Manuale d’uso / di manutenzione del prodotto Machined Aluminum Fixtures del fabbricante Profile
Vai alla pagina of 24
MA CHINED ALUMINUM FIXTURES RSA offers a collection of leading edge precision des ign ed ma ch in ed fi xt ur es f or u se w it h: • 60 A mp - 1 o r 2 Ci rc ui t Bus way • 2 0 Am p - 1 or 2 C ircu it T rac k • 4 0 Am p - 2 Ci rcui t / 2 Ne utra l T rack .
• YOKES CAN ROT A TE UP TO 370º WITHOUT REPOSITIONING THE FIXTURE DUE TO THE OVERCENTER MECHANISM. (BUSWA Y ONL Y) • AUTO-EXTENDING / RETRACTING LAMP HOLDER. LAMPS EXTEND FOR EASY RELAMPING AND RETRACT TO OPTIMUM POSITION. THIS IS EXTREMEL Y HELPFUL WHEN DEALING WITH V ARYING ACCESSOR Y OR LAMP DIMENSIONS.
32 MR11 12V MACHINED FIXTURES - Y OKE For use with 12V circuits only . CLOSED BACK OPEN BACK 4.95” 5.66” 4.09” 2.36” 3.27” C L 2.75” BUSWA Y SURFACE Closed Back Machined Fixture w/ Y oke P.
33 MR11 12V MACHINED FIXTURES - INTEGRAL TRANSFORMER For use with 120V or 277V circuits only . CLOSED BACK w/ INTEGRAL ELECTRONIC TRANSFORMER OPEN BACK w/ INTEGRAL ELECTRONIC TRANSFORMER 2.
34 MR16 12V MACHINED FIXTURES - Y OKE For use with 12V circuits only . CLOSED BACK OPEN BACK 3.35” 5.75” 3.72” 2.98” 6.46” 4.73” C L BUSWA Y SURFACE Closed Back Machined Fixture w/ Y oke P.
35 MR16 12V MACHINED FIXTURES - INTEGRAL TRANSFORMER For use with 120V or 277V circuits only . CLOSED BACK w/ INTEGRAL ELECTRONIC TRANSFORMER OPEN BACK w/ INTEGRAL ELECTRONIC TRANSFORMER 3.
36 AR70 12V MACHINED FIXTURES - Y OKE For use with 12V circuits only . CLOSED BACK OPEN BACK 7.51” 5.33” 4.34” 6.80” 4.59” 3.84” C L BUSWA Y SURFACE Closed Back Machined Fixture w/ Y oke P.
37 AR70 12V MACHINED FIXTURES - INTEGRAL TRANSFORMER For use with 120V or 277V circuits only . CLOSED BACK w/ INTEGRAL ELECTRONIC TRANSFORMER OPEN BACK w/ INTEGRAL ELECTRONIC TRANSFORMER 5.
38 AR111 12V MACHINED FIXTURES - Y OKE For use with 12V circuits only . CLOSED BACK OPEN BACK 6.07” 7.76” 5.07” 5.59” 8.46” 5.93” C L BUSWA Y SURFACE Closed Back Machined Fixture w/ Y oke .
39 AR111 12V MACHINED FIXTURES - INTEGRAL TRANSFORMER For use with 120V or 277V circuits only . CLOSED BACK w/ INTEGRAL ELECTRONIC TRANSFORMER OPEN BACK w/ INTEGRAL ELECTRONIC TRANSFORMER 2.17” 7.19” 4.66” 6.27” 1.06” 5.07” 5.59” C L C L 8.
40 P AR36 12V MACHINED FIXTURES - Y OKE For use with 12V circuits only . CLOSED BACK OPEN BACK 7.76” 5.07” 5.59” 8.46” 5.93” 6.08” C L BUSWA Y SURFACE Closed Back Machined Fixture w/ Y oke.
41 P AR36 12V MACHINED FIXTURES - INTEGRAL TRANSFORMER For use with 120V or 277V circuits only . CLOSED BACK w/ INTEGRAL ELECTRONIC TRANSFORMER OPEN BACK w/ INTEGRAL ELECTRONIC TRANSFORMER 7.19” 4.66” 2.17” 6.27” 5.07” 1.06” 5.59” C L 8.
42 P AR16 120V MACHINED FIXTURES - Y OKE CLOSED BACK OPEN BACK Closed Back Machined Fixture w/ Y oke PM621 cb - P AR16 for 60 Amp Busway PM121 cb - P AR16 for 20 Amp 1 circuit track PM221 cb - P AR16 for 20 Amp 2 circuit track PM421 cb - P AR16 for 40 Amp 2 cct / 2 ntrl track W attage 75 watt max.
43 CLOSED BACK OPEN BACK P AR20 120V MACHINED FIXTURES - Y OKE Open Back Machined Fixture w/ Y oke PM622 ob - P AR20 for 60 Amp Busway PM122 ob - P AR20 for 20 Amp 1 circuit track PM222 ob - P AR20 for 20 Amp 2 circuit track PM422 ob - P AR20 for 40 Amp 2 cct / 2 ntrl track W attage 50 watt max.
44 P AR30 120V MACHINED FIXTURES - Y OKE CLOSED BACK OPEN BACK Closed Back Machined Fixture w/ Y oke PM623 cb - P AR30 for 60 Amp Busway PM123 cb - P AR30 for 20 Amp 1 circuit track PM223 cb - P AR30 for 20 Amp 2 circuit track PM423 cb - P AR30 for 40 Amp 2 cct / 2 ntrl track W attage 75 watt max.
45 CLOSED BACK OPEN BACK P AR38 120V MACHINED FIXTURES - Y OKE Closed Back Machined Fixture w/ Y oke PM624 cb - P AR38 for 60 Amp Busway PM124 cb - P AR38 for 20 Amp 1 circuit track PM224 cb - P AR38 for 20 Amp 2 circuit track PM424 cb - P AR38 for 40 Amp 2 cct / 2 ntrl track W attage 250 watt max.
46 ES16 MET AL HALIDE MA CHINED FIXTURES CLOSED BACK W/ ST ANDARD BALLAST ENCLOSURE CLOSED BACK W/ T ALL BALLAST ENCLOSURE Closed Back Machined Fixture w/ Integral Ballast PM636 cb - ES16MH for 60 Amp.
47 CLOSED BACK W/ INTEGRAL ELECTRONIC BALLAST OPEN BACK W/ INTEGRAL ELECTRONIC BALLAST CDMR111 MET AL HALIDE MA CHINED FIXTURES Closed Back Machined Fixture w/ Integral Ballast PM637 cb - CDMR111MH fo.
48 P AR20 MET AL HALIDE MA CHINED FIXTURES CLOSED BACK W/ INTEGRAL ELECTRONIC BALLAST OPEN BACK W/ INTEGRAL ELECTRONIC BALLAST Closed Back Machined Fixture w/ Integral Ballast PM632 cb - P AR20MH for .
49 CLOSED BACK W/ INTEGRAL ELECTRONIC BALLAST OPEN BACK W/ INTEGRAL ELECTRONIC BALLAST P AR30 MET AL HALIDE MA CHINED FIXTURES Closed Back Machined Fixture w/ Integral Ballast PM633 cb - P AR30MH for .
50 P AR38 MET AL HALIDE MA CHINED FIXTURES CLOSED BACK W/ INTEGRAL ELECTRONIC BALLAST OPEN BACK W/ INTEGRAL ELECTRONIC BALLAST Closed Back Machined Fixture w/ Integral Ballast PM634 cb - P AR38MH for .
51 CLOSED BACK W/ INTEGRAL ELECTRONIC BALLAST T4 G8.5 MET AL HALIDE MA CHINED FIXTURES Closed Back Machined Fixture w/ Integral Ballast PM635 cb - T4G8.5MH for 60 Amp Busway PM135 cb - T4G8.5MH for 20 Amp 1 circuit track PM235 cb - T4G8.5MH for 20 Amp 2 circuit track PM435 cb - T4G 8.
52 T6 G12 MET AL HALIDE MA CHINED FIXTURES CLOSED BACK W/ INTEGRAL ELECTRONIC BALLAST 39W/70W Closed Back Machined Fixture w/ Integral Ballast PM638 cb - T6 G12MH for 60 Amp Busway PM138 cb - T6 G12MH.
53 PM632cb-39-AL-120 P AR20MH Machined Closed Back Integral Ballast PM613cbi-50-AL-120-S12 MR16 Machined Closed Back Integral T ransformer with 12” Stem PM624ob-250-AL P AR38 Machined Open Back with.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Profile Machined Aluminum Fixtures è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Profile Machined Aluminum Fixtures - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Profile Machined Aluminum Fixtures imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Profile Machined Aluminum Fixtures ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Profile Machined Aluminum Fixtures, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Profile Machined Aluminum Fixtures.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Profile Machined Aluminum Fixtures. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Profile Machined Aluminum Fixtures insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.