® INST ALLA TION F T82011/FR82011 Ethernet Media Converter One 10BASE-T/100BASE-TX Port and One 100BASE-FX Fiber Port C2653M (6/07).
.
C2653M (6/0 7) 3 Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Not ices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 C2653M (6/07) Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with dry cloth. 7. Do not block any ventilation openings.
C2653M (6/0 7) 5 The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
6 C2653M (6/07) Regulatory Notices This device complies with Part 15 of the FCC Rule s. Operation is subject to the following two conditions: (1) this device may not cause harmful in terference, and (2) this device must accept any interference received, including interfer ence that may cause undesired operation.
C2653M (6/0 7) 7 Product Overview DESCRIPTION The F T82011/FR82011 Ethernet media co nverter co n ve r ts 10 B AS E -T / 100BASE-TX data to 100BASE-FX data and vice versa. Designed for point -to-point applica tions, the F T82011/F R 82011 me d ia c on v er t er provides one 10BASE-T/100BASE-TX port and one 100BASE-FX fiber port.
8 C2653M (6/07) • Compatible with ot her Ethernet equipment: – 10BASE-T/100BASE-TX compat ibility with all Pelco © and third-pa rty 10BASE-T/ 100BASE-TX Ethernet devices – Fiber optic compatibi.
C2653M (6/0 7) 9 MODELS The F T82011 and FR82011 modules consist of the following se ries of models: Multimode Models:* F T82011MSTR-1 Ethernet media converter , one 10 BASE-T/100BASE-T X port, one mu.
10 C2653M (6/07) FRONT PANEL Figure 2 illustrates the front panel of the F T82011 and FR82011 modules. Figure 2. Front Panel of F T82011 and FR82011 Modules For detailed information about the front-panel LEDs, refer to the T roubleshooting section.
C2653M (6/0 7) 11 REAR PANEL Figure 3 illustrates the rear pa nel of the F T82011 and FR82011 modules. Figure 3. Rear Panel of F T82011 and FR82011 Mo dules (SC Fiber Connector Shown) For additional informati on about rear -panel connections, refer to the Installation section.
12 C2653M (6/07) Installation PACKAGE CONTENTS The following it ems are supplied: 1 F T82011 or FR82011 module 1 Regulated switching power suppl y with four plug adapt ers (North American, Australian, U.K., and European configurations); 100-240 V A C, 50-60 Hz input, 12 VDC output 1 Wall clip with two 4 -40 x 0.
C2653M (6/0 7) 13 Using the TX Mode switch, you can do the following: • Enable autonegotiation or select (force) a specific data rate and duplex mode: – Enabling autonegotiation allows the F T8201.
14 C2653M (6/07) MOUNTING The F T82011/FR82011 module can be mounted into a ra ck or can be used as a stand-alone module. As a stand-alone module, the un it can be placed on a desktop or can be mounted to a wall.
C2653M (6/0 7) 15 Mounting the F T82011/FR82011 Module Using the Wall Clip NOTE: Before mounting the F T82011/FR82011 module to a wall, ensure that there is adequate space at both ends for viewing the front-panel LEDs and for making the various rear-pa nel cable connections.
16 C2653M (6/07) CONNECTIONS Connections to the F T82011/FR82011 module are made on the rear panel of the unit (refer to Figure 6). Figure 6. F T82011/FR82011 Module Connecti ons As illustrated in Fig.
C2653M (6/0 7) 17 • Fiber connection NOTE: Fiber port A of the F T82011 module connects to fiber port B of the FR82011 module or of any other Pelco Ethernet sw itch that supports wavelength division multiplexing (WDM).
18 C2653M (6/07) T roubleshooting LED indicators on the front and rear panels of the F T82011/FR82011 module allow you to monitor operational status: • LED indicators on the front panel allow you to monitor operating power , 100BASE-FX port status, and optic signal/l aser status.
C2653M (6/0 7) 19 100BASE-FX Status LED ( ) (Continued) Red Ethernet link is down. NOTE: In addition to a red 100BASE-FX Status LED, the Optic Fault LED is green or flashing red and the left RJ-45 Port Status LED (Link/Activity) is not lit .
20 C2653M (6/07) Optic Fault LED ( ) (Continued) Red Ethernet link is down. NOTE: In addition to a red Optic Fault LED, the 100BASE-FX LED and the left RJ-45 Port Status LED (Link/Activity) LED are not lit.
C2653M (6/0 7) 21 Optic Fault LED ( ) (Continued) Flashing red Ethernet link is down. NOTE: In addition to a flashing red Optic Fault LED, the 100BASE-FX LED is red and the left RJ-45 Port Status LED (Link/Activity) LED is not lit.
22 C2653M (6/07) T able C. T roubleshooting with Rea r-Panel Indicators Indicator Color Meaning Possible Cause Corrective Action RJ-45 10BASE-T/100BASE-TX Port St atus LED - Left (Link/Activity) Amber A 10BASE-T link is estab- lished. — If 10BASE-T operation is desired, no action is required.
C2653M (6/0 7) 23 RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued) Not lit Ethernet link is down. A link-down det ection condition exists due to any of the following fault .
24 C2653M (6/07) RJ-45 10BASE-T/100BASE-TX Port Stat us LED - Right (Duplex/Co llision) Amber Port is set to 10BASE-T full-duplex mode. — If 10BASE-T full-duplex operation is desired, no action is required.
C2653M (6/0 7) 25 RJ-45 10BASE-T/100BASE-TX Po rt Status LED - Right (D uplex/Collision) (Continued) Green Port is set to 100BASE-TX full-duplex mode. — If 100BASE-TX full-duplex operation is desired, no action is required.
26 C2653M (6/07) RJ-45 10BASE-T/100BASE-TX Po rt Status LED - Right (D uplex/Collision) (Continued) Not lit Por t is set to 10BASE-T half-duplex mode and no collisions are detected.* — If 10BASE-T half-duplex operation is desired, no action is required.
C2653M (6/0 7) 27 Specifications PERFORMANCE Switch T ype Unmanaged Layer 2 Switch Method Store and forward Data Rate 10/100 Mbps Compliance IEEE 802.3, 802.3u, 802.3x Interface Auto MDI/MDI-X Operating Mode Full- duplex or half-duplex Address T able Size 1,024 MAC address ent ries with automatic learning and aging Quality of Service IEEE 802.
28 C2653M (6/07) OPTICAL POWER BUDGET AND MAXI MUM TRANSMISSION DIST ANCE Model Number Wavelength (T ransmit/Receive)* Optical Power Budget Maximum T ransmission Distance T ransmitter End Receiver End Fiber Port A Fiber Port B Multimode (62.5/125 μm) F T82011MSTR-1 FR82011MSTR-1 1310/850 nm 850/1310 nm 26 dB † 2 km (1.
C2653M (6/0 7) 29 Appendix. RJ-45 Connector Pinouts Figure 7 illustrates RJ-45 MDI/MDI-X connector pinouts. Figure 7. RJ-45 MDI/MDI-X Connector Pinouts T able D summarizes RJ-45 MDI/MDI-X connector pinouts.
30 C2653M (6/07) The materials used in the manufacture of this document and its components are compliant to t he requirements of Directive 2002/95/EC. This equipment contains electrica l or electronic.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merc handise pr oved defective in mate rial or work manship for a period of one year after the date of shipment.
® Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Pelco FR82011 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Pelco FR82011 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Pelco FR82011 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Pelco FR82011 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Pelco FR82011, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Pelco FR82011.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Pelco FR82011. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Pelco FR82011 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.