Features • W ake-up Function for a Microcontr oller with Preamble Detection • 1m V rms Sensitivity • 1 µA Standby Current • P ower Supply: 2V to 3.8V • Baud Rate: up to 4 kb ps (ASK Modulation) • Operation T emperature: up to 125°C • Withstan ds +175°C • Few External Components Application • Tire Pressure Mo nitoring (TPM) 1.
2 4598H–AUTO–03/07 ATA5283 2. Pin Configuration Figure 2-1. Pinning TSSOP8 L VDD 3 4 2 1 N_DATA N_WAKEUP RESET COIL 8 7 6 5 TST2 TST1 VSS Figure 2-2.
3 4598H–AUTO–03/07 ATA5283 3. Functional Description The ATA5283 is an ultra-low pow er ASK receiver. Without a carr ier signal it operates in the standby listen mode.
4 4598H–AUTO–03/07 ATA5283 3.3 A utomatic Gain Control For a correct demodulation the signal conditione r needs appropriate interna l signal amplitude. To control the in put signal the ATA52 83 has a build in dig ital AGC. The gain control circuit regu- lates the internal signal amplitude to the reference value (Ref2, Figure 3-2 ).
5 4598H–AUTO–03/07 ATA5283 3.4 Signal Conditioner The signal conditioner d emodulates the amplifier outp ut signal and conver ts it to a binary signal.
6 4598H–AUTO–03/07 ATA5283 Figure 3-5. Turn Off Delay Time (t off ) versus Antenna Q- Factor 3.5 Data Output The data output N_DATA outputs the demodulated and digitized LF signal according to the envelope of the ante nna input signal. In the standby mode the N_DATA ou tput is disabled and set to level 1.
7 4598H–AUTO–03/07 ATA5283 3.8 Standb y Listen Mode In the standby listen mode the IC monitors the co il input with a very low current consumption. The automatic gain control is switched off and the gain is set to the maximum value. The N_DATA and the N_WAKEUP outp ut are set to a high level.
8 4598H–AUTO–03/07 ATA5283 Figure 3-7. Pin Connection an d Pin Protection Figure 3-8. Coil Input Impe dance 2 k Ω Divider impedance 143 k Ω to 5 M Ω 2 k Ω 7 VDD VDD N_W AKEUP N_D A T A RES.
9 4598H–AUTO–03/07 ATA5283 4. Absolute Maxim um Ratings Stresses beyond those listed under “Absolute Maximum Ratings” may cause per manent damage to the device.
10 4598H–AUTO–03/07 ATA5283 7. Electrical Characteristics V SS = 0V , V DD = 2V to 3.8V , T amb = –40 ° C to +105°C, characterized up to 125°C , unless other specified No. Parameter s T est Conditions Pin Symbol Min. T yp. Max. Unit T ype* 1 P ower Supply and Coil Limiter 1.
11 4598H–AUTO–03/07 ATA5283 3 Automatic Gain Control 3.1 Preamble detection time V IN ≥ 3m V rms at 125 kHz t DAGC 19 2 P er iods B 3.2 AGC adjustment time f = 125 kHz V IN = 1 mV rms V IN = 3 mV rms V IN = 30 mV rms V IN = 100 mV rms V IN = 1V rms t AGC t AGC t AGC t AGC t AGC 0 48 220 292 450 512 P er iods C 3.
12 4598H–AUTO–03/07 ATA5283 9. P acka g e Inf ormation 8. Or dering Information Extended T ype Number P acka ge Remarks A T A5283P-6AQJ TSSOP8L 5000 pieces, taped and reeled, Pb-free A T A5283P-6APJ TSSOP8L 500 pieces, taped and reeled, Pb-free 3 ±0.
13 4598H–AUTO–03/07 ATA5283 10. Revision History Please note that the follo wing page numbers referred to in this section re f er to the specific revision mentioned, not to this document.
Disclaimer: The information in this d ocument is provided in conn ection with Atmel products. No license, ex press or impli ed, by estoppel or otherwise, to any intellectual proper ty r ight is granted by this document or in connection with the sale of Atm el products.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Atmel ATA5283 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Atmel ATA5283 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Atmel ATA5283 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Atmel ATA5283 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Atmel ATA5283, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Atmel ATA5283.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Atmel ATA5283. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Atmel ATA5283 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.