Cat 5 USB 2.0 Extender UEH4002 User Guide www.aten.com.
UEH4002 User Manual ii Thank you fo r purchasing t he UEH4002. Please read this guide thoroug hly. F eder al Communic a tion Commis sion Interference St a tement This equipment has been tested and foun d to comply with the limits for a Class B digital service, pursuant to Part 15 of the FCC rules.
UEH4002 User Manual iii Content s Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 UEH4002 Product Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Requirements .
1 Introduction The instructions in this guide assume a gene ral knowledge of computer installation procedures, familiarity with cabling r equirements, and some understanding of USB devices. UEH4002 Product Contents Your UEH4002 is packaged with: UEH4002LUSB 2.
UEH4002 User Manual 2 The UEH4002L The Local unit connects to the computer usi ng a standard USB cable. Power for this unit is provided by the USB on the host computer. ITEM TYPE DESCRIPTION 1 Power LED (Blue) LED turns on when powe r is supplied. Off when no power is supplied.
UEH4002 User Manual 3 The UEH4002R The Remote unit provides USB Type A ports for standard USB devices. It allows you to connect up to four USB devices directly. Additional devices may be connected by attaching USB hubs to the Remote unit. T he Remote unit is powered by an external AC adapter and can supply up to 500 mA to each USB port.
UEH4002 User Manual 4 7 Power Port Connects to the AC power supply . Required at Remote for proper operation. 8 Link Port (RJ45) Accepts RJ45 connec tor for Cat 5 cabling (or better).
UEH4002 User Manual 5 Inst alla tion Guide USB extension up to 100m Cat 5 (or better) cable. Before you can install the UEH4002, you need to prepare your site: 1. Determine where the computer is to be located and set up the computer . 2. Determine where you want to locate the USB device(s).
UEH4002 User Manual 6 Connecting the Lo cal unit to the R emote unit Note: To ensure proper operation, it is recommended that only Cat 5 or better, Unshielded Twisted Pair (UTP) cabling be used to co nnect the Local unit to the Remote un it.
UEH4002 User Manual 7 Connecting a USB Device 1. Install any software required to operate the USB device(s). Refer to the documentation for the USB device(s), as requir ed. 2. Connect the USB device to the device port on the Remote unit. 3. Check that the device is detected and installed properly in the operating system.
UEH4002 User Manual 8 Link LED on Local unit is on, Host LED on Local unit is off. The host computer is not power ed on. The Local unit is not connected to the computer (when used with the optional Local AC adapter). The computer does not support USB hubs.
UEH4002 User Manual 9 USB device is attached to Remote USB port but Remote device LE D is off . • A USB device must have the appropriate driver installed on the computer operating system. 1. Install the required USB device driver on the computer operating system prior to attaching the USB device to the Remote unit.
UEH4002 User Manual 10 Specific a tions Range 330 feet (100 meters) over Cat 5e (or better ) cable USB device support High-speed de vices (480 Mb/s) (USB 2.0) Full speed devices (12 Mb/s) (USB 2.0 & 1.1) Low speed devices (1.5 Mb/s) (USB 2.0 & 1.
UEH4002 User Manual 11 Limited Hardware W arr anty ATEN warrants that any hardware products accompanying this document ation shall be free from significant defects in material and workmansh ip for a period of one year from the date of purchase. ATEN’s hardware warranty extends to Licensee, its customers, and end users .
UEH4002 User Manual 12 Obt aining W arranty Ser vice To obtain warranty service, you must contact ATEN within the warran ty period for a Return Material Authorization (RMA) number. ATEN will not accept returns without an authorized RMA number. Be sure you have t he serial numbers of the Local unit and Remote unit before calling.
UEH4002 User Manual 13 Tec h n i cal G l o ssary Category 5 (Cat 5) Network Cabling Category 5 cable is commonly also referred to as Cat 5. This cabling is available in either solid or stranded twisted pair copper wire variants and as UT P (Unshielded Twisted Pair) or STP (Shielded Twiste d Pair).
UEH4002 User Manual 14 T a ble 2 - T568B W iring PIN P AIR WIRE CAB LE COLOR 1 2 1 WHITE/O RANGE 2 2 2 ORANGE 33 1 W H I T E / G R E E N 41 2 B L U E 51 1 W H I T E / B L U E 6 3 2 GREEN 7 4 1 WHITE/B.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il ATEN Technology UEH4002 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del ATEN Technology UEH4002 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso ATEN Technology UEH4002 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul ATEN Technology UEH4002 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il ATEN Technology UEH4002, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del ATEN Technology UEH4002.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il ATEN Technology UEH4002. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo ATEN Technology UEH4002 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.