Manuale d’uso / di manutenzione del prodotto FCC 15 del fabbricante Powerware
Vai alla pagina of 32
Powerware Modbus Card User’s Guide ®®.
Class A EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with th e limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environm ent.
EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com i Table of Contents 1 Introduction 1 ......................................................... 2 Installing the Modbus Card 3 ........................................
TABLE OF CONTENTS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com ii.
EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 1 Chapter 1 Introduction The Eaton ® Powerware ® Modbus ® Card is an X - Slot ® connectivity device that allows you to continuously and reliably monitor the UPSs in your Building Management System (BMS).
INTRODUCTION EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 2 RS-485 Network Power Meter PLC UPS with Modbus Card Ethernet Gateway Building Management Software Ethernet -270.
EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 3 Chapter 2 Installing the Modbus Card The Modbus Card is available: S as a separate card for use with UPSs that have an X - Slot S factory - installed in a Powerware Expansion Chassis Use the following sequence for installing the Modbus Card: 1.
INSTALLING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 4 Four-Wire Communication The factory - default setting for the Modbus Card is for two - wire communication. To change the default setting, adjust the jumpers on the Modbus Card.
INSTALLING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 5 3. Change the J9 and J10 jumpers to the desired setting as shown in Figure 4. 1 1 J11 23456 ON S2 J7 J8 J10 J9 J9 J10 Four-Wire 1 1 J9 J10 Two-Wire (Default) 1 1 Figure 4.
INSTALLING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 6 Installing the Modbus Card into an X-Slot CAUTION To prevent electrostatic discharge (ESD), pl ace one hand on an unpainted metal surface such as the UPS rear panel.
EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 7 Chapter 3 Wiring the Modbus Card The Modbus Card provides an easy path for integrating a Powerware UPS into an RS - 485 Modbus network and also provides isolation of the communication between the UPS and the RS - 485 Modbus network.
WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 8 Four-Wire Networks The Modbus Card also supports four - wire, half - duplex, RS - 485 networks. Figure 7 shows a detailed view of four - wire connections using the Modbus Card terminal strip.
WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 9 For four-wire networks. All four RS -485 network signals including TxD(+), RxD(+), TxD(–), and RxD(–) must be connected to the terminal strip as illustrated in Table 1.
WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 10 3 8 7 9 1 6 2 4 5 Figure 9. RS-485 DB-9 Pin Numbers Table 2.
WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 11 1 J11 S2 J7 J8 J10 J9 RxD(–) Pull Down (620 Ω) RxD Terminator (120 Ω) Four-Wire Two.
WIRING THE MODBUS CARD EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 12 RS-232 Modbus Port It is also possible to use the RS - 232 Modbus port for connecting to your network. 3 8 7 9 1 6 2 4 5 Figure 11. RS-232 DB-9 Pin Numbers Table 3.
EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 13 Chapter 4 Modbus Card Configuration The Modbus Card has an RS - 232 configuration port that you can access with a terminal or a computer equipped with a terminal emulation program.
MODBUS CARD CONFIGURATION EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 14 2. Press [Enter]. The Configuration screen appears (see Figure 13).
MODBUS CARD CONFIGURATION EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 15 4. To configure the slave address, type AD followed by a space and node (1 through 247) and press [Enter]. The default is 29. This setting affects both RS - 232 and RS-485 Modbus connections.
MODBUS CARD CONFIGURATION EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 16.
EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 17 Chapter 5 Integrating the UPS Powerware provides a software tool named Modbus Profiler that creates a Modbus register map specifically for your Powerware UPS.
INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 18 5. Run profiler from the command prompt or double - click profiler.exe from Microsoft Windows Explorer. By default, Modbus Profiler uses the communication port specified in the [Connection] section of the profiler.
INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 19 Unit Format Value Name Register 113 Rectifier Input Status 1 BOOL Status 114 Bypass Status 0.
INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 20 Unit Format Value Name Register 162 Building Alarm 2 1 BOOL Status 163 Building Alarm 1 0 BO.
INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 21 Table 5. Read Input Registers - Modbus Function Code 04 (Input Registers Start at 30000) Reg.
INTEGRATING THE UPS EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 22 Unit Scale Meter Name Register 62 INVERTER VOLTS PHASE C /10 Volts 66 LOAD CURRENT PHASE A /.
EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 23 Chapter 6 Troubleshooting Problem Possible Cause Corrective Action The Modbus Profiler tool does not generate the f i l f i l The wrong communication port number was entered in the profiler comX command.
TROUBLESHOOTING EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 24 1 J11 2 13 4 5 6 ON S2 J7 J8 J10 J9 S2 Termination (Default ”OFF”) J11 Half Duplex Full-Duplex (Default) 1 1 J9 J10 Two-Wire (Default) 1 1 Two-Wire/Four-Wire J7 J8 DCE DCE/DTE (Default) 11 Figure 15.
TROUBLESHOOTING EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 25 Service and Support If you have any questions or problems with the Modbus Card, call your Local Distributor or the Help Desk at one of the following telephone numbers and ask for a Modbus Card technical representative.
TROUBLESHOOTING EATON Powerware ® Modbus ® Card User’s Guide S 164201376 Rev C www.powerware.com 26.
.
*164201376C* 164201376 C.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Powerware FCC 15 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Powerware FCC 15 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Powerware FCC 15 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Powerware FCC 15 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Powerware FCC 15, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Powerware FCC 15.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Powerware FCC 15. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Powerware FCC 15 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.