Manuale d’uso / di manutenzione del prodotto PR 199-100-3NV OR 3PV del fabbricante Polaris
Vai alla pagina of 32
1 This manual covers model numbers: United States Canada PG10* 34-100-2NV or 2PV PG10* 34-130-2NV or 2PV PG10* 50-130-2NV or 2PV PG10* 34-150-2NV or 2PV PG10* 50-175-3NV or 3PV PG10* 50-199-3NV or 3PV.
2 Y our safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
3 INST ALLA TION INSTRUCTIONS Consumer Information OBSERVE ALL GOVERNING CODES AND ORDINANCES. This water heater is design-certified by CSA International as a Category IV , direct vented water heater which takes its combustion air from the outside of the structure and exhausts all products of combustion to the outside of the structure.
4 Location Requirements The water heater design has been tested by CSA International and complies with ANSI Z21.10.1, Section 2.35 Flammable V apors Resistance. In garage installation avoid damage to your water heater by installing a vehicle stop as shown in figure below .
5 CONDENSA TE LINE Important: Do not run the condensate drain in areas that are likely to freeze. Frozen condensate will block the drain line and result in property damage or water heater malfunction.
6 Condensate Drain Line All parts of the condensate trap are glued except for the 1/2” CPVC drain stem joint at the elbow (see figure 3). This assembly can be turned with the outlet of the tee oriented as needed. Once orientation direction is decided, remove the unglued joint from the elbow at the bottom and apply a suitable cement to joint.
7 V ent Pipe Material The following plastic materials may be used for both the combustion air inlet and exhaust outlet piping subject to state and local codes: • Schedule 40 PVC or ABS • Schedule 40 or 80 CPVC • DWV Pipe is acceptable Note: Use only solid (not foam core) piping.
8 V ent T ermination Locations The air inlet and exhaust outlet must be installed with the following minimum clearances (see figure 6): • T welve inches above grade or maximum anticipated snow level. • T welve inches from any opening through which flue gases could enter the structure.
9 INLET/OUTLET VENT TERMINA TIONS (100,000 - 150,000 BTU/HR) Standard Horizontal T ermination When 3 inch pipe is used between the water heater and the outside wall, reduce it to 2 inch pipe before penetrating the wall. A maximum of 18 inches of 2 inch pipe may be used between the 3 inch transition and the inside of the wall (see figure 7A).
10 VERTICAL TERMINA TIONS (100,000 - 150,000 BTU/HR) When 3 inch pipe is used between the water heater and the roof, reduce it to 2 inch pipe before penetrating the roof. A maximum of 18 inches of 2 inch pipe may be used between the 3 inch transition and the inside of the roof.
11 CONCENTRIC VENT TERMINA TIONS (100,000 - 150,000 BTU/HR) For new installations, install 2” Concentric vent kit model KGA VT0501CVT , part number 6910542. See Manufacturer ’s instructions for complete installation or call customer service at 1-800-456-9805 for assistance.
12 INLET/OUTLET VENT TERMINA TIONS (175,000+ BTU/HR) Figure 8B: Alternative Horizontal T ermination (175,000+ BTU/Hr or greater input models) Figure 7B: Standard Horizontal T ermination (175,000+ BTU/.
13 VERTICAL TERMINA TIONS (175,000+ BTU/HR) Figure 9B: V ertical T ermination (175,000+ BTU/Hr models) For inputs of 175,000 BTU/Hr or greater , all termination pip- ing and fittings are 3”.
14 CONCENTRIC VENT TERMINA TIONS (175,000 + BTU/HR) Figure 10B: 3 Inch Concentric V ent For new installations, install 3” Concentric vent kit model KGA VT0601CVT , part number 6910543. See Manufacturer ’s instructions for complete installation or call customer service at 1-800-456-9805 for assistance.
15 Figure 14: Input Graph Gas Input Rate The gas input rate of this water heater is affected by several environmental factors such as: • The heating value of the gas • The air and gas densities (w.
16 Figure 15: T ypical One-T emperature System Piping Installation T empering V alve Installation A tempering valve has been provided for use with the Polaris® Gas water heater and must be installed, per the manufacturer ’s instructions, in the domestic hot water line.
17 • If the space heating system requires water temperatures in excess of 120°F , a tempering valve (provided) must be installed per the manufacturer ’s instructions in the potable hot water supply to limit the risk of scald injury . • Pumps, valves, piping and fi ttings must be compatible with potable water .
18 T emperature and Pressure Relief V alve For protection against excessive pressures and tempera- tures, a temperature and pressure relief valve must be installed in the opening marked “T & P RELIEF V AL VE”.
19 GAS SUPPL Y AND PIPING Gas Requirements Read the data plate to be sure the water heater is made for the type of gas being used. This information will be found on the data plate located on the front of the water heater . If the information does not agree with the type of gas available, do not install or operate the water heater .
20 Gas Pressure T esting Important : This water heater and its gas connection must be leak tested before placing the appliance in operation. • If the code requires the gas lines to be tested at a pressure of 14” W .
21 Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.
22 WIRING DIAGRAM MODELS 130,000 BTU/Hr & Below NOTICE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH 18 GAUGE STRANDED 105C WIRE OR ITS EQUIV ALENT .
23 INST ALLA TION CHECKLIST W ater Heater Location Requirements Centrally located with the water piping system. Located as close to the gas piping and vent pipe system as pos- sible. Located indoors and in a vertical position. Protected from freezing temperatures.
24 OPERA TING YOUR W A TER HEA TER Read and understand these directions thoroughly before attempting to operate the water heater (see Operating Instructions on page 25). Check the data plate on the front of the water heater for the correct gas. Do not use this water heater with any gas other than the one listed on the data plate.
25 Stacking Stacking occurs when a series of short draws of hot water (3 gallons or less) are taken from the water heater tank. This causes increased cycling of the burner and can result in increased water temperatures at the hot water outlet. A tempering valve must be installed in the hot water supply line to reduce the risk of scald injury .
26 OPERA TIONAL CONDITIONS MAINTENANCE W ater Heater Sounds During the normal operation of the water heater , sounds or noises may be heard. These noises are common and may result from the following: 1. Normal expansion and contraction of metal parts during periods of heat-up and cool-down.
27 MAINTENANCE OF YOUR W A TER HEA TER 3 Month Inspection At least every 3 months, a visual inspection should be made of the combustion air inlet as well as the exhaust and water piping. Check the water heater for the following: • Obstructions, damage, or deterioration in the venting system.
28 TROUBLESHOOTING Ignition Control Module (ICM) LED Error Codes: (Flashes visible through viewport in access door) FLASHES INDICA TED PROBLEM CONTROL REACTION 1 Pressure Switch Closed SC* 2 Pressure .
29 SOFTW ARE OPERA TION SEQUENCE IGNITION CONTROL MODULE SOFTW ARE OPERA TION SEQUENCE * For 175,000 BTU/Hr models and above the flame establishing period is six seconds.
30 REP AIR P ARTS LIST/DIAGRAM ITEM NO. P ARTS DESCRIPTION 1 1” NPT x 3” BRASS NIPPLE 2 THERMOST A T SENSOR BUSHING 3 O-RING 4 THERMOST A T SENSOR/ECO 5 INVERTED FLARE NUT 6 PLUG 7 VINYL TUBING 8 PRESSURE SWITCH 9 COMBUSTION BLOWER 10 4 INCH DIAMETER BLOWER GASKET 11 BURNER (NA TURAL AND L.
31 REP AIR P ARTS LIST/DIAGRAM ITEM NO. P ARTS DESCRIPTION 1 1-1/2” NPT x 3” BRASS NIPPLE 2 THERMOST A T SENSOR BUSHING 3 THERMOST A T SENSOR/ECO 4 CONTROL P ANEL HOUSING 5 IGNITION CONTROL 6 BLOW.
32 POLARIS MODELS & DIMENSIONS C lea n-out P ort MODEL NUMBER GAL. CAP . INPUT (MBTU PER HR.) VENT DIA. EXTERIOR W A TER CONNECTIONS T&P HGT GAS SUPPL Y AIR INLET/ EXHAUST APPROX SHIP .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Polaris PR 199-100-3NV OR 3PV è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Polaris PR 199-100-3NV OR 3PV - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Polaris PR 199-100-3NV OR 3PV imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Polaris PR 199-100-3NV OR 3PV ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Polaris PR 199-100-3NV OR 3PV, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Polaris PR 199-100-3NV OR 3PV.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Polaris PR 199-100-3NV OR 3PV. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Polaris PR 199-100-3NV OR 3PV insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.