MODEL TO A MASONR Y CHIMNEY , AL W A YS BE SURE THE CHIMNEY IS IN GOOD CONDITION AND THA T IT MEETS THE MINIMUM ST ANDARDS OF THE NA TIONAL FIRE PROTECTION ASSOCIA TION (NFP A) ST ANDARD 21 1.
3100-I ACT WOOD INSERT Page 8 September 1, 2008 R 250-6381D Floor Ceiling Caulk Floor (second Story) Non-Combustible Firestopping Material Minimum 1 inch (25mm) clearance from exterior chimney to shea.
Page 9 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D MASONR Y FIREPLACE USING DIRECT -CONNECT METHOD Refer to: Clearances to Combustibles on page 5, Canadian Installation requirements on page 1 1, Hearth Requirements on page 5 and Zero Clearance Adjustable Support Kit on page 14.
3100-I ACT WOOD INSERT Page 10 September 1, 2008 R 250-6381D The following modications of factory built replaces are permissible: 1) removal of damper; 2) removal of smoke shelf or bafe; 3) removal of ember catches; 4) removal of re grate; 5) removal of viewing screen/curtain; and, 6) removal of doors.
Page 1 1 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D INST ALLA TION IN CANADA MASONR Y and HEA T -CIRCULA TING (INST ALLA TIONS INTO F ACTORY -BUIL T FIREPLACES ARE PROHIBITED IN CANADA) Wheth.
3100-I ACT WOOD INSERT Page 12 September 1, 2008 R 250-6381D Vi ew of "L" Bracket installed Kit Includes: ( 2) Side Panels, left & right; (1) Panel T op & Fastener package; (2) Side T rim, left & right; (1) T rim T op & Fastener package.
Page 13 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Included in Kit: (2) Fan mounts & fan assemblies; (1) Speed Control, Power Cord/wire assembly; (1 set) Fan Connector wires, must be high temperature wire; and (1) Strain relief. T ools Needed: Large Phillips screwdriver , pliers F AN (BLOWER) INST ALLA TION INSTRUCTIONS Part No.
3100-I ACT WOOD INSERT Page 14 September 1, 2008 R 250-6381D ZERO CLEARANCE ADJUST ABLE TRIM SUPPORT , 2” to 10” Part No. 841-0990, size 9” x 45” and Part No.
Page 15 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D WOOD SELECTION AND STORAGE Burn only dry seasoned wood. Dry , well-seasoned wood will not only minimize the chance of creosote formation but will give you the most efcient heat output.
3100-I ACT WOOD INSERT Page 16 September 1, 2008 R 250-6381D BURN RA TES ST ARTING FIRE : Open both controls (push in) completely . After a wood load has been burning on high for 5 to 15 minutes or longer for very large pieces, close the Start-Up Air Control (right side) by pulling it out.
Page 17 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D AIR qUALITY AND YOUR qUADRA-FIRE INSERT In recent years there has been an increasing concern about the quality of our air . Much of the blame for poor air quality has been placed on the burning of wood for home heating.
3100-I ACT WOOD INSERT Page 18 September 1, 2008 R 250-6381D MAINTENANCE CARE AND CLEANING OF PLA TED SURF ACES IMPORT ANT : Y ou must clean all the ngerprints and oils from the plated surfaces before ring the insert for the rst time.
Page 19 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D BAFFLE REMOV AL & INST ALLA TION NOTE : The bafe in the 3100-I ACT Insert is 2700° Fiber Board.
3100-I ACT WOOD INSERT Page 20 September 1, 2008 R 250-6381D EXPLODED VIEW 1 9 10 11 2 4 3 8 6 7 5 Item Description Item Description 1 T rim Ring, Louver 7 Screen, Left/Right (interchange - able) 2 Ma.
Page 21 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Item # Part Description Alphabetical Order SKU 9 Bafe, Fiberboard 831-1800 10 Blanket, Ceramic, 1 inch thick 832-3401 Blower Assembly , w.
3100-I ACT WOOD INSERT Page 22 September 1, 2008 R 250-6381D 1 T rim Ring for Louver, Gold 430-2691 1 T rim Ring for Louver, Nickel 430-5430 Upgrade Kit to Nickel, Door UK-DRNL 14 W asher, Spacing SAE 3/8 for Door Handle 220-0010 Item # Part Description Alphabetical Order SKU ACCESSORIES 15 16 17 18 19 20 21 22 12 13 14 Item Description Part No.
Page 23 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Date of Service Performed By Description of Service Service And Maintenance Log.
3100-I ACT WOOD INSERT Page 24 September 1, 2008 R 250-6381D Date of Service Performed By Description of Service Service And Maintenance Log (Cont’d).
Page 25 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Homeowner ’ s Notes.
3100-I ACT WOOD INSERT Page 26 September 1, 2008 R 250-6381D W arranty Policy Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands ex.
Page 27 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or main- tenance of the.
Page 28 September 1, 2008 250-6381D R • Do NOT discard this manual. • Important operating and maintenance instructions included. • Read, understand and follow these instruci- tons for safe installation and operation. • Leave this manual with party responsible for use and operation.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Quadra-Fire 3100-I è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Quadra-Fire 3100-I - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Quadra-Fire 3100-I imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Quadra-Fire 3100-I ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Quadra-Fire 3100-I, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Quadra-Fire 3100-I.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Quadra-Fire 3100-I. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Quadra-Fire 3100-I insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.