MS500 Series Manual Switchers Installation/ Operation Manual C820M-D (1/01) Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 or .
2 Pelco Manual C820M-D (1/01) CONTENTS Section Page IMPORT ANT SAFEGUARDS AND WARNINGS ................................................................ 3 DESCRIPTION .....................................................................................
Pelco Manual C820M-D (1/01) 3 IMPOR T ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
4 Pelco Manual C820M-D (1/01) DESCRIPTION The MS500 Series provides an inexpensive and reliable method of switching 4 to 18 inputs to a single monitor output using interlocked manual pushbuttons. Included in this series is the MS540 switcher with two monitor outputs and the capacity to switch up to 40 inputs with a 14 pushbutton panel.
Pelco Manual C820M-D (1/01) 5 INST ALLA TION 1. Place the unit on a flat surface, or install it in an equipment rack using the appropriate rack-mount kit. 2. Refer to Figures 1 - 6 and select the desired configuration for your installation. Make all equipment connections as illustrated in the drawings.
6 Pelco Manual C820M-D (1/01) LOOPING SWITCHERS Use coaxial cable to connect the input and looping video cables to the appropriate input connectors. Connect the monitor(s) to the monitor output. (Refer to Figures 3 and 4.) IMPORT ANT : Looping switchers do not have inter- nal termination.
Pelco Manual C820M-D (1/01) 7 SWITCHERS WITH AUDIO FOLLOW MS500 Series models with “AF” in the suffix have a connection for an audio signal source. Using appropriate cable with compatible connectors, connect audio signal sources to RCA jack (refer to Figure 5).
8 Pelco Manual C820M-D (1/01) SWITCHERS WITH AMPLIFIED OUTPUT The MS540DT and MS540LDT switchers provide both an amplified output (Monitor 1) and a non-amplified output (Monitor 2). Most installations require the use of Monitor 2 output for proper operations.
Pelco Manual C820M-D (1/01) 9 Figure 7. Schematic for 4-18 Position Manual Switchers TYPICAL CONNECTION FOR LOOPING F 1 A C INPUT 1/16 AMP 1 2 3 BLK/RED BLK/GRN BLK/YEL BLK YEL GRN/YEL GRN RED BLU GR .
10 Pelco Manual C820M-D (1/01) SPECIFICA TIONS VIDEO Inputs: 4, 8, 12, or 40 as indicated by the last two digits of the model number. Video Connectors: BNC Audio Connectors: AF Switchers 1/8-inch RCA .
Pelco Manual C820M-D (1/01) 11 GENERAL Switching: Interlocked manual pushbuttons Construction: Cover Steel, black polyester powder coat Chassis Steel, zinc plated Panel Aluminum, black polyester powder coat Environment: 32 ° to 120 ° F (0 ° to 48.89 ° C) Dimensions MS504 Series (except AFL, BAF, and BAF models): 1.
12 Pelco Manual C820M-D (1/01) REVISION HISTOR Y Manual # Date Comments C820M 3/88 Original version. C820M-A 9/90 Added to W arning Section for UL compliance. C820M-B 6/92 Revised to cover all MS500 Series models. Added DT200 to Options section. C820M-C 10/97 Revised Figures 1 and 2.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Pelco MS504AFL è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Pelco MS504AFL - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Pelco MS504AFL imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Pelco MS504AFL ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Pelco MS504AFL, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Pelco MS504AFL.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Pelco MS504AFL. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Pelco MS504AFL insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.